Euro-Pro EP035H3 User Manual

Turbo Hand Vac with
TAPCLEAN®HEPA Dust Cup Filter
OWNER’S MANUAL
Models EP035H3 120V., 60Hz., 6.67 Amps
For information or assistance:
94 Main Mill Street, Door 16 Plattsburgh, NY 12901
Model EP035H3
ONE (1) YEAR LIMITED WARRANTY
EURO-PRO Operating LLC warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date of the original purchase, when utilized for normal household use, subject to the following conditions, exclusions and exceptions.
If your appliance fails to operate properly while in use under normal household conditions within the warranty period, return the complete appliance and accessories, freight prepaid to EURO-PRO Operating LLC, 94 Main Mill Street, Door 16, Plattsburgh, NY 12901. If the appliance is found to be defective in material or workmanship, EURO-PRO Operating LLC will repair or replace it free of charge. Proof of purchase date and $9.95 to cover the cost of return shipping and handling must be included. *
Non-durable parts including, without limitation, dust cup filters, brushes and electrical parts which normally require replacement are specifically excluded from warranty.
The liability of EURO-PRO Operating LLC is limited solely to the cost of the repair or replacement of the unit at our option. This warranty does not cover normal wear of parts and does not apply to any unit that has been tampered with or used for commercial purposes. This limited warranty does not cover damage caused by misuse, abuse, negligent handling or damage due to faulty packaging or mishandling in transit. This warranty does not cover damage or defects caused by or resulting from damages from shipping or repairs, service or alterations to the product or any of its parts, which have been performed by a repair person not authorized by EURO-PRO Operating LLC.
This warranty is extended to the original purchaser of the unit and excludes all other legal and/or conventional warranties. The responsibility of EURO-PRO Operating LLC if any, is limited to the specific obligations expressly assumed by it under the terms of the limited warranty. In no event is EURO-PRO Operating LLC liable for incidental or consequential damages of any nature whatsoever. Some states do not permit the exclusion or limitation of incidental or consequential damages, so the above may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
*Important: Carefully pack item to avoid damage in shipping. Be sure to include proof of purchase date and to attach tag to item before packing with your name, complete address and phone number with a note giving purchase information, model number and what you believe is the problem with item. We recommend you insure the package (as damage in shipping is not covered by your warranty). Mark the
outside of your package
improve our products, therefore the specifications contained herein are subject to change without notice.
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
Please fill out and mail the product registration card within ten (10) days of purchase. The registration will enable us to contact you in the unlikely event of a product safety notification. By returning this card you acknowledge to have read and understood the instructions for use, and warnings set forth in the accompanying instructions.
RETURN TO EURO-PRO Operating LLC, 94 Main Mill Street, Door 16, Plattsburgh, NY 12901
_________________________________________________________________________________________
Model EP035H3
Appliance model
________________________________________________________________________________________ Date purchased Name of store
_________________________________________________________________________________________ Owner’s name
________________________________________________________________________________________ Address City State Zip code
Printed in China
“ATTENTION CUSTOMER SERVICE”. We are constantly striving to
OWNERSHIP REGISTRATION CARD
8
IMPORTANT SAFETY INSTRUCTIONS
When using your TURBO HAND VAC, basic safety precautions should always be observed, including the following:
1. Read all instructions before using your hand vacuum.
2. Use the system only for its intended use.
3. To protect against a risk of electric shock,
do not immerse any part of the system in water or other liquids.
4. Never yank cord to disconnect from
outlet; instead, grasp plug and pull to disconnect.
5. Do not allow cord to touch hot surfaces.
6. Do not pull cord around sharp corners or
close door on cord.
7. Do not operate the system with a damaged
cord or plug, or if the appliance or any other part of the system has been dropped or damaged. To avoid the risk of electric shock, do not disassemble or attempt to repair the hand vacuum . Return the system to EURO-PRO Operating LLC (see warranty) for examination and repair. Incorrect re-assembly or repair can cause a risk of electrical shock or injury to persons when the is used.
