Fisher & Paykel DS603, DS6031, DD603, DD6031 User Manual

0 (0)

US CA

part number 526607 N 05/2005 (page 1 of 12)

R

INSTALLATION INSTRUCTIONS

(NOTE: FOR INTEGRATED PANEL PREPARATION INSTRUCTIONS REFER TO SUPPLIED SHEET)

DOUBLE DD603 MODELS

DD603 PREFINISHED (shown left) DD603 FLAT DOOR (not shown) DD603I INTEGRATED (shown right)

SINGLE DS603 MODELS

DS603 PREFINISHED (shown left) DS603 FLAT DOOR (not shown) DS603I INTEGRATED (shown right)

NOTE TO THE INSTALLER

1.Read these instructions completely and carefully.

2.Installation of this DishDrawer® requires basic mechanical and electrical skills.

3.Be sure to leave these Instructions with the Customer.

4.At the completion of the DishDrawer® installation, the Installer must perform Final Check List as per Section 12 of these Installation Instructions.

5.Remove all packaging materials supplied with the DishDrawer®.

6.This dishwasher is manufactured for indoor use only.

WARNING!

Before installing the DishDrawer® , remove the house fuse or open the circuit breaker. Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations.

Important!

These instructions must be followed precisely to ensure correct venting and operation of the DishDrawer® . In the event of a fault related to the incorrect installation, the installer will be liable for any repairs.

Important!

The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required.

NOTE TO THE CUSTOMER

Keep these Installation Instructions with your User Guide for future reference. The DishDrawer® must be securely anchored before it is operated.

Important!

Improper installation is not covered under the Warranty.

Important!

If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage.

R

BEFORE YOU START - DOUBLE & SINGLE MODELS

PARTS SUPPLIED

DOUBLE MODELS

Flexible Extrusion

Flexible Extrusion

Installation Tabs (2)

for Sides (2)

for Top (1)

Edge Protector (1)

Clamp

 

 

(1)

Washer

Phillips 16mm

 

 

 

 

 

(1)

Screws (7)

 

 

 

Moisture

Drain Hose

Drain Hose

Wire

Protection

Tape (1)

Support (1)

Joiner (1)

Clips (2)

p/n 527208

 

 

 

Prefinished

Toe Kick (1)

White prefinished toe kick kit p/n 526678 or Black prefinished toe kick kit p/n 526679

or Iridium prefinished toe kick kit p/n 527109

SINGLE MODELS

Wire

Edge

Clip (1)

 

Protector (1)

Drain Hose

Support (1)

Drain Hose

Joiner (1)

Flexible Extrusion for Sides (2)

Clamp (1)

 

Phillips 16mm

Screws (5)

Moisture Protection Tape (1) p/n 527208

Washer (1)

TOOLS NEEDED

Wooden Chopping Board

Drill & No.2 Phillips Bit

Tape Measure

No.2 Phillips Screwdriver

Spirit Level

Flat Screwdriver

Safety Glasses

Adjustable Wrench or M5 Socket

Utility Knife

Ø11/2” (38mm) Hole Saw

Pencil

Side Cutting Pliers

Sandpaper

 

SPARE PARTS INSTALLATION KIT FOR SINGLE & DOUBLE MODELS: p/n 526676

INSTALLATION PREPARATION

ELECTRICAL PREPARATION

A)The switched power outlet must be outside the DishDrawer® cavity so that it is accessible after installation.

B)The switched power outlet must be between 6” (150mm) and 18” (450mm) from the DishDrawer® cavity.

C)Refer to Page 9, Step 5 for electrical connection options.

Important!

The services hole in the DishDrawer® cavity needs to be large enough for the plug on the power supply cord to fit through, but MUST NOT be more than 11/2” (38mm).

PLUMBING & DRAINAGE PREPARATION

A)A readily accessible valve must be installed in the water supply pipe.

B)If the supply pressure exceeds 145 psi (1000kPa), then a pressure limiting valve must be used.

C)Review Plumbing Options on pages 4 or 6. Choose a method that best suits your needs.

D)A Drain Hose extension Kit P/N 525798 will extend the drain hoses by 1413/4” (3.6m). The kit is available from the nearest Fisher&Paykel Authorized Service Agent. DO NOT extend beyond this limit.

E)This Dishwasher’s maximum drain height is 371/2” (950mm).

CAVITY PREPARATION

A)It is recommended that all cabinetry surrounding the DishDrawer® (including the underside of the countertop) is sealed with an oil based paint or moisture-proof polyurethane to prevent possible steam

damage. The air in the cavity can get very hot and humid (saturated at 122oF/50oC)

B)The self-adhesive moisture protection tape must be applied to the underside of the countertop to prevent moisture damage, (refer to cavity diagram pg 3 or 5). Be sure surfaces are dry and dust-free prior to application.

C)Be sure the cavity provides sufficient material to secure the DishDrawer® using the mounting tabs (refer to step 1, page 7). If there is

nothing to screw to, add a brace. See page 3 or 5 for screw locations.

D)The services hole MUST be immediately adjacent to the rear lower corner of the cabinetry. If not, the hoses will prevent the DishDrawer® being pushed back into the cavity all the way. The hole can be located on either side depending on the location of the services.

