Empire Comfort Systems LS-30RS-1, LS-18RSS-1, LS-18RS-1, LS-24RSS-1, LS-24RS-1 User Manual

...
0 (0)
Empire Comfort Systems LS-30RS-1, LS-18RSS-1, LS-18RS-1, LS-24RSS-1, LS-24RS-1 User Manual

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

The White Mountain Log Collection

Installer: Leave this manual with the appliance.

Consumer:Retain this manual for future reference.

WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IFYOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

LOG SET FOR UNVENTED

GAS LOG HEATER

OR

VENTED DECORATIVE APPLIANCE

MODELS

LS-18RS-1/LS-18RSS-1

LS-24RS-1/LS-24RSS-1

LS-30RS-1/LS-30RSS-1

Sassafras/Sassafras Super Size

Log sets comply with ANSI Z21.11.2 Unvented Heaters and also comply with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State or local codes may only allowoperationoflogsetsinaventedconfiguration. Check your state or local codes.

WARNING: If not installed, operated and maintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.

Page 1

TABLE OF CONTENTS

 

Section

Page

Important Installation Guidelines....................................................................................................................

3

General Information ........................................................................................................................................

3

Sassafras Super Size Log Placement...............................................................................................................

4

Ember Placement LS-18RSS-1 Photos............................................................................................................

5

Ember Placement LS-24RSS-1 Photos............................................................................................................

6

Ember Placement LS-30RSS-1 Photos............................................................................................................

7

Sassafras Log Placement .................................................................................................................................

8

Ember Placement LS-18RS Photos.................................................................................................................

9

Ember Placement LS-24RS Photos...............................................................................................................

10

Ember Placement LS-30RS Photos...............................................................................................................

11

Parts Lists and Parts Views............................................................................................................................

12

How to Order Repair Parts ............................................................................................................................

12

Page 2

20171-3-0907

IMPORTANT INSTALLATION GUIDELINES

Proper Log Placement

Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner. The photos in this manual show the proper pinned position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs.

Logs must fit firmly onto the burner when positioned as shown in the photos. Malformed logs or logs with sloppy pin holes must be replaced.

Proper Placement of Rock Wool and Decorative Lava Rock

Rock wool can be added to burners for a glowing ember effect. It must be positioned only on the front portion of the burner. The photos in this manual show the proper placement of rock wool.

Decorative lava rock or small wood pieces should never be placed on the burner. These items are only for placement on the floor of the fireplace or firebox.

Proper Primary Airflow into Burner

For proper burner operation and flame appearance, the flow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. This flow of air is reduced if dirt, lint or other obstructionsbuild-uparoundorinsidetheventuri.Anyobstruction in the venturi tube area must be removed. The flow of air into the venturiisalsoreducedifthegasorificeisn’tcenteredintheventuri inletand/orisnotalignedwiththeventuri.Anymisalignmentofthe burner orifice may be corrected by bending the shutter cap holding the orifice to the inlet of the venturi tube.

Ceiling Fans, Portable Fans or Logs Installed Near Cold Air Returns

Ceiling fans or oscillating floor type fans need to be monitored during the operation of vent-free logs. If the air blows directly into the flame causing it to impinge on the log set, or firebox, it should be turned off or redirected. Ceiling fans could be reversed to possibly eliminate flame impingement, and the floor fan could be redirected. Upon installation, be aware of any cold air returns or vents in the proximity of the log set. Any draft created around

a vent-free log set can cause the flame to impinge on the log and create a sooting situation.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

Candles

Avoidtheuseofscentedordecorativecandleswhilethelogsetisin operation.Candlesproducearesidueintheairthatcreatesasootlike substance.Burningcandleswhilethelogsetisoperatingmagnifies the problem. It should be noted that candles, in general, produce soot.Theamountoftimeburnedandthequantityofcandlesburned will determine the amount of soot produced and deposited.

Make Owners Aware of Proper Log Set Operation

Properly installed and properly maintained log sets do not deposit soot on the logs. If users see soot appear on a log, call for service. Do not continue to operate the log set.

Sunken Fireplace

If installing this unit into a sunken fireplace, you must raise the floor to insure adequate airflow and guard against sooting. Raise fireplace floor using a non-combustible material, which is secure.

Glass Doors

Make sure that glass doors are open during all operations of the logset.Theopeningoftheglassdoorframeshouldbethedimension used for the minimum front opening of the firebox.

Wood Burning Fireplaces

The interior of the firebox and the chimney should be cleaned and free of all creosote before installing a gas burning log set. Creosote will soften when heated and can drop on the logset causing odors and possibly sooting.

WARNING:Beforeinstallinginasolid-fuelburningfireplace,the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

GENERAL INFORMATION

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency.The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for(a)theinstallation,testing,orreplacementofgaspipingor(b)the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/

NFPA54.*

*Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10018.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

In the State of Massachusetts, unvented propane and natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.

20171-3-0907

Page 3

SASSAFRAS SUPER SIZE LOG PLACEMENT

Before you begin: Do not, handle these logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs, wash your hands gently with soap and water.

All Logs

The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance.

Refer to Figure 1 for the following warning.

Warning: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

PROPER INSTALLATION SEQUENCE: LS-(18, 24, 30)RSS

(Figure 1)

1.Place left, rear (#1) log onto left, rear pin on rear log support.

2.Place right, rear (#2) log onto right, rear pin on rear log support.

3.Place left, front (#3) log onto two (2) left, front pins on burner pan.

4.Place right, front (#4) log onto two (2) right, front pins on burner pan.

5.Insert boss on left, top (#5) log into recess on left side of left, rear (#1) log and onto left side of left, front (#3) log.

6.Insert boss on center, top (#6) log into recess on right side of left, front (#3) log.

7.Insert round boss and square recess on (#7) right, top log into recess and boss on center, top (#6) log.

8.Compare the completed log installation with the appropriate photo from pages 5 through 7. Review previous steps to make any necessary adjustments.

9.Log placement is completed.

Attention: Do not use Figure 1 to order replacement logs. Refer to Page12PartsListandPartsViewtoorderlogsforyourappropriate model number.

Applyloosematerial(glowingembers)perappropriateInstallation Instructions and Owner's Manual. Replacement of loose material (glowing embers) must be purchased from Empire Comfort Systems, Inc. Application of excess loose material (glowing embers) may adversely affect performance of the heater.

WARNING:Allpreviouslyappliedloosematerialmustberemoved prior to reapplication.

Replacement Loose Material (glowing embers) Part Number

LS-18RSS

15999

LS-24RSS

15970

LS-30RSS

15970

Platinum Bright Embers

PE20-1

Note:AsinglelayerofembersistobeusedwhenapplyingPlatinum Bright Embers (alone or in combination with production embers) to the burner.

 

7

5

6

 

1

2

4

 

3

Log Placement

LS-(18, 24, 30)RSS Logs

Figure 1

The following WARNING applies when log set is installed onto an unvented gas burner assembly.

WARNING: This appliance is equipped for (natural or propane) gas. Field conversion is not permitted.

Page 4

20171-3-0907

Loading...