Enerco 4000ID, 1000ID, 2000ID, 3000ID User Manual

0 (0)
mr. heater

Model

Operating Instructions and Owner’s Manual

 

 

READ INSTRUCTIONS CAREFULLY: Read

 

heatstar

 

 

and follow all instructions. Place instructions in

 

BY eNERCO

 

 

a safe place for future reference. Do not allow

 

 

 

1000ID,

2000ID

Model

1000ID,

2000ID

anyone who has not read these instructions to

3000ID

 

3000ID,

4000ID

 

assemble, light, adjust or operate the heater.

 

 

 

 

 

 

 

 

 

 

INDIRECT FIRED

PORTABLE HEATER

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

­— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

— Service must be performed by a qualified service agency.

This is a vented portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion air and ventilation must be provided. Refer to page 5.

ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001

08/08 #50120

WARNING:

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.

WARNING:

NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNING:

FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.

WARNING:

The State of California requires the following warning:

COMBUSTION BY-PRODUCTS PRODUCED WHEN US-

ING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).

WARNING:

READ THE INSTRUCTIONS GIVEN IN THIS MANUAL BEFORE USING THE APPLIANCE.

DO NOT USE GASOLINE, NAPHTHA OR VOLATILE

FUELS.

THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE

IS CONNECTED MUST COMPLY WITH ALL SAFETY REGULATIONS IN FORCE. A RESIDUAL CURRENT CIRCUIT BREAKER MUST BE PROVIDED ON THE MAIN DISTRIBUTION BOARD.

UNPLUG THE HEATER BEFORE ATTEMPTING ANY

SERVICE OR MAINTENANCE.

ALWAYS CHECK THE POWER SUPPLY CABLE BEFORE

USE. IT MUST NOT BE BENT, CRUSHED, OR ANYWAY DAMAGED.

THE POWER SUPPLY CABLE MUST BE REPLACED ONLY

BY QUALIFIED PERSONNEL.

ONLY USE AN ORIGINAL H07RN-F POWER CABLE

WITH WATERPROOF PLUG.

DO NOT TOUCH THE EXHAUST GAS OUTLET. DANGER

OF BURNS!

Contents

 

WARNINGS..................................................................................

2

SPECIFICATIONS...........................................................................

3

operation..................................................................................

4

Safety devices..........................................................................

4

MAINTENANCE............................................................................

5

ventilation...............................................................................

5

TROUBLESHOOTING.....................................................................

6

wiring diagrams.....................................................................

7

parts list..................................................................................

11

ENERCO GROUP, INC. |Indirect Fired Portable Heater

2

Operating Instructions and Owner’s Manual

Important

Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods or persons due to improper use of units.

General Recommendations

This indirect-fired heater runs on diesel fuel. Those with direct combustion send hot air and the combustion products into the room, while those with indirect combustion are fitted with a flue to take the fumes away through the chimney.

Always follow local ordinances and codes when using this heater:

Read and follow this owner’s manual before using the heater.

Use only in places free of flammable vapors or high dust content.

Never use heater in immediate proximity of flammable materials (the minimum distance must be 6 ft.).

Make sure fire fighting equipment is readily available.

Make sure sufficient fresh outside air is provided according

to the heater requirements. Direct combustion heaters should only be used in well vented areas in order to avoid carbon monoxide poisoning.

The heater is installed near a chimney to take away the fumes (see “Ventilation” on page 5) and connected to an electrical switchboard.

When the heater is connected to a flue pipe, the flue pipe shall terminate in a vertical section at least two feet long and sufficient draft shall be created to assure safe and proper operation of the heater.

Never block air inlet (rear) or air outlet (front).

In case of very low temperatures add kerosene to the heating oil.

Make sure heater is always under surveillance and keep children and animals away from it;

Before starting the heater always check free rotation of ventilator fan.

Indirect fired units only can be connected to air ducts to distribute warm air, with respect to the max. static pressure declared (see “TECHNICAL SPECIFICATION” sheet).

Unplug heater when not in use.

