1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.The installation is to be in accordance with the National Electrical Code, “ANSI/NFPA 70-1999”and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8-footceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

NOTE: This fan is suitable for use withsolid-statespeed controls.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label.

You should record this data above and keep it in a safe place for future use.

2

U.L. Model No.: CF712

This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One 1/4” blade screwdriver

One wire stripper

Three wire connectors (supplied)

 

Three 60-Watt(max.) candelabra base bulbs

MATERIALS

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100ft.

12

!WARNING

Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor(2-wirewith ground) of the following size:

Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 6). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

For your convenience, check-offboxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Company. Substitution of parts or accessories not designated for use with this product by Emerson Electric Company could result in personal injury or property damage.

1.Check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

a.Fan motor assembly

b.Five fan blades

c.One ceiling cover with hanger bracket

d.Five blade flanges

e.One hanger ball/downrod assembly

f.Light fitter

g.Glass bowl

h.One loose parts bag containing:

1.Sixteen M5 x 6 washer head blade screws

2.One rubber gasket

3.Two wood pendants

4.Two couplings

5.Three wire connectors

6.One clevis pin

7.One hairpin clip

8.One Phillips round

head flange screw with lockwasher

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.

2.Remove the fan housing assembly from the protective plastic bag. Turn the upper styrofoam pad over and carefully place the fan motor assembly into the recess in the pad with the top of the motor facing up.

A

C

B

H

D

E

G

F

3

U.L. Model No.: CF712

IMPORTANT

Your ceiling fan is designed to be installed either in the standard manner, or in the close-to-the-ceilingmanner. Using the standard method, the hanger ball/downrod assembly will suspend the fan several inches below the ceiling cover. Using theclose-to-the-ceilingmethod, the ceiling cover installs directly on the fan motor housing, thus mounting the fan3-1/2inches closer to the ceiling than the standard method. In no case should the fan blades be lower than seven feet above the floor. Depending on your desired mounting method, proceed to “INSTALLING HANGER BALL/DOWNROD ASSEMBLY” for standard mounting, or to “INSTALLING CEILING COVER ON FAN MOTOR HOUSING” forclose-to-the-ceilingmounting.

Removal Of The

Hanger Bracket

1.Loosen the two screws in the keyholes slots of the ceiling cover. Remove and retain the other two screws and lockwashers (Figure 1).

2.Turn the ceiling cover and remove the hanger bracket.

HANGER

BRACKET CEILING

COVER

REMOVE AND RETAIN

TWO SCREWS AND LOCKWASHERS LOOSEN THE TWO SCREWS IN THE KEYHOLE SLOTS

Figure 1

Installing The Hanger

Ball/Downrod Assembly

(For Standard Mounting)

1.Pass the 42" motor leads through the opening in the ceiling cover. Be sure the cover is oriented correctly.

2.Separate, untwist and unkink the three motor leads. Route the motor leads through the hanger ball/downrod assembly.

3.Loosen the two setscrews in the motor coupling. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the hanger ball to make sure the clevis pin is properly installed.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.

4.While pulling up on the hanger ball, securely tighten the two setscrews in the motor coupling (Figure 2).

NOTE: The setscrews must be properly installed as described above, or fan wobble could result.

5.The fan comes with blue, black and white leads that are 42” long. Measure up approximately 6 to9-inchesabove top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation1/2-inchfrom end of leads.

 

HANGER

DECORATIVE

BALL/DOWNROD

ASSEMBLY

CAP

 

HAIRPIN

CEILING

COVER

CLIP

SETSCREW

 

 

CLEVIS

 

PIN

MOTOR COUPLING

 

 

SETSCREW

Figure 2

4

U.L. Model No.: CF712

Installing The Ceiling Cover

On The Fan Motor Housing

(For Close-to-the-CeilingMounting)

1.Remove and retain three screws from the top of the motor housing (Figure 3A).

2.Position the rubber gasket (supplied in parts bag) on the motor housing (small holes in gasket centered over the screw holes in the housing) (Figure 3B).