E)Be sure the cavity sides are plumb (vertical) as this will assist with levelling the DishDrawer® .

F)Minimum clearances:

1/8(2.5mm)

1/8(2.5mm)

1/2(13mm)

ELECTRICAL INFORMATION

POWER SUPPLY CORD

A)Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord.

B)If the power supply cord is damaged, it must be replaced by

the Manufacturer, Service Agent or a similarly qualified person in order to avoid a hazard.

GROUNDING INSTRUCTIONS

A)This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

WARNING!

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly grounded.

B)This appliance is equipped with a power supply cord having an equipment-grounding conductor and an earthing plug. The power supply plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local Codes and Ordinances.

WARNING!

Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adaptor plug or multiple outlet box.

2

DOUBLE MODELS

SERVICES SPECIFICATIONS

WATER CONNECTION

Recommended HOT (Maximum 140°F/60°C).

Supplied hose to suit 3/8” (9mm) male compression fitting.

WATER SOFTENER MODELS

Refer to your DishDrawer® User Guide for how to set up your water softener.

WATER PRESSURE

Maximum

Water Softener Models

145 p.s.i. (1000kPa)

Other Models

145 p.s.i. (1000kPa)

DRAIN CONNECTION

 

w NN

 

NN

w

 

 

 

 

 

 

 

w

 

 

 

 

 

 

 

Minimum

14.5 p.s.i. (100kPa)

4.3 p.s.i. (30kPa)

Drain Hose Joiner to suit Ø3/4” ± 5/64”, Ø5/8” ± 5/64” and Ø1” ± 5/64” waste tees.

ELECTRICAL CONNECTION

110-120 VAC power outlet, 9 Amps Minimum.

LENGTH OF SERVICES (FROM PRODUCT EXIT POINT)

Drain hose - 889/16” (2250mm) Inlet hose - 687/8” (1750mm) Power supply cord - 44” (1125mm)

NOTE: Services approximately exit product 77/16” (189mm) from left; 215/8” (550mm) from front; 311/4” (793mm) from top.

R

w

 

* w

NN

 

 

 

NN

w

#

**

w

NN

NN

 

 

 

5BC

 

 

 

 

4JEF 7JFX

 

 

 

 

w

 

 

NN

 

 

%SBXFS 0QFO

Prefinished model shown

* For an Integrated DishDrawer® the product depth is specified with an

11/16” (18mm) Integrated Panel thickness.

w

NN

NN

 

w

 

 

 

 

 

 

 

w

 

 

 

 

 

 

 

w w

NN

**Depth of product excludes Curvature (13/16” (30mm) Prefinished only,) or Handle.

TOE KICK DEPTH

Prefinished & Flat Door 2”-43/8 (50-110mm);

Integrated 5” (127mm) less the Toe Kick Panel thickness. Minimum Panel thickness using the supplied screws is 3/8” (9mm).

# DOOR FRONT HEIGHT

Prefinished & Flat Door 305/64” (764mm);

Integrated 281/4” (717.5mm) minimum.

THE CAVITY

w

NN

NN

4DSFX w NN

w

 

 

 

 

GSPN GSPOU PG DBCJOFUSZ

NN

 

 

 

 

 

 

 

 

 

 

 

w

+

 

×

.JO UIJDLOFTT PG DBWJUZ TJEFT JT w NN

 

 

 

w

 

 

 

 

 

 

 

 

 

 

 

 

 

N

NN

 

 

 

 

N

 

 

w

 

 

 

 

 

+

 

.PJTUVSF

NNw

1SPUFDUJPO

5BQF

 

 

 

 

 

 

 

 

 

w NN TFSWJDFT IPMF JNNFEJBUFMZ BEKBDFOU UP DPSOFS DBO CF FJUIFS TJEF

w NN

w NN UISPVHIPVU DBWJUZ

w NN

V Õ ÌiÀÌ «

ÃÌÕÀi «À ÌiVÌ

Ì>«i

w NN

These marks indicate mounting tab screw locations (refer to step 1 page 7)

NOTE: All depth measurements are taken from the front face of the adjacent cabinetry.

WARNING!

Be sure the edges of the services hole are smooth or covered. If the services hole is through a metal partition the hole must be protected with the Edge Protector provided to prevent damage to the power cord or hoses.

3

Fisher & Paykel DS603, DS6031, DD603, DD6031 User Manual

DOUBLE MODELS

PLUMBING OPTIONS

 

882.5mm)-

 

4

 

/

 

3

 

”-34

 

2

(750mm

 

/

 

1

 

29

v

 

 

 

 

 

 

 

 

 

 

 

vv MM

 

 

MM

 

 

 

 

 

 

 

R

OPTION 1

DishDrawer® and Standpipe Ø11/2” (38mm) with Air Gap.

OPTION 2

DishDrawer® with Waste Disposal.

OPTION 3

DishDrawer® using Air Break with Drain Hose Joiner.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(950mm)

top of AIR BREAK

wall-mounted)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 to or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heightMAX

(countertop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Prefinished Model is shown. There is no variation in plumbing between models. Option 1 is the preferred option. Drains will need to be separated to satisfy Kosher requirements. We suggest you confirm acceptability with your local Rabbi in respect to Kosher installations.