TECHNICAL SPECIFICATIONS

 

mh 1000id

mh 2000id

mh 3000id

 

 

hs 1000id

hs 2000id

hs 3000id

hs 4000id

 

 

 

 

 

 

 

 

 

 

 

 

Heat input

 

[kBTU/h]

110

205

300

400

 

 

 

 

 

 

 

 

Air flow

 

[cfm]

880

1,530

2,500

2,760

 

 

 

 

 

 

 

 

Fuel Type

 

 

 

Diesel/Kerosene/#1-2 Fuel Oil

 

 

 

 

 

 

 

 

 

Heat output

 

[kBTU/h]

91.9

174.9

254.4

335.6

 

 

 

 

 

 

 

 

Fuel consumption

 

[gal/h]

0.80

1.48

2.28

2.82

 

 

 

 

 

 

 

[lb/h]

5.53

10.35

15.07

20.07

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

 

1

1

1

1

 

 

 

 

 

 

 

 

Power supply

 

Voltage

[V]

120

120

120

120

 

 

 

 

 

 

 

 

 

 

Frequency

[Hz]

60

60

60

60

 

 

 

 

 

 

 

 

Electric consumption

[W]

520

785

1.240

1.440

 

 

 

 

 

[A]

5.76

8.30

11.40

13.20

 

 

 

 

 

 

 

 

 

 

Nozzle

 

[USgal/h]

0.60-80° S

1.00-45° W

1.20-45° W

1.50-45° W

 

 

 

 

 

 

 

 

Pump pressure

 

[psi]

167

P1: 137

P1: 160

P1: 203

 

 

 

 

 

P2: 239

P2: 350

P2: 348

 

 

 

 

 

 

 

 

 

 

 

 

Max static pressure

 

[in WC]

0.5

0.5

0.5

0.5

 

 

 

 

 

 

Recommended max. temp. in the air

[°F]

250

250

250

250

duct

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment of combustion air flap

[in]

a=0.32

-

-

-

 

 

 

 

 

-

A=1.02

A=1.50

B=1.14

 

 

 

 

 

 

 

 

 

 

Flue diameter

 

[in]

5.9

5.9

5.9

5.9

 

 

 

 

 

 

Compulsory flue draft

[in WC]

0.05

0.05

0.05

0.05

 

 

 

 

 

 

 

Tank capacity

 

[gal]

10.8

17.2

27.7

35.7

 

 

 

 

 

 

Dimensions, L x W x H

[in]

49.3x20.0x30.5

56.5x23.2x37.60

68.5x27.6x37.7

66.3x27.6x45.6

 

 

 

 

 

 

 

Net Weight

 

[lb]

94

176

264

330

 

 

 

 

 

 

 

 

ENERCO GROUP, INC. |Indirect Fired Portable Heater

3

Operating Instructions and Owner’s Manual

Operation

Before any attempt of starting the heater is made, check that your electrical supply conforms to the data on the model plate.

Control Board

1

3

4

2

5

O N

0

O N

1RESET BUTTON WITH CONTROL LAMP

2CONTROL LAMP

3MAIN SWITCH

4ROOM THERMOSTAT PLUG

5POWER CORD

Gap of Electrodes

X

Y

Z

Models

X

Y

Z

 

 

 

 

ID1000

.079 in

.118 in

.256 in

 

 

 

 

ID2000

.158 in

.098 in

.158 in

 

 

 

 

ID3000

.158 in

.098 in

.158 in

 

 

 

 

ID4000

.158 in

.098 in

.158 in

 

 

 

 

Clearances

The following minimum safety clearances from materials or objects in the surroundings of the heater must be ensured:

Sides

2.5 ft.

Air Inlet

2.5 ft.

Top

6 ft.

Air outlet

12 ft.

 

 

 

 

Floors and ceilings must be made of fireproof materials in the room where the heater is operated.

The air inlet and outlet must never be blocked for any reason.

Install the heater on a flat, level floor in a steady postion.

It is forbidden to connect direct-fired heaters to air ducts.

Warning

DO NOT USE GASOLINE, NAPHTHA OR VOLATILE FUELS.

STOP HEATER BEFORE ADDING FUELS.

ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME

DO NOT USE EXTERNAL FUEL SOURCE.

DO NOT OPERATE HEATER WHERE FLAMMABLE LIQUIDS

OR VAPORS MAY BE PRESENT.

DO NOT START HEATER WHEN CHAMBER IS HOT

DO NOT START HEATER WHEN EXCESS FUEL HAS ACCUMU-

LATED IN THE CHAMBER.

DO NOT PLACE COOKING UTENSILS ON TOP OF THE

HEATER.

PLUG ELECTRICAL CORD INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.

