Emerson CF144CRM00, CF144BS00, CF152ORB00, CF144WW00, CF144ORB00 User Manual

...
0 (0)

BP7407 44" & 52" Curva Sky 1/11/10 9:54 PM Page 1

READ AND SAVE THESE INSTRUCTIONS

CURVA SKY

44” & 52” Damp & Wet

Location Snugger Ceiling Fan

Owner's Manual

44” Model Numbers

52” Model Numbers

for Damp Locations

for Damp Locations

CF144BS00

CF152BS00

Brushed Steel

Brushed Steel

CF144CRM00

CF152CRM00

Chrome

Chrome

44” Model Numbers

52” Model Numbers

for Wet Locations

for Wet Locations

CF144WW00

CF152WW00

Appliance White

Appliance White

CF144ORB00

CF152ORB00

Oil Rubbed Bronze

Oil Rubbed Bronze

Net Weight: 18.5 Lbs.

Net Weight: 19.4 Lbs.

Part No. F40BP74070000

Form No. BP7407

 

UL Model No.: CF144 & CF152

BP7407 44" & 52" Curva Sky 1/11/10 9:54 PM Page 2

!WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.The installation is to be in accordance with the National Electrical Code, ANSI/NFPA 70-2008 and Local Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most

outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

5.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

NOTE: This fan is suitable for use with solid-state speed controls.

WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control Model No. UC8013G, manufactured by Rhine Electric Co., Ltd.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING: To reduce the risk of electric shock, this fan must be installed with an isolating remote control/switch.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.

2

UL Model No.: CF144 & CF152

BP7407 44" & 52" Curva Sky 1/11/10 9:54 PM Page 3

THE FAN MODELS CF144BS, CF144CRM, CF152BS & CF152CRM ARE SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD.

THE FAN MODELS CF144WW, CF144ORB, CF152WW & CF152ORB ARE SUITABLE FOR WET LOCATIONS SUCH AS PORCHES, PATIOS, AND DECKS.

This Manual is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver One wire stripper

One stepladder

Materials

Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

!WARNING

Before assembling your ceiling fan, refer to section on proper method of wiring your fan (Page 7). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

1. Open carton containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

a.Fan motor assembly

b.One ceiling trim ring

c.One ceiling mounting plate

d.Three fan blades

e.One lower housing

f.One light kit plate

g.One glass shade

h.One no-light cover plate

i.One 6-speed electronic receiver control with parts bag

j.One 6-speed handheld transmitter with wall bracket

k.Two 50W halogen mini candelabra bulbs

l.One loose parts bag containing:

1.Three 12 ga. wire connectors

2.One spare M5 x 10mm pan head ceiling cover screw

3.Ten M5 x 16mm flange head blade screws

4.One spare M4 x 10mm pan head screw for lower housing and light kit

5.One balancing kit

3

UL Model No.: CF144 & CF152

Emerson CF144CRM00, CF144BS00, CF152ORB00, CF144WW00, CF144ORB00 User Manual

BP7407 44" & 52" Curva Sky 1/11/10 9:54 PM Page 4

A. FAN MOTOR

ASSEMBLY B. CEILING

TRIM RING

E. LOWER

HOUSING

C. CEILING

MOUNTING PLATE

D. FAN BLADES (3)

I. 6-SPEED

ELECTRONIC

RECEIVER J. 6-SPEED

HANDHELD

TRANSMITTER

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost.

2. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface.

F. LIGHT

KIT PLATE

H. NO-LIGHT

COVER PLATE

K. 50W MINI CANDELABRA HALOGEN BULBS

L. LOOSE

PARTS BAG

PROTECTIVE

PLASTIC BAG

4

UL Model No.: CF144 & CF152

BP7407 44" & 52" Curva Sky 1/11/10 9:54 PM Page 5

Electrical Requirements

How to Assemble Your

 

Ceiling Fan

IMPORTANT: Your ceiling fan will not function properly, and may be damaged, if used with any wall dimmer switch or control other than the Emerson Electric Fan/Light Remote Control supplied with the fan.

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

1.Position the fan motor assembly upside down in preparation for mounting the three fan blades.

2.Slide blade through blade slot in fan housing assembly. Mount blade to fan housing using three M5 x 16mm flange head blade screws (Figure 1).

NOTE: Take care not to scratch fan housing assembly when installing blades.

M5 x 16mm FLANGE HEAD BLADE SCREWS (3 per blade)

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse or circuit breaker box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

 

FAN

FAN

HOUSING

BLADE

 

SLIDE FAN BLADE

INTO BLADE

CENTER SLOT

BLADE

SLOT

Figure 1

3. Complete the remaining two blades installation per the above instructions.

4. Remove one of the three screws in the motor housing assembly and loosen the remaining two screws (Figure 2).

5. Attach the lower housing assembly to the fan motor using the two key slot holes (Figure 2). Secure the lower housing assembly by tightening the two screws. Reinstall the screw that was previously removed.

REMOVE M4 x 10mm

PAN HEAD SCREW

LOWER HOUSING

Ceiling Fan Procedures

 

General

KEY HOLE

Your Emerson ceiling fan comes supplied

SLOT (2)

 

with a Fan/Light Remote Control which

 

consists of a receiver mounted inside the

 

ceiling cover of the fan motor housing.

 

This system allows you to regulate your

Figure 2

ceiling fan speed and light intensity.

 

5

UL Model No.: CF144 & CF152

Loading...
+ 11 hidden pages