REMOVE SCREWS (3)

INSTALL GASKET

Figure 3A

Figure 3B

3.Gently pry the decorative cap (Figure 2) from the ceiling cover. Align the holes in the ceiling cover with the holes in the motor housing and secure using the three screws (Figure 4).

RUBBER

SCREW (3)

GASKET

 

Figure 4

4.The fan comes with blue, black and white leads that are 42” long. Measure up approximately 6 to 9-inchesabove the motor coupling. Cut off excess leads and strip back insulation1/2-inchfrom ends of leads.

Installing The

Hanger Bracket

!WARNING

The fan must be hung with at least 7' of clearance from floor to blades (Figure 5).

7'

MIN.

!WARNING

The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”.

1.Unscrew (but do not remove) the two mounting screws in the outlet box (Figure 6). Position the hanger bracket on the outlet box so that the T-slotsin the hanger bracket are aligned with the outlet box screws.

 

OUTLET BOX

 

LOOSEN TWO

T-SLOT

SCREWS (SUPPLIED

WITH OUTLET BOX)

SLIDE THE HANGER

BRACKET ONTO

THE OUTLET BOX

SCREWS, THROUGH

THE T-SLOT

HANGER

BRACKET

Figure 6

!WARNING

To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

NOTE: The hanger bracket must be mounted flush with the ceiling in order for the ceiling cover to install properly. If necessary, use leveling washers (not supplied) between the outlet box and the hanger bracket.

2.Slide the hanger bracket onto the outlet box screws. Center the bracket over the outlet box and then securely tighten the screws (Figure 7).

!WARNING

Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, use leveling washers between the hanger bracket and the outlet box until the bracket is flush with the ceiling. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.

 

SECURELY

 

TIGHTEN

HOOK

SCREWS

 

Figure 7

HANGER BRACKET

 

Figure 5

FLOOR

5

U.L. Model No.: CF712

 

Hanging The Ceiling Fan

(Standard Method Using

Hanger Ball/Downrod)

1.Carefully lift the fan assembly and seat the hanger ball in the hanger bracket (Figure 8). The tab on the hanger bracket must seat in the groove in the hanger ball.

!WARNING

Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

!WARNING

To avoid fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.

HOOK

TAB

GROOVE

Figure 8

HANGER

BRACKET

HANGER

BALL

Hanging The Ceiling Fan

(Close-to-the-CeilingMethod with Ceiling Cover Installed on

the Motor Housing)

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local Codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

!WARNING

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.

Wiring The Ceiling Fan

1.Carefully lift the fan assembly up to the hanger bracket. Pass the hook on the hanger bracket (Figure 8) through one of the screw holes (not the slots) in the ceiling cover (Figure 9). The hook must pass from the inside of the ceiling cover to the outside. The hook will hold the fan assembly while connecting the wiring.

!WARNING

The hook must pass through the screw hole in the ceiling cover from the inside to the outside. Any other hanging method may cause the hook to break and the fan to fall.

HOOK ON HANGER BRACKET MUST PASS THROUGH SCREW HOLE IN CEILING COVER, INSIDE OF BRACKET TO OUTSIDE OF BRACKET

CEILING

COVER

If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.

!WARNING

To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.

1.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation) (Figure 10). Securely connect wires using wire connectors supplied.

NOTE: When wiring the ceiling fan for close-to-the-ceilingmounting, there will be no green grounding lead from the hanger ball.

Figure 9

6

U.L. Model No.: CF712

2.Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 10). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 10). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box.

WIRE CONNECTOR

BLACK

SUPPLY (HOT)

BLUE

FAN WIRE

BLACK

FAN WIRE

WHITE SUPPLY

NEUTRAL)

WHITE FAN WIRE

Figure 10

SUPPLY

GROUND WIRE

GREEN GROUND

WIRE FROM HANGER

BRACKET

GREEN GROUND

WIRE FROM HANGER

BALL

!WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

Installing The

Ceiling Cover

NOTE: When installing the ceiling fan using the close-to-the-ceilingmethod, carefully lift the fan assembly from the hook on the hanger bracket and proceed as follows.