The heater can only work automatically when a control device, such as for example a thermostat or a timer, is connected to the heater. Connection to the heater is made by removing the socket cover(4) and inserting the thermostat plug.

To start the machine you must:

•If connected to the thermostat, turn the switch to (ON + ); •If not connected to the thermostat, turn the switch to (ON).

When unit is started for the first time or is started after the oil tank has been totally emptied, the flow of oil to the burner may be impaired by air in the circuit. In this case the control box will cut out the heater and it might be necessary to renew the starting procedure once or twice by depressing the reset button (1).

Should the heater not start, check that oil tank is full and depress reset button (1).

Should the heater still not work, please refer to chapter “OBSERVED FAULTS, CAUSES AND REMEDIES”.

Stopping the Heater

Set main switch (3) on “0” position or turn thermostat or other control device on lowest setting.

The flame goes out and the fan continues to work for approx. 90sec. cooling the combustion chamber.

Safety Devices

The unit is fitted with an electronic flame control box. In case of malfunction this box will cut in and stop the heater, at the same time the pilot lamp in the control box reset button (1) will light up.

Heaters are also equipped with an overheat thermostat safety cutout which will stop the heater in case of overheating. This thermostat will reset automatically but you will have to depress button (1) on control box before being able to restart the heater.

Transport

Warning

Before making any attempt to restart heater find and eliminate reason of overheating.

Before heater is moved it must be stopped and unplugged. Before moving the heater wait till it has totally cooled off and make sure oil tank cap is securely fixed.

ENERCO GROUP, INC. |Indirect Fired Portable Heater

4

Operating Instructions and Owner’s Manual

The hot air heaters with wheels must be wheeled. The suspended version which has no wheels must be transported with adequate machinery.

Maintenance

Preventive and regular maintenance will ensure a long trouble free life to your heater.

Warning

Never service heater while it is plugged in, operating or hot.

Severe burns or electrical shock can occur.

Every 50 hours of operation: disassemble filter and wash with clean oil, remove upper body parts and clean inside and ventilator with compressed air, check correct attachment of H.T. connectors to the electrodes and check H.T. cables, remove burner assembly, clean and check electrode settings, adjust according to scheme “GAP OF ELECTRODES”.

Flue Connections Diagram

Ventilation

6 “

Description

A)Minimal 39”

B)Minimal 39”

C)The shortest

D)The same or bigger than the smokes outlet diameter of heater

E)Minimal 1m

1)Anti-wind device provided with the heater

2)Horizontal crossing with minimal upside angle pitch of 5°

3)Chimney 8” x 8” of minimal inside measure

4)Chimney anti-explosion flap door

5)External seating wall

6)Chimney ending H shape

N.B. Above recommendation indicative only. Have your installation checked by local authority.

C

D

2

3

B

 

A

1

5

4

6

E

B

1

5

ENERCO GROUP, INC. |Indirect Fired Portable Heater

5

Operating Instructions and Owner’s Manual

Troubleshooting

TROUBLE

Cause

SOLUTION

Motor does not start, no ignition

No electrical current

Check mains (should be 120 V – 1~ – 60 Hz)

 

 

Check proper positioning and functioning of switch

 

 

Check fuse

 

Wrong setting of room ther-

Check correct setting of heater control. If thermostat, make

 

mostat or other control

sure selected temperature is higher than room temperature

 

Thermostat or other control

Replace control device

 

defective

 

 

Electrical motor defective

Replace electrical motor

 

Electrical motor bearings

Replace electrical motor bearings

 

defective

 

 

Burned out condenser

Replace condenser

 

 

 

Motor starts, no ignition or cuts out

Electric ignitor defective

Check connection of H.V. Ieads to electrodes and transformer

 

 

Check electrodes setting (see scheme “GAP OF ELECTRODES”)

 

 

Check electrodes for cleanliness

 

 

Replace H.V. transformer

 

Flame control box defective

Replace control box

 

Photocell defective

Clean or replace photocell

 

Not enough or no fuel at all

Check state of motor-pump plastic coupling

 

at burner

Check fuel line system including fuel filter for possible leaks

 

 

 

 

Clean or replace oil nozzle

 

Solenoid defective

Check electrical connection

 

 

Check thermostat LI

 

 

Clean or replace solenoid

 

 

 

Motor starts, heater emits smoke

Not enough combustion air

Make sure air inlet and outlet are free

 

 

