READ AND SAVE THESE INSTRUCTIONS

 

 

CF711 shown

42” Model No.

50” Model No.

CF710AB01

CF711AB01

CF711ORB01

CF710AW01

CF711AW01

CF711PB01

CF710BS01

CF711BS01

CF711WB01

CF710ORB01

CF711CK01

CF711WW01

CF710PB01

 

 

CF710WW01

 

 

Net Weight: 15.0 Lbs.

Net Weight: 19.8 Lbs.

BUILDER PLUS Series

Ceiling Fan Owner's Manual

Part No. F40BP72580005

Form No. BP7258-5

 

U.L. Model No.: 42-ANT/52-ANT

!WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.All wiring must be in accordance with the National Electrical Code, “ANSI/NFPA 70-1999” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

NOTE: The CF711 fan is suitable for use with solid-state speed controls.

WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label.

You should record this data above and keep it in a safe place for future use.

2

U.L. Model No.: 42-ANT/52-ANT

This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One 1/4” blade screwdriver

One wire stripper

Three wire connectors (supplied).

 

Four 60-watt (max.) intermediate base bulbs (CF711) Three 60-watt (max.) intermediate base bulbs

(CF710)

MATERIALS

Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

 

 

!WARNING

Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 6). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.

2.Remove the fan housing assembly from the protective plastic bag. Turn the upper styrofoam pad over and carefully place the fan motor assembly into the recess in the pad with the top of the motor facing up.

1.Check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

a.Fan motor assembly

b.Five fan blades

c.One ceiling cover

d.Five blade flanges

e.One hanger ball/downrod assembly

f.One hanger bracket

g.One switch housing cover

h.Glass shades (3 or 4)

i.One loose parts bag containing:

1.Sixteen M5 x 6 washer head blade screws

2.One rubber gasket

3.Two wood pendants

4.Two couplings

5.Three wire connectors

6.One clevis pin

7.One hairpin clip

8.One Phillips round head flange screw

LOOSE

 

PARTS

FAN MOTOR

BAG

ASSEMBLY

 

GLASS

HANGER

BRACKET

SHADES

 

(3 or 4)

 

HANGER BALL/

 

CEILING

DOWNROD

 

ASSEMBLY

 

COVER

SWITCH HOUSING

FAN

 

COVER

BLADE

 

BLADES

 

FLANGES

 

 

3

U.L. Model No.: 42-ANT/52-ANT

Emerson CF710ORB01, CF710AB01, CF710WW01, CF711AW01, CF711ORB01 User Manual
U.L. Model No.: 42-ANT/52-ANT

IMPORTANT

Your ceiling fan is designed to be installed either in the standard manner, or in the close-to-the-ceiling manner. Using the standard method, the hanger ball/downrod assembly will suspend the fan several inches below the ceiling cover. Using the close-to-the-ceiling method, the ceiling cover installs directly on the fan motor housing, thus mounting the fan 3-1/2 inches closer to the ceiling than the standard method. In no case should the fan blades be lower than seven feet above the floor. Depending on your desired mounting method, proceed to “INSTALLING HANGER BALL/DOWNROD ASSEMBLY” for standard mounting, or to “INSTALLING CEILING COVER ON FAN MOTOR HOUSING” for close-to-the-ceiling mounting.

 

HANGER

DECORATIVE

BALL/DOWNROD

ASSEMBLY

CAP

 

HAIRPIN

CEILING

COVER

CLIP

SETSCREW

 

 

CLEVIS

 

PIN

MOTOR COUPLING

 

 

SETSCREW

Figure 1

Installing The Hanger

Installing The Ceiling Cover

Ball/Downrod Assembly

On The Fan Motor Housing

(For Standard Mounting)

(For Close-to-the-Ceiling Mounting)

 

1.Pass the 42” motor leads through the opening in the ceiling cover. Be sure the cover is oriented correctly.

2.Separate, untwist and unkink the three motor leads. Route the motor leads through the hanger ball/downrod assembly.

3.Loosen the two setscrews in the motor coupling. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 1). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the hanger ball to make sure the clevis pin is properly installed.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.

4.While pulling up on the hanger ball, securely tighten the two setscrews in the motor coupling (Figure 1).

NOTE: The setscrews must be properly installed as described above, or fan wobble could result.

5.The fan comes with blue, black and white leads that are 42” long. Measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.

1.Remove and retain three screws from the top of the motor housing (Figure 2A).

2.Position the rubber gasket (supplied in parts bag) on the motor housing (small holes in gasket centered over the screw holes in the housing) (Figure 2B).

REMOVE SCREWS (3)

INSTALL GASKET

Figure 2A

Figure 2B

3.Gently pry the decorative cap (Figure 1) from the ceiling cover. Align the holes in the ceiling cover with the holes in the motor housing and secure using the three screws (Figure 3).

RUBBER

SCREW (3)

GASKET

 

Figure 3

4.The fan comes with blue, black and white leads that are 42” long. Measure up approximately 6 to 9-inches above the motor coupling. Cut off excess leads and strip back insulation 1/2-inch from ends