1.Lift the ceiling cover up to the hanger bracket. Engage the slots in the ceiling cover with the loosened screws in the bracket and turn the cover counterclockwise (Figure 11). Be sure that the lockwashers are between the screw heads and the ceiling cover.

2.Reinstall the other two screws and lockwashers; tighten all screws securely.

REINSTALL SCREW AND

TIGHTEN SCREW

LOCKWASHER

 

LOOSEN THIS

SCREW

CEILING

COVER

Figure 11

!WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

3.Cut the speed control switch pull chain and the light switch pull chain to the desired lengths. Connect the wood pendants (supplied) to the pull chains by sliding the pendants (small hole first) onto the pull chains. Then attach the chain couplings (supplied) to the end of the chains and allow the pendants to fall down over the couplings.

Installing The Fan Blades

!WARNING

To reduce the risk of personal injury, do not bend the blade flanges when installing the flanges, balancing the blades, or cleaning the fan. Do not insert foreign objects between rotating fan blades.

1.Make sure the three rubber grommets are firmly seated on each of the blade flanges. Then mount the blade flanges to the fan blades using three M5 x 6 washer head blade screws per blade (Figure 12).

M5 x 6 WASHER

HEAD BLADE SCREW (3 Per Blade)

FAN BLADE

ALIGNMENT POST

BLADE FLANGE

RUBBER GROMMETS

Figure 12

7

U.L. Model No.: CF712

2.Mount one blade assembly to the motor hub by mating the alignment post (Figure 12) of the flange with one of the alignment slots in the motor hub (Figure 13). Then tighten the two captive screws in the flange to secure the flange to the motor hub. Repeat this procedure for the other four blade assemblies. Make sure all screws are tightened.

MOTOR HUB

 

BLADE FLANGE

CAPTIVE

ALIGNMENT

SCREW (2)

SLOT

 

Figure 13

Installing The Light Fitter

And Glass

1.Remove and retain the three screws securing the switch housing cover to the switch housing. (Figure 14) Remove and retain the two wire connectors. Remove plug screw.

SCREW (3)

SWITCH

HOUSING

SWITCH REMOVE AND RETAINHOUSING COVER THE TWO WIRE

CONNECTORS

PLUG SCREW

Figure 14

2.Remove and retain the lockwasher and nut from the light fitter. Insert the black and white wires from the light fitter through the center hole in the switch housing cover. Thread the switch housing cover onto the light fitter. Reinstall the lockwasher and nut and tighten securely (Figure 15).

3.Connect the white wire from the ceiling fan to the white wire of the light fitter (Figure 15). Connect the blue wire from the ceiling fan to the black wire of the light fitter. Use wire connectors (previously removed) to make connections.

4.Carefully tuck all wires and splices into the switch housing.

5.Attach the switch housing cover with light fitter to the switch housing using the three previously removed screws.

!WARNING

To avoid fire or electrical shock, be careful not to pinch wires between the switch housing assembly and the cover.

 

SCREW (3)

WHITE WIRE

BLUE WIRE

 

WIRE

WIRE

CONNECTOR

CONNECTOR

WHITE WIRE

 

NUT

BLACK WIRE

 

LOCKWASHER

SWITCH

 

HOUSING

 

COVER

LIGHT FITTER

Figure 15

6.Install three 60-watt(maximum) candelabra base light bulbs (not supplied) into the light fitter sockets (Figure 16).

7.Remove the finial nut and outer bowl cap from the light fitter (Figure 16).

8.Pass the fan switch chain through the bushing in the bowl cap (Figure 16).

!WARNING

To avoid possible fire hazard, do not exceed wattage indicated on the fitter.

FAN SWITCH

CHAIN

LIGHT FITTER

60-WATT

BOWL CAP

CANDELABRA

THREADED NIPPLE

BASE BULBS (3)

 

GLASS BOWL

OUTER BOWL CAP

FINIAL NUT

PENDANTS (2)

LIGHT SWITCH

CHAIN

8 Figure 16

U.L. Model No.: CF712

9.Position the glass bowl over the threaded nipple and seat bowl on bowl cap (Figure 16). Pass the fan pull chain through the bushing in the outer bowl cap and install the cap on the threaded nipple. Install nut finial finger tight.

