LIQUI-TECT® 410
Point Leak Detection Sensor
The Liqui-tect 410 (LT410) provides a single-point detection of leaks. The point detection sensor has two gold-plated sensing probes to prevent corrosion resistance and to provide accurate readings. The LT410 constantly monitors points for leaks,
internal faults and power failures and warns of any abnormal conditions. Mounting brackets allow for sensor height adjustment and leveling.
The LT410 is the ideal solution for sensing leaks under a raised computer floor or air conditioning drip pans. Two independent outputs provide added flexibility with the capacity to signal both a local alarm panel and a remote building management system or external equipment, such as motorized water shut-off valves.
The LT410 is also ideally suited for the following:
Applications |
|
Locations |
|
||
• Glycol, Chilled |
|
• Large-Scale Network Control |
Water Cooling |
|
Centers |
• Humidification |
|
• Data Centers |
Feed Water Piping |
|
• Server Rooms - Closets |
• Condensate Pumps |
|
• Unattended Remote Shelters |
and Drains |
|
• Mechanical Equipment Rooms |
• Unit and Ceiling |
|
|
|
• Sensitive Areas With |
|
Auxiliary Drip Pans |
|
|
|
Overhead Piping |
|
• Overhead Piping |
|
|
|
• Industrial Process Control |
|
Troughs |
|
|
|
Rooms |
|
|
|
To a Liebert |
|
|
environmental |
|
|
unit and |
|
|
an optional* |
|
|
monitoring |
|
|
panel |
|
|
To external |
|
|
power |
|
|
supply or |
|
|
directly |
|
|
from |
|
|
unit |
|
Leak detection |
|
|
|
|
|
zone (directly |
|
LT410 |
beneath unit) |
|
|
*Output connections to external alarm monitoring panels such as the Liebert contact closure alarm panels
Liqui-tect 410 Sensor
Power requirements |
24 VAC 100 mA, 50/60 Hz, 3 VA (max.) |
|
Dimensions |
6.35" x 2.25" x 4.46" |
|
W x D x H |
(161.2 mm x 57.2 mm x 113.2 mm) |
|
Weight (assembled) |
2.0 lbs (0.9 kg) |
|
Metal enclosure |
NEMA 1, IP 30 |
|
Environmental Conditions |
||
Operating temperature |
50°F to 104°F (10°C to 40°C) |
|
Operating humidity |
10% to 95% relative humidity |
|
(non-condensing) |
||
|
||
Operating altitude |
0 to 10,000 ft (0 to 3,048 m) |
|
Output Relays |
|
|
Contact rating |
2 Form-C; 3 A rating at 24 VAC |
|
Agency Listings |
|
|
UL |
UL916 |
|
C-UL |
C22.2, No. 205-M1983 |
|
CE |
Yes |
|
FCC Compliance |
47 CFR, Part 15 |
Dimensions-Top, Front & Side Views
TOP VIEW
5.85"
(148.5mm)
FRONT VIEW
4.46"
(113.2mm)
6.35"
(161.2mm)
SIDE VIEW
Form-C relay outputs & power wiring connection
2.25"
Adjustable (57.2mm) probe height
0.0–0.5"
(0.0–12.7mm)
Shipping weight: 2 Ibs (0.9 kg) Mounting holes: #8 screws
Red Wires |
Orange Wires |
|
Yellow Wires |
|
24 V, AC/DC |
Alarm Contact Rating |
Alarm Contact Rating |
||
@0.10A, 50-60Hz, DC |
24 VAC @ 3A |
|
24 VAC @ 3A |
|
Class 2 Circuit Only |
Class 2 Circuit Only |
|
Class 2 Circuit Only |
|
Power Power |
1-NO |
1-NC 1-COM 2-NO |
2-NC 2-COM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Gold-plated |
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
probes |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
Height adjustable |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
0-0.5" (0-12.7mm) |
||||
Ordering Information |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Product |
|
|
Quantity |
|
Description |
||||||||||
Number |
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LT410 |
|
|
|
|
|
Point Leak Detection Sensor |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Specification Sheet |
page 1 |