Emerson CF2000WB02, CF2000WW02, CF2000ORB02, CF2000AB02, CF2000AW02 User Manual 2

...
0 (0)

READ AND SAVE THESE INSTRUCTIONS

Model No.

CF2000AB02

CF2000AW02

CF2000BC02

CF2000ORB02

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label.

You should record this data above and keep it in a safe place for future use.

CF2000PW02

CF2000WB02

CF2000WW02

Max. Weight: 26.0 Lbs.

With Blades

MAUI BAY

Ceiling Fan Owner's Manual

Part No. F40BP73230001

Form No. BP7323-1

 

U.L. Model No.: CF2000

 

 

!WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-1999” and Local Electrical Codes. Use the National Electrical Code if Local Electrical Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric, Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric, Co could result in personal injury or property damage.

WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

 

TABLE OF CONTENTS

Page

 

 

Rules for Safe Use & Installation

.............................................................................................................................

2

Tools Needed for Assembly .....................................................................................................................................

 

3

Unpacking Instructions.............................................................................................................................................

 

3

Assembly Instructions ..............................................................................................................................................

 

4

Electrical Requirements ...........................................................................................................................................

 

5

How to Hang Your Ceiling Fan.................................................................................................................................

 

5

How to Wire Your Ceiling Fan..................................................................................................................................

 

6

Installing Fan Blades................................................................................................................................................

 

6

Using Your Ceiling Fan ............................................................................................................................................

 

7

Attaching Light Kit ....................................................................................................................................................

 

7

Maintenance.............................................................................................................................................................

 

7

Trouble Shooting......................................................................................................................................................

 

8

Repair Parts ........................................................................................................................................................

 

9-10

Warranty.................................................................................................................................................................

2

11

 

 

This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

Five wire connectors (supplied)

One wire stripper

MATERIALS

Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

!WARNING

Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 6). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric, Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric, Co. could result in personal injury or property damage.

1.Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following:

a.Fan motor and housing assembly

b.One motor cover

c.One ceiling cover

d.Five blade flanges

e.One hanger ball/downrod assembly

f.One hanger bracket

g.One switch housing cover

h.One loose parts bag containing:

1.One setscrew

2.One setscrew wrench

3.Eleven 10-32 x 5/8" oval head screws

4.Two 1” threaded studs

5.Two 1-1/4” threaded studs

6.Four knurled knobs

7.Five wire connectors

8.Two 8-32 x 3/8" screws

9.One pull chain pendant and coupling

10.One hairpin clip

11.One clevis pin

12.Four lockwashers

13.Twenty-one 10-32 x 3/8" pan head screws

14.Twenty-one flat washers

NOTE: Place the parts from the loose parts bags in small containers to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.

NOTE: Fan blades are ordered separately and are packaged in separate carton.

FAN MOTOR AND

HOUSING ASSEMBLY

 

HANGER BALL/

LOOSE

DOWNROD

PARTS

ASSEMBLY

BAG

 

 

HANGER

BLADE

BRACKET

FLANGES

 

 

MOTOR

 

COVER

CEILING

 

COVER

SWITCH

 

 

HOUSING

 

COVER

3

Emerson CF2000WB02, CF2000WW02, CF2000ORB02, CF2000AB02, CF2000AW02 User Manual 2

Assembly Instructions

1.Remove the fan motor and housing assembly from styrofoam packaging and position it so that the top of the motor is facing you.

2.Separate, untwist and unkink the three motor leads. Route the motor leads through the hanger ball/downrod assembly and seat the downrod in the motor coupling (Figure 1).

MOTOR LEADS (BLACK, WHITE,

AND BLUE)

HANGER BALL/

DOWNROD ASSEMBLY

MOTOR

COUPLING FAN MOTOR AND

HOUSING ASSEMBLY

Figure 1

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 2) could result in the fan falling.

3.Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). (Pin and clip are supplied in loose parts bag.) The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the hanger ball to make sure the clevis pin is properly installed.

4.Install the setscrew (supplied) in the motor coupling (Figure 2). While pulling up on the hanger ball, tighten the setscrew using the setscrew wrench (supplied).

NOTE: The setscrew must be properly installed as described above, or fan wobble could result.

5.Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 3). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 8.

PIN

HANGER BALL

DOWNROD

SETSCREW

 

Figure 3

6.Screw two 1” threaded studs (supplied) into the motor (Figure 4). Leave approximately 7/8” of the stud extending above motor. Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude; install two lockwashers and knurled knobs (supplied) to secure the cover.

NOTE: Make sure the connected red leads, the connected brown leads, and the white lead are completely inside the motor cover and not pinched between the motor cover and the motor.

KNURLED KNOB

LOCKWASHER

MOTOR COVER

1" THREADED STU 7/8"

DOWNROD

HANGER BALL

HAIRPIN

CLIP

SETSCREW

MOTOR

COUPLING

CLEVIS PIN

WHITE LEAD

CONNECTED

BROWN LEADS

HAIRPIN

CLEVIS PIN

MOTOR

CLIP

COUPLING

CONNECTED

 

RED LEADS

SETSCREW

 

Figure 4

MOTOR

7.Position the ceiling cover over the downrod. Be sure the cover is oriented correctly, with the large opening at the top (Figure 5).

PIN

HANGER BALL

DOWNROD

Figure 2

Figure 5

4

 

Loading...