Check setting of combustion air flap

 

 

Clean burner disc

 

Too much combustion air

Check setting of combustion air flap

 

Fuel contaminated or con-

Drain fuel in tank with clean fuel

 

tains water

Clean oil filter

 

 

 

Air leaks in fuel circuit

Check the seals on the ducts and the diesel filter

 

Not enough fuel at burner

Check pump pressure

 

 

Clean or replace fuel nozzle

 

Too much fuel at burner

Check pump pressure

 

 

Replace nozzle

 

 

 

Heater does not stop

Solenoid

Replace solenoid coil or complete solenoid

 

 

 

If heater still not working properly, please revert to nearest authorized dealer.

ENERCO GROUP, INC. |Indirect Fired Portable Heater

6

Operating Instructions and Owner’s Manual

Wiring Diagram

1000ID Series Models

Drawing Legend

FU

Fuse

RV

Control

IT

Transformer H.V.

TA

Room Thermostat

LI1

Overheat Thermostat

RE

Relays

EV1

Solenoid Valve 1°

AP

Control Box

FO

Photocell

PA

Air pressure control

CO

Condenser

RF

Heater filter

MV

Fan Motor

FA

Fan thermostat

ST

Electric pilot

PE

Ground

 

 

 

 

ENERCO GROUP, INC. |Indirect Fired Portable Heater

7

Operating Instructions and Owner’s Manual

Wiring Diagram

2000ID and 3000ID Series Models

Drawing Legend

FU

Fuse 20A

RV

Control

IT

Transformer H.V.

TA

Room Thermostat plug

LI1

Overheat Thermostat

RE

Relay

EV1

Solenoid Valve 1°

AP

Control Box

EV2

Solenoid Valve 2°

FA

Fan thermostat

FO

Photocell

PA

Air pressure control

CO

Condenser

RF

Heated filter

MV

Fan Motor

PA

Air pressure switch

ST

Electric pilot lamp

PE

Ground

 

 

 

 

ENERCO GROUP, INC. |Indirect Fired Portable Heater

8

Operating Instructions and Owner’s Manual

Wiring Diagram

4000ID Series Models

Drawing Legend

FU

Fuse 20A

TA

Room Thermostat plug

IT

Transformer H.V.

RE

Relay

LI1

Overheat Thermostat

AP

Control Box

EV1

Solenoid Valve 1°

FA

Fan thermostat

EV2

Solenoid Valve 2°

RF

Heated filter

FO

Photocell

CN

Connector

CO

Condenser

LI2

Overheat safety

MV

Fan Motor

 

thermostat

 

 

ST

Electric pilot lamp

PE

Ground

 

 

RV

Control

 

 

 

 

 

 

ENERCO GROUP, INC. |Indirect Fired Portable Heater

9

Operating Instructions and Owner’s Manual

Enerco 4000ID, 1000ID, 2000ID, 3000ID User Manual

 

 

 

 

 

 

02

 

05

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17 15

 

Optional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

84

 

 

 

 

 

 

 

 

04

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

 

 

42

 

 

 

87

88

 

 

 

78 77

 

 

 

 

 

 

 

 

 

 

 

 

86

 

 

 

 

 

 

 

 

 

 

 

 

41

 

 

 

 

 

 

 

 

 

 

 

Manual

 

 

 

 

 

 

 

 

A

 

 

 

89

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

08

 

 

 

 

 

 

 

Owner’s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

03

 

 

 

 

 

 

07

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

09

 

 

 

 

 

 

|IndirectFired Portable Heater 10 Operating Instructions and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

 

 

 

 

 

 

 

 

 

 

 

B

64

 

 

66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

36

 

 

18

 

 

 

 

20

 

 

 

 

 

65

 

 

 

 

 

 

83

 

 

 

 

 

 

 

62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

 

 

68

 

 

 

 

 

 

24

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

71

 

 

 

 

35

 

 

26

25

 

 

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

69

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35

49

48

47

46

 

 

34

 

 

 

 

 

A

 

 

 

 

 

 

50

81

 

 

 

 

 

 

 

 

74

 

 

 

 

45

 

 

 

 

 

 

 

 

 

 

 

51

 

 

 

44

 

33

 

 

 

27

 

 

 

 

 

 

68

 

 

 

 

 

29

 

 

 

 

 

 

 

 

HeaterPortableFiredIndirectSeries1000ID-

 

 

 

 

43

 

 

 

 

 

 

 

 

76

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

 

INC.

