The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.

1 SAFETY AND WARNINGS

WARNING!

Electrical shock hazard

Disconnect product from main power supply before installing appliance.

Failure to do so may result in electrical shock or death

WARNING!

Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

WARNING!

Tipping hazard

Do not operate this apppliance until it has been securely anchored inside the cabinetry. The cabinet must be securely anchored to the floor.

Failure to use caution could result in injury or cuts.

Important safety precautions!

The CoolDrawer MUST be installed to allow for future removal from the enclosure if service is required. Do not seal the CoolDrawer into the cabinetry with silicone or glue. Doing so will make future servicing difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-inproduct, nor for repairing any damage that may be incurred by doing this.

Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord.

Failure to install the CoolDrawer correctly will invalidate any warranty or liability claims.

If the power supply cord is damaged, it must be replaced. Parts are available from your Authorised Fisher & Paykel dealer.

Cabinetry must be sufficiently robust to support a combined product and food load of 220 lb (100 kg). Bearers may be required to support the internal shelf.

Before you install the CoolDrawer, please make sure that

The switched power outlet must be outside the refrigerator drawer cavity so that it is accessible after installation.

The switched power outlet must be located outside the cavity, within 55” (1400 mm) from the CoolDrawer cavity if situated on the left-handside of the cavity and within 33” (840 mm) if situated on theright-handside of the cavity.

The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit through.

Installation of the CoolDrawer requires competent mechanical and electrical skills. Be sure to leave these Instructions with the Customer.

Installation must comply with your local building and electricity regulations.

At the completion of the CoolDrawer installation, the Installer must perform the Final Check List. Remove all packaging materials supplied with the CoolDrawer.

The CoolDrawer is manufactured for indoor use only.

2 PRODUCT DIMENSIONS

Installation diagrams for illustration purposes only

 

 

 

C

B

 

 

 

 

 

D

 

 

 

 

A

 

 

Product dimensions (inches [mm])

 

 

CoolDrawer

 

RB90S

RB36S

A

overall height of product (inc. installation brackets)

25 / ” (640)

B

overall width of product

33 / ” (855)

C

overall depth of product (excl. drawer panel; inc. power cord)

21 / ” (557)

D

depth of drawer (open) (excl. handle)

20 ½” (520)

 

 

 

3 CABINETRY DIMENSIONS

Installation diagrams for illustration purposes only

An internal shelf can be used as an alternative to spacer blocks to position the product at the correct height. In this case additional cutouts will be required. Refer to Step 7.

A

B

 

E

C

H

 

 

F

D

G

 

 

G

 

F

Cabinetry dimensions (inches [mm])

CoolDrawer RB36S RB90S

 

 

 

 

A

overall width of cabinetry frame

36” (914)

B

minimum inside width of cabinetry frame

34” (864)

C

height from frame inner face to top of spacer block

25 / ” (644)

D

height below top of spacer block to frame inner*

max. 4 / ” (120)

(to allow for outlet duct height)

min. / ” (21)

 

E

minimum height of toe kick

3” (75)

F

minimum depth** of toe kick

1 / ” (40)

G

minimum distance from front of cabinetry to rear wall

22 / ” (560)

H

width of spacer blocks

1 / ” (50)

*Minimum internal height of cabinetry frame can be 25 / ”(644mm) if outlet duct is not used.

**All depth measurements are taken from the front face of the cabinetry frame (not drawer panel)

Minimum clearances (inches [mm])

/ ” (2 mm)

½” (13 mm)

4 PARTS SUPPLIED

Installation brackets (left-handand righthand side) (2)

Phillips 16 mm

Trim brackets (4)

Pan Head

Installation

Power

Outlet duct (1)

Pan Head

( / ” ) wood

 

16 mm ( / ” )

trims (2)

cord (1)

 

16 mm ( / ” )

screw (6)

 

screw (12)

 

 

 

screw (2)

Drawer Panel

Phillips

attachment

16 mm

hooks (3)

( / ” ) wood

 

screws (6)

5 CAVITY PREPARATION

Important!

Disconnect power to surrounding appliances before preparing cavity.

Recommended to allow the vertical removal of the refrigerator bins.

Benchtop

max.

Panel

 

¾” (20 mm)

 

min. ø 1 / ” (50 mm)

min. 21”

(535

mm)

 

min. 5” (130 mm)

min. 21” (535 mm)

min. 5” (130 mm)

Shows cutout if cabinetry depth at 21 / ” (550 mm)

Note: Services

can be located

.

 

 

either side

of CoolDrawer

 

 

max. 33” (840 mm)

6 PANEL PREPARATION

 

A

 

 

 

 

 

 

 

Installation diagrams for illustration purposes only

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

D height of

Drawer

 

 

 

 

 

 

 

Drawer Panel

 

 

 

 

 

 

 

 

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/ ” (4 mm)

 

 

 

 

 

 

 

 

 

 

False

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

width of Panels

 

 

height of False

 

 

 

 

Panel

 

 

 

 

-20mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

/

 

 

 

 

 

 

 

 

 

 

 

 

 

SIDE VIEW

 

 

 

 

 

 

 

 

 

Benchtop

 

 

 

A

 

 

 

 

 

 

 

 

 

 

panel

 

 

 

 

 

 

 

 

D

Drawer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

C

panel

 

 

 

 

 

 

 

 

 

False

 

 

 

 

 

Integrated Panel material

/ - /” (16 - 20 mm) panel thickness (¾” [18 mm] recommended). Maximum weight of 15.5 lb (7 kg).

