IMPORTANT!
PLEASE MAKE THIS INFORMATION AVAILABLE TO YOUR JOINER AS IT COULD REDUCE YOUR INSTALLATION COST.
Fisher & Paykel
INSTALLATION INFORMATION
Built-In Ovens
BI601 Series - Built-In Oven
BI601XC2 Series - Built-In Oven/Microwave Combination
BI451 Series - Built-In Compact Oven
CAUTION: In order to avoid a hazard these appliances must be installed
according to these Installation Instructions.
Please follow installation information carefully.
If in doubt consult your local building authority by-laws.
BEFORE YOU START
DO Ensure a suitable disconnection switch is incorporated in the permanent wiring,
mounted and positioned to comply with the local wiring Rules and Regulations.
DO Ensure that the location of the Oven connection socket is outside the installation
space if the appliance is flush to the rear wall.
DO Ensure the benchtop and the Oven cavity are square and level.
DO Ensure the electrician allows as least 1.5m free length of connection cable within the
cavity for ease of installation and service of the Oven.
DO Use easy to clean finishes for the wall surfaces surrounding the Oven and Cooktop to
aid removal of any cooking fume staining resulting from use of the Oven and Cooktop.
DO Ensure that the interconnection cord between the Cooktop and the Oven is not
accessible via cupboard doors after installation. This applies to any extension cords as well, even though they are double insulated.
DO Consult local building authorities and by-laws if in doubt regarding installation.
DO Check the height from the floor suits the user.
DO Ensure the cavity is a completely sealed box with no gaps. This will ensure the
cooling air flows under the product to give the correct venting and cooling for the oven and cabinet surround.
Page 1
BUILT-IN OVEN INSTALLATION INSTRUCTIONS
1. Check that the kitchen cavity is square and within the limits in the INSTALLATION DIMENSIONS.
2. Lift oven and slide into place. Secure Oven in cavity using 4 'wood screws' and washers supplied through enamelled frame at either side of oven as shown in Flush Fitting Installation Diagram.
3. Check that the Oven is firmly secured in the kitchen unit.
4. When installing the oven it is essential to centre the product in the cavity giving a spacing of 2.5mm from the door edge to the joinery.
NOTE: If installing a Cooktop above the Oven ensure adequate clearance is provided for
the Cooktop as per the Cooktop Manufacturer's Instructions.
If installing a BI601 Single Built-In Oven with Wall Trim Kit, ensure you use instructions that accompany that kit, Part No. 447915.
Flush Fitting
Installation Diagrams
Cabinetry adjacent to ovens must have a minimum temperature rating of 90°C as stated in AS/NZS 3350.2.6
Page 2
Height Recommendation Guide
Figures are based on an average height of 1650mm (5'5") wearing shoes.
The height of the product may vary + 50mm according to the height of the most frequent user.
Page 3
BI601 Series - Built-In Oven
Overall Overall
Width Height Depth
Oven Dimensions 595mm 595mm 562mm Cabinet Dimensions 568mm 585mm 550mm Please Note: Oven front dimensions differ from cabinet dimensions.
Product Dimensions
Top View
Side View