Extech MA200 Operating Manual

4 (1)
Extech MA200 Operating Manual

User’s Guide

400A AC Clamp Meter

Model MA200

Introduction

Thank you for selecting the Extech MA200 AC Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Diode Test, and Continuity. This professional meter, with proper care, will provide years of safe reliable service.

Safety

International Safety Symbols

This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present

Double insulation

A UL mark does not indicate that this product has been evaluated for the accuracy of its readings.

SAFETY NOTES

Do not exceed the maximum allowable input range of any function

Do not apply voltage to meter when resistance function is selected.

Set the function switch OFF when the meter is not in use.

Remove the battery if meter is to be stored for longer than 60 days.

WARNINGS

Set function switch to the appropriate position before measuring.

When measuring volts do not switch to current/resistance modes.

Do not measure current on a circuit whose voltage exceeds 240V.

When changing ranges using the selector switch always disconnect the test leads from the circuit under test.

Do not exceed the maximum rated input limits.

OVERVOLTAGE CATEGORY III

This meter meets the IEC 610-1-95 standard for OVERVOLTAGE CATEGORY III. Cat III meters are protected against overvoltage transients in fixed installation at the distribution level. Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation.

2

MA200 Version 1.4 06/06

Specifications

Function

 

Range

Accuracy (of reading)

 

 

 

 

AC Current

 

2.000 ACA

± (2.5% + 10 digits)

 

 

 

 

 

 

20.00 ACA

± (2.5% + 4 digits)

 

 

200.0 ACA

± (2.5% + 4 digits)

 

 

400 ACA

± (3.0% + 5 digits)

AC Voltage

 

200.0mV,

± (1.5% + 30 digits)

 

 

2.000V

± (1.5% + 3 digits)

 

 

20.00V

 

 

200.0V

 

 

 

600V

± (2.0% + 4 digits)

DC Voltage

 

200.0mV

± (0.5% + 5 digits)

 

 

2.000V

± (1.2% + 3 digits)

 

 

20.00V

 

 

200.0V

 

 

 

600V

± (1.5% + 3 digits)

Resistance Ω

 

200.0

± (1.0% + 4 digits)

 

 

2.000k

± (1.5% + 2 digits)

 

 

20.00k

 

 

200.0k

 

 

 

2.000M

± (2.0% + 3 digits)

 

 

20.00M

± (3.0% + 5 digits)

Jaw size

0.9" (23mm) approx.

 

Display

3-1/2 digits (2000 counts) LCD

 

Continuity

Audible tone < 120Ω approx.

 

Diode Test

Open circuit voltage < 1.5VDC;

 

 

Test current 0.3mA (typical)

 

AC V bandwidth

50Hz to 400Hz

 

AC A bandwidth

50/60Hz

 

Low battery indication

“BAT” is displayed

 

Overrange indication

“OL” is displayed

 

Auto Power OFF

After 15 minutes

 

Measurement rate

2 per second, nominal

 

Input Impedance

7.8MΩ (V DC and V AC)

 

Operating Temperature

41ºF to 104ºF (5ºC to 40ºC)

 

Storage Temperature

-4oF to 140oF (-20oC to 60oC)

 

Operating Humidity

Max 80% up to 87ºF (31ºC) decreasing linearly to 50% at

 

104ºF(40ºC)

 

Storage Humidity

<80%

 

Operating Altitude

6560ft. (2000meters)

 

Batteries

(2) 1.5V AAA batteries

 

Weight

0.44lb (200g)

 

Size

7.87” x 1.97” x 1.38” (200x50x35mm)

Safety

For indoor use and in accordance with the requirements for

 

double insulation to IEC1010-1 (1995): EN61010-1 (1995)

 

Overvoltage Category III, Pollution Degree 2.

 

3

MA200 Version 1.4 06/06