CAUTION

Be sure that the fan switch chain does not make contact with the light bulbs. If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs.

10.Install pendants onto light fixture chain and fan switch chain using couplings provided.

NOTE: It is advisable to periodically check the tightness of the finial.

Using Your Ceiling Fan

1.Restore electrical power to the outlet box by turning the electricity on at the main fuse box.

2.Check the operation of the light by gently pulling on the light switch pull chain.

3.Check the operation of the fan by gently pulling on the speed control switch pull chain. The operation sequence is as follows:

1st pull - High

3rd pull - Low

2nd pull - Medium

4th pull - OFF

4.Your fan is shipped from the factory with the reversing switch positioned to circulate air downward. If airflow is desired in opposite direction, turn the fan off and wait for the blades to stop turning, then slide the reversing switch to the opposite position, and turn the fan on again. The fan blades will turn in the opposite direction and reverse the airflow.

REVERSING

SWITCH

Maintenance

IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.

Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.

!WARNING

Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.

Accessories

1.Ceiling Fan/Light Controls (see store or catalog).

2.Downrod Extension Kits (see store or catalog).

!WARNING

The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Company. Substitution of parts or accessories not designated for use with this product by Emerson Electric Company could result in personal injury or property damage.

SPEED CONTROL LIGHT PULL PULL CHAIN SWITCH CHAIN SWITCH

9

U.L. Model No.: CF712

! WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.

Trouble Shooting

TROUBLE

 

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

 

1. Fan will not start.

1.

Fuse or circuit breaker blown.

1.

Check main and branch circuit fuses or circuit breakers.

 

 

 

!

WARNING: Make sure main power is turned off.

 

2.

Loose power line connections to the fan, or loose

2.

Check line wire connections to fan and switch wire

 

 

switch wire connections in the switch housing.

 

connections in the switch housing.

 

3.

Reversing switch in neutral position.

3.

Make sure reversing switch position is all the way to one

 

 

 

 

side.

 

 

 

 

 

2. Fan sounds noisy.

1.

Blades not attached to fan.

1.

Attach blades to fan before operating.

 

2.

Screws securing fan blade flanges to motor hub

2.

Check to make sure the screws which attach the fan

 

 

are loose.

 

flanges to the motor hub are tight.

 

 

 

!

WARNING: Make sure main power is turned off.

 

3.

Wire connectors inside switch housing rattling.

3.

Check to make sure wire connectors in switch housing

 

 

 

 

are not rattling against each other or against the interior

 

 

 

 

wall of the switch housing.

 

4.

Motor noise caused by solid-statevariable

4.

Some fan motors are sensitive to signals from Solid-

 

 

speed control.

 

State variable speed controls. If Solid-StateControl

 

 

 

 

is used and motor noise results choose an alternative

 

 

 

 

control method.

 

5.

Screws holding blades to flanges are loose.

5.

Tighten screws securely.

 

 

 

 

 

3. Fan wobbles

1.

Setscrews in motor coupling are loose.

1.

Tighten both setscrews securely in the motor coupling.

excessively.

2.

Setscrew in hanger ball/downrod assembly is

2.

Tighten the setscrew in the hanger ball/downrod

 

 

loose.

 

assembly.

 

3.

Screws securing fan blade flanges to motor are

3.

Check to be sure screws which attach the fan blade

 

 

loose.

 

flanges to the motor are tight.

 

4.

Fan blade flanges not seated properly.

4.

Check to be sure the fan blade flanges seat firmly and

 

 

 

 

uniformly to the surface of the motor.

 

5.

Hanger bracket and/or ceiling outlet box is not

5.

Tighten the hanger bracket screws to the outlet box,

 

 

securely fastened.

 

and/or secure outlet box.

 

6.

Fan blades out of balance.

6.

Interchanging an adjacent (side-by-side)blade pair can

 

 

 

 

redistribute the weight and result in smoother operation.

 

 

 

 

 

10