8. Close supervision is necessary for any
appliance being used by or near children. Do not leave the system unattended while connected.
9. Keep hair, loose clothing, fingers and all
parts of body away from opening and moving parts.
10. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
11. Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.
12. Use extra care when cleaning on stairs.
13. Do not use the hand vacuum without the HEPA dust cup filter in place.
14. This appliance is intended only for household use. Follow all user instructions in this manual.
To reduce the risk of fire, electric shock, or injury:
Do not leave the plugged in when unattended. Unplug the electrical cord when not in use and before servicing.
Do not allow to be used as a toy. Close attention is necessary when used by or near children, pets or plants.
Use only as described in this manual. Use only manufacturer’s recommended accessories.
Do not pull cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Keep cord away from heated surfaces.
•Use only extension cords UL-rated or cUL at 15 amperes. Extension cords rated for less amperage may overheat. Care should be taken to arrange the cord so that the cord cannot be pulled or tripped over.
Turn off all controls as applicable before unplugging from electrical outlet.
Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Do not handle plug or hand vacuum with wet hands or operate without shoes.
Do not put any objects into openings. Do not use with any opening blocked. Keep free of dust, lint, hair and anything else that may reduce air flow.
Store your appliance indoors in a cool, dry area.
Keep your work area well lit.
Do not immerse the hand vacuum into water or other liquids.
Keep end of hose and other openings away from your face and body.
Use only on dry surfaces.
Using improper voltage may result in damage to the motor and possible injury to the user. Correct voltage is listed on rating label.
SAVE THESE INSTRUCTIONS
For Household Use Only
WARNING: To reduce the risk of electric shock, this appliance has a
polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not modify the plug in any way.
1
Rev. 05/04
GETTING TO KNOW YOUR HAND VACUUM
TROUBLE SHOOTING GUIDE
PROBLEM POSSIBLE REASON POSSIBLE SOLUTION
HEPA FilterDebris Screen
12
HAND VACUUM WILL NOT OPERATE
HAND VACUUM WILL NOT PICK-UP OR SUCTION POWER IS WEAK
TURBO BRUSH DOES NOT ROTATE OR ROTATES SLOWLY
DUST ESCAPING FROM HAND VACUUM
HAND VACUUM HOSE OR BRUSHES WILL NOT PICK-UP
1. Power cord not firmly plugged into outlet.
2. No power in wall outlet.
3. Needs servicing.
4. Thermostat has tripped.
1. Dust cup is full.
2. Unit clogged.
3. HEPA Dust Cup Filter needs cleaning or replacing.
1. Rotating brush or elbow obstructed.
2. Hose obstructed.
3. HEPA dust cup filter clogged.
1. Dust cup is full.
2. HEPA Dust Cup Filter is not installed correctly.
3. There is a puncture/hole in HEPA Dust Cup Filter.
1. Hose clogged.
2. Dust cup is full.
1. Plug unit in firmly.
2. Check fuse or breaker. Replace fuse/reset breaker.
3. Call 1-800-798-7398.
4. Turn the unit off and unplug from outlet. Allow to cool.
1. Empty dust cup – (see pages 5/6).
2. Turn unit off and unplug from wall outlet. Remove HEPA Dust Cup Filter and check for object(s) in air duct and remove.
3. Clean or replace HEPA Dust Cup Filter.
(see pages 5/6)
1. Clear obstructions. (see page 5.)
2. Clear obstruction.
3. Clean HEPA dust cup filter. (See pages 5/6.)
1. Empty dust cup.
2. Review HEPA Dust Cup Filter instructions.
(see pages 5/6)