 

 

 

 

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

73

 

 

 

 

 

 

 

 

 

 

61

 

 

 

 

 

 

 

 

 

 

GROUP,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52

53 54 55

 

 

 

 

 

31

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77

ENERCO

 

 

 

 

 

 

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

59

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000ID Series Indirect-Fired Portable Heater Parts List

no.

Stock No.

Description

 

 

 

01

g06075-9010

Outlet cone

02

g06077

Chimney Ø 150

03

g06079

Combustion chamber support

04

g06081

Combustion chamber

05

g06083-9010

Upper body

06

g06085-9010

Lower body

07

e10677-110

Motor 200Wwith condenser

08

e11208

Condenser 20 µF

09

g06067

Motor flange

10

g06070-9010

Fan protection ring

11

t10207

Fan Ø300 18°

12

m20402

Elastic Plate U42-032

13

p30165

Inlet grille

14

i40330

Tube BP 1/4” FF L.420mm

15

i20104

Nipple FE 1/4” MM

16

t20239

Filter with cartridge

17

g06104-9005

Filter support

18

i40329

Tube BP 1/4”FF L.260mm

19

c30307

Protection cable Ø 35

20

p20174-9005

Handle

21

c30319

Plug Ø25

22

p20175-9005

Foot

23

i40331

Tube BP 1/4” F L.580mm

24

i30695

Pascante L.150mm

25

i30737

Nipple OT 1/4” M - M12x1.75M

26

g06068-9005

Power lead hook

27

g06099-9005

Fuel tank

28

c30356

Drain plug

29

g06105-9005

Wheel axle

30

g06106-9005

Wheels axle support

31

c10546

Wheel Ø 260 - Ø 25

32

m20202

Spring washer Ø20

33

i25019

Fuel tank

34

c30350

OR Ø30 x 2.62

35

g00212

El. Components drawer

36

c30425

Seal

37

p50127

Control box cover

38

g06108-9010

Base

39

e50101

Limit thermostat

40

g06087

Blast tube

41

e50102

Fan thermostat

42

g06072

Sleeve Ø8 x Ø6 x 9.5

43

p50126

Electr. Components drawer

44

e20508

Fuse holder

45

e10308

Fuse (6x30) 10A

No.

Stock no.

Description

46

g06102

Switch support

47

e50437

Pressure switches HONEYWELL

48

e20319

Terminal board

49

e20305

Terminal board

50

e11125

Relay finder 65.31 AC

51

e10917-2

Transformer H.T. 818C 110V

52

g06109

Transformer H.T. flange

53

g06103

Support

54

e40107

LANDIS LOA 21-24 base

55

e40113

Control box LANDIS LOA 21-24

56

g06073

Plate for electrical components

57

e10102-p

Switch 0 - 1

58

e20640

Thermostat plug 3P+T

59

e20665

Drain plug

60

e30443

El. wire with plug and cable

 

 

fastener

61

e11030

Lamp 230V

62

t20339

Nozzle 0.60 GPH 80° S

63

i33001

Nozzle support

64

p20526

Burner flange Ø 80mm

65

i31034

Nut M14

66

e10248

Electrode

67

g02076

H.T. Cable connect 90°

68

i40192

Micro pipe

69

e50306

Ld. ph. UnitL&G QRB1A

70

e50307

Fixing clamp

71

e50308

Photo resistance flange

72

c30352

Cable protection Ø15

73

t20429-1

Pump Danfoss BFP01

74

t20118

Solenoid spool BFP11-21 Danfoss

75

t20117

Solenoid valve Danfoss

76

i20115

Nipple FE 1/8” MM

77

e10513

Coupling K1

78

e20953

Cable holder PG11

79

e20954

Ring nut PG11

80

i20325

Connection1/8”

81

i31130

Conn. Straight Ø6 1/8”

82

i40332

Silicone pipe Ø5x9

83

c30319

Rubber tap

84

t20241

OR KIT oil filter

85

t20242

Filter cartridge

86

t20201

Oil filter 1/4”

87

t20234

OR KIT oil filter

88

t20206

Filter cartridge

89

t20212

Filter housing

ENERCO GROUP, INC. |Indirect Fired Portable Heater

11

Operating Instructions and Owner’s Manual

Loading...
+ 25 hidden pages