Adequately sealed to withstand moisture (122OF/50OC @ 80% RH)

Height of Drawer Panel

The following information is required to correctly define your drawer panel height:

Dimension

AReveal dimension

BHeight between top of spacer block and underside of benchtop

CBottom face of Drawer panel to top of spacer block

DDrawer panel height

To calculate D complete the following equation:

D = B - A - C

i.e. For the F&P prefinished panel with a ¼“ (6 mm) reveal:

18 ¾” (476 mm) = 26 ¼” (666 mm) - ¼” (6 mm) - 7 ¼” (184 mm)

Data Source

Your kitchen designer Your kitchen designer

Your kitchen designer (Min. 6” [152 mm]) (Max. 7 ¼” [184 mm]) Calculated from A, B & C

Height of the False Panel

Determine the height of the false panel according to your individual kitchen cabinetry requirements maintaining a /” (4 mm) gap between panels.

F&P prefinish panel width is 35 ¼” (896 mm)

F&P prefinish panel height (D) is 18 ¾” (476 mm)

7 CREATE CUTOUTS IN FRAME

If the cabinetry does not already have cutouts, ensure the modifications below are made.

max. / ” (16 mm)

1 / ” (50 mm)*

4” (102 mm)

 

30 / ” (764 mm)**

(40 mm)

1 /

8 ½” (215 mm)

11” (280 mm)

8 ½” (215 mm)

3” (76.5 mm)*

*Cutout dimensions referenced from inside face of cabinetry frame.**Only with cabinetry with internal shelf

9 ATTACH OUTLET VENT DUCT

1

2

Important!

Cut outlet duct to be flush with top of spacer block.

3

4

8 LOCATE & SECURE INSTALL BRACKETS

3

 

 

3

Important!

3

 

Ensure a minimum of 3 screws

 

2

per side are used. The rear screws

2

must always be used. Horizontal

 

fixing is also optional.

 

 

(25

mm)

1”

 

 

 

min. 33 / ” (860 mm) max. 33 / ”(862 mm)

1

10 ATTACH POWER CORD & TRIM BRACKETS

Important!

Ensure the power cord is clipped in place.

Important!

1

Note correct orientation of bracket.

2

11 MOVE PRODUCT INTO CAVITY

1 / ”

(46 mm)

3

2

Important!

Be careful not to damage power supply cord when pushing product into cavity.

Important!

Do not screw in trim brackets at this stage.

1

1

2

12 FIT DRAWER PANEL ATTACHMENT HOOKS

1

 

(35 ½” [902 mm])

12 ¼” (311 mm)

12 ¼“ (311 mm)

 

 

/

 

16

mm) (414

9 mm X

2

x 3

/ ” (5 mm)

 

/ ”

X = 7 / ” (194mm) - C,

 

 

 

 

 

(18 mm)

 

 

 

 

 

where C is bottom face

 

 

 

 

 

 

 

 

 

 

 

 

of panel to top of spacer

 

 

 

 

/

 

block, see

6

 

 

 

 

 

 

 

/

-

 

 

 

 

 

mm)

/ “

 

 

(16

- 20

 

 

 

(2.5 mm)

 

 

 

 

 

 

 

Attach handle as necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ensure all screws are flush

/ ” (1 mm)

 

 

 

 

 

 

with panel surface.

 

 

 

 

 

13 ATTACH DRAWER PANEL TO FRONT OF DRAWER

1 2345

Close the drawer and check vertical clearances

Hook drawer panel onto drawer front channel

6

Replace panel on

drawer and confirm

vertical clearances

Remove the panel and adjust the TOP attachment hooks

as necesary

7 8

Open drawer and

Close the drawer and ensure it is flush

Ensure there is clearance

clamp panel onto

drawer by tightening

with adjacent cabinetry. If not, the

between panel and cabinetry

the BOTTOM

product may have to be pulled back

when drawer is fully closed

attachment hook

or forward.

 

Slide panel to achieve even horizontal clearances

14 SECURE PRODUCT TO CABINETRY

15 ATTACH TRIMS TO SIDES OF CABINETRY

&

 

Open drawer and secure product to cabinetry using four Trim brackets and screws.

 

'

16 ATTACH FALSE PANEL

17 CHECK OPERATION

(

Attach the false panel securely as recommended by the cabinet maker.

/ ” (4 mm)

/ ” (2 mm)

&

Important!

The false panel needs to be removable for

 

servicing.

Important!

Ensure you check basic operation and perform the final checklist.

18 FINAL CHECKLIST

TO BE COMPLETED BY THE INSTALLER

Has all packaging been removed from the appliance?

Is the appliance securely fastened to the cabinetry?

Does the drawer slide freely and close properly?

Has the outlet duct been installed correctly?

Is the appliance level?

Are the panels securely attached?

Have the panels been properly aligned for correct operation and appearance? Are all clearances even?

Is there clearance between drawer and cabinetry frame?

Has the power cord been plugged into a properly grounded 3-prongoutlet, which has been installed in accordance with all applicable electrical codes?

OPERATION:

Is the control panel lit?

Can you hear the compressor motor running?

When a hand is placed near the toe kick, can airflow be felt under front right-handside of appliance?

Have you demonstrated the basic operation to the customer?

Installer’s name:

Installer’s signature:

Installation company:

Date of installation:

LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER

www.fisherpaykel.com 840509B FRAMED CABINETRY 08.08