3. Replace HEPA dust cup filter. (see pages 5/6)
1. Remove hose and/or bushes. Remove obstruction from hose.
2. Empty and clean dust cup.
5
11
1. Dust Cup Release Button
2. On/Off Power Switch
3. Handle
4. Intelli-Sense Filter Monitor
TM
5. Dust Cup (Container)
6. Suction Hole
Technical Specifications
Voltage: 120V., 60Hz. Power: 6.67 A., 800 Watts
7. Shoulder Strap
11
8. Pet Hair Removal Attachment
9. Cleaning Brush
10. Flexible Hose
11. Hepa Filter Assembly
12. Air Driven Turbo Brush
2
ORDERING REPLACEMENT DUST CUP FILTERS
TO ORDER REPLACEMENT FILTERS OR FOR TECHNICAL
SUPPORT
for Model EP035H3
Call: 1-800-798-7398
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
Please Note: After each Use - Always remove the Filter Debris Screen from the HEPA Dust Cup Filter, then vigorously “TapClean” HEPA Filter until no more dust can be removed. Filter should be rinsed and completely dried at least once a month or when suction appears reduced. To wash your HEPA Dust Cup Filter, hold filter cartridge by frame flange and rinse under a tap until all observable dirt has been removed. Some discoloration of the HEPA filter material may occur, this is normal and will not affect the filter's performance. When finished, shake off excess water. Do NOT wash in dishwasher. It is important that when you wash the HEPA dust cup filter, you allow it to dry
COMPLETELY before using again. We recommend 24 hours to air dry. DO NOT DRY IN DRYER.
7
OPERATING INSTRUCTIONS cont.
PRECAUTIONARY MEASURES
Cleaning & Changing the HEPA Dust Cup Filter (cont.)
3. Empty the dust from the Dust Cup (container).
4. Separate the debris screen from the HEPA filter cartridge by grasping the debris screen with one hand and the filter frame with the other and pull apart. (fig. 4)
Debris
Screen
Fig. 4
5. Vigorously “TapClean” the HEPA Dust Cup Filter on a hard surface until no more dust is observed falling out from between the pleats of the filter. (fig. 4)
6. “TapClean” the Debris Screen or rinse under a faucet until clean. (fig. 5) Remember that the Debris Screen must be completely dry before reinstalling in the vacuum.
7. Replace the Debris Screen on the HEPA Dust Cup Filter and reinstall filter assembly in the vacuum. (not shown)
Fig. 4
HEPA Filter
Fig. 5
Debris
Screen
PLEASE NOTE
: The white pleated filter material in the HEPA Dust Cup Filter will discolor over time -This is NORMAL and will NOT affect the performance of the filter. If the HEPA Dust Cup Filter is properly "TapCleaned” after each use and suction does not return to 100%, then we suggest that the HEPA filter be “TapCleaned”
Warning: Allow 24
hours for drying before replacing in unit.
Fig. A
Wash once a month or when suction appears reduced.
vigorously until no more dust can be removed, then rinsed under the faucet and allowed to dry for 24 hours before refitting into the vacuum. (Fig. A) Wash once a month or when suction appears reduced.
CAUTION: The suction hole must be
open, free of any obstructions at all times. Otherwise, the motor will overheat and could become damaged.
Motor Thermostat
Important: This unit is equipped with
a motor protective thermostat. If for some reason the vacuum cleaner should overheat, the thermostat will automatically turn the unit off. Should this occur:
• Push the On/Off button once.
• Disconnect the plug from the power source.
• Check the source of overheating problem. (i.e. clogged hose or filter)
• If clogged hose or filter is found, unclog the hose and replace the filters.
• Wait at least 45 minutes before attempting to reuse the vacuum.
• After unit has cooled down for 45 minutes, plug in the cleaner and push the On/Off button. The vacuum should start again.
• If the vacuum still does not start, contact customer service at 1-800-798-7398.
Important: If the suction opening in the unit or the hose become blocked, switch off
the vacuum cleaner and remove the blocking substance before you start the unit again.
1. Do not operate the vacuum cleaner to close too heaters, or radiators.
2. Before inserting the power plug into the wall outlet, make sure that your hands are dry.
3. Do not vacuum any liquids.
4. Keep hair, loose clothing, fingers, feet and all parts of body away from openings.
5. When pulling out the power plug from the wall outlet, pull the plug not the power cord.
6. Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.
7. Do not use without HEPA dust cup filter in place.
8. Before you start vacuuming, make sure to remove large or sharp objects that might damage the vacuum.
6
3
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS
Warning: Always unplug from
electrical outlet before opening the dust cup (container).
Note: HEPA dust cup filter must be
used when operating the hand vacuum.
Using The Unit As A Hand Vacuum
1. To open the dust cup (container), push button and pull out the dust cup. Verify that the HEPA dust cup filter is inside, then attach the dust cup (container) to the hand vacuum.
2. To use the Hand Vacuum with the shoulder strap, attach it to the unit as shown below.
3. To attach the oval brush, air driven turbo brush or the pet hair removal attachment to the Hand Vacuum, push attachment into the suction hole, as shown below.
NOTE: The pet hair removal
attachment is for use on upholstery, drapes and other fabric surfaces to remove lint, pet hair, etc. THE PET HAIR REMOVAL
ATTACHMENT IS NOT INTENDED TO BE USED AS A PET GROOMING DEVICE.
4. To use the flexible hose, push the end of the hose into the suction hole, then attach the desired brush to the other end of the flexible hose, as shown below.
How To Operate Your Hand Vacuum
1. Hold the hand vacuum firmly in
your hand by the Handle.
2. Push the On/Off Power Switch to
“On” position.
3. Start vacuuming.
CAUTION: The Hand Vacuum is
a very powerful unit. Make sure that you hold it firmly, otherwise it can slip out of your hand and cause injury.
NOTE: When the Intelli-Sense
Filter Monitor that the dust cup is full or filter needs cleaning. You must empty the dust from the dust cup and clean the HEPA dust cup filter right away. (See illustration below.)
4
TM
lights up, it means
Using The Unit With Air Driven Turbo Brush
The efficiency of your air driven turbo brush depends on the bristle brush rotating at high speed. Strong air suction is needed to accomplish this. In order to ensure that maximum air suction is maintained, please read the following instructions:
1. Empty the dust cup frequently.
2. Always "TAPCLEAN" the HEPA dust cup filter when emptying the dust cup container.
3. Ensure that the rotating brush is kept free of hair and string which may accumulate and decrease brush performance.
4. Keep Air Driven Turbo Brush turbine free of dirt and foreign matter. (See illustration below for cleaning instructions.)
Cleaning Air Driven Turbo Brush
Locking
Latch
Fig. 1
From time to time, the turbine of your turbo brush will require cleaning. To do this:
1. Remove the turbo brush from the hose or unit.
2. Turn turbo brush over and open the hinged cover to access the turbine wheel. (see fig. 1)
3. There may be some dust, lint, hair, etc on the turbine wheel. Remove as much of this as possible.
4. You may also use the unit’s hose to remove any additional debris from the turbine.
Tilt
Upwards
Turbine
Wheel
5. Ensure that the turbine wheel moves freely by rotating it with your finger. If the turbine does not rotate, call
Customer Service for help.
6. Close and lock the hinged cover on the turbo brush and continue vacuuming.
Cleaning & Changing the HEPA Dust Cup Filter
Warning: Always unplug the unit from
electrical outlet before opening the Dust Cup (container).
Important: Do NOT use the HEPA filter
cartridge without the debris screen in place.
Warning: After each Use - Always
remove the Filter Debris Screen from the HEPA Dust Cup Filter, then vigorously “TapClean” HEPA Filter until no more dust can be removed.
IMPORTANT, Please Note : The “TapClean” HEPA Dust Cup Filter & Debris Screen will stop most of the tiniest dust particles from re-entering the air you breathe. In fact it stops 99.97% of all particles as small as 0.3 microns - many times smaller than a human hair!!! Because of this incredible filtration performance, the HEPA Dust Cup Filter will quickly accumulate, inside the white filter folds, many fine dust particles that are difficult to see but which will eventually block or reduce your suction power - if not cleaned properly. Clean the HEPA Filter and Debris Screen after each use as described in this section.
1. To open the Dust Cup (container), push button and detach the Dust Cup (container ). (Fig. 2)
2. Pull out the HEPA Dust Cup Filter. (Fig. 3)
Fig. 2
5
Fig.3
Loading...