Emerson PowerPlex Brochure

0 (0)

power and Control products

quick response program.

Emerson PowerPlex Brochure

Custom configured Products Ready for Shipment in One to Ten Business Days.

Appleton’s Quick Response Program places select power and control products at your fingertips. Appleton gets the right product for your application to you quickly including a range of customconfigured control stations, panelboards, motor starters, disconnect switches, circuit breakers, enclosures and junction boxes.

All of Appleton’s power and control products meet the demanding needs of hazardous and industrial environments. Trust Appleton to quickly deliver safe and durable products to applications across your facility.

Page 3

power and Control products

Description

Certifications

Page

Distribution Equipment

PowerPlex™ PowerPlex Factory Sealed Lighting Distribution Panelboards

R

5

C US

D2P Factory Sealed Circuit Breaker Panelboards

 

5

 

 

 

AEB Series Bolted Combination and Non-Combination Full Voltage Motor Starters

C US

6

 

R

 

 

 

 

AEB Series Full Voltage Motor Starters

 

6

AEB Series Combination Full Voltage Motor Starters With Thermal Magnetic Circuit Breakers

 

6

ACSE Series Manual Motor Starter

 

6

 

 

 

EDS Heavy Duty Disconnect Switch

 

7

 

 

 

AE Series Disconnect Switches

 

7

 

 

 

AE Bolted Circuit Breaker Enclosures

 

8

AJBEW Cast Junction Boxes

 

9

To order the enclosure for use as a control panel substitute AJBEW with ACSEW.

 

Breaker Schedule Form for PowerPlex Panelboards

 

15

Select Internal or External Actuation

 

Breaker Schedule Form for D2P Panelboards

 

16

Junction Box Drill and Tap Schedule and Hinges and Back Pan Requirement Form

 

17

Control Stations

EFD Series

10

 

 

EFD Series Mounting Bodies

10

EFD Series Factory Sealed Covers with Devices Installed

10

Contender Series

11

 

 

Contender Series Mounting Bodies

11

Contender Series Covers with Devices Installed

11

N1 Intraground Series

12

 

 

 

N1

Intraground Series Push Button Control Stations

12

N1

Intraground Series Non-Metallic Selector Switches

12

N1

Intraground Series Non-Metallic Push Button and Push Button/Pilot Light Control Stations

12

N1

Intraground Series 20 Amp Receptacles with Non-Metallic Mounting Box

13

N1 Intraground Series NCP Plugs

13

 

 

 

N1

Intraground Series Accessories and Parts

13

N1

Intraground Series Non-Metallic Tumbler Switches

14

For questions pertaining to the Quick Response Program or to place an order contact your local Appleton Representative or:

Customer Service - U.S. Domestic

Customer Service - Canada

Phone: 800-722-8515

Phone: 800-621-1506

Fax: 800-356-4714

Fax: 800-465-4903

Email: egseg.customerservice@emerson.com

Email: egs.canadacs@emerson.com

Page 4

panelboards

powerPlex™ Factory Sealed Lighting Distribution Panelboards:

Explosionproof, Dust-Ignitionproof, Watertight, Corrosion Resistant

R

CUS

• Certifications and Compliances

UL Standards: ANSI/UL 67, ANSI/ISA 12.12.01,

ANSI/UL 1203, ANSI/UL 60079-0, ANSI/

UL60079-1, ANSI/UL60079-7

CSA Standards: C22.2 No. 29, C22.2 No. 0,

C22.2 No. 213, CAN E60079-0,

CAN E60079-7, CAN E60079-1

cCSAus Certified: 039199

Class I, Division 2 Group B, C, D Class I, Zone 1 AEx de IIB+H2 T5 Class II, Division 1, Group F, G Class III

Ex de IIB+H2

Type 4X, IP66

Indoor and outdoor protection and control of electrical equipment and circuits that is suitable for use on lighting, heat trace and power circuits. Ideal for placement in wet, corrosive environments or where flammable gases or vapors are likely to be present.

The PowerPlex panelboard features a ground-breaking design that uses individual breaker housings to minimize the downtime and costs associated with servicing circuit breakers in hazardous locations.

Shipped In 5 Business Days.

(Maximum 5 panels per order. No GFI, EPD or HID breakers.)

Include the Completed Breaker Schedule Form with all orders. all breaker positions must be filled.

Internal Actuation Only

Service and

 

 

Number of

 

 

 

Maximum Amps

Cable Range

Wiring System

Breakers

Panel Size

Circuits

Catalog Number

100 Amps Main Lugs Only

 

 

12

C

12

RQSC131L12QRP

100 or 60 Amps Main Breaker

4/0 to #14AWG

120/208V 3Ø AC

RQSC131M12QRP

 

 

 

100 Amps Main Lugs Only

24

D

24

RQSD131L24QRP

 

 

100 or 60 Amps Main Breaker

 

 

RQSD131M24QRP

 

 

 

 

 

 

 

Optional External Actuation

 

 

 

Service and

 

 

Number of

 

 

 

Maximum Amps

Cable Range

Wiring System

Breakers

Panel Size

Circuits

Catalog Number

100 Amps Main Lugs Only

 

 

12

C

12

RQSC131L12QRPEX

100 or 60 Amps Main Breaker

4/0 to #14AWG

120/208V 3Ø AC

RQSC131M12QRPEX

 

 

 

100 Amps Main Lugs Only

24

D

24

RQSD131L24QRPEX

 

 

100 or 60 Amps Main Breaker

 

 

RQSD131M24QRPEX

 

 

 

 

 

D2P Factory Sealed Circuit Breaker Panelboards:

Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

• Certifications and Compliances

Class I, Division 2, Groups B , C , D

UL Standard: UL 877, UL 1203

Class II, Division 1 and 2, Groups E, F, G

UL Classified: E77137

Class III

NEMA 3, 3R, 4, 4X, 5, 7BCD, 9EFG, 12

 

Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions.

Designed for use in Class I, Division 2 areas where ignitable vapors or gases may be present under unusual conditions, or in Class II, Division 1 areas where combustible dusts are present.

Shipped In 10 Business Days.

(Maximum 5 panels per order. No GFI, EPD or HID breakers.)

Include the Completed Breaker Schedule Form with all orders.

Main Lug

Cable

Wiring

Number of

Panel

 

Catalog

Maximum Amps

Range

System

Breakers

Size

Circuits

Number

 

 

Number 4

12

A

12

D2P4A12QRP

 

 

24

B

24

D2P4B24QRP

 

 

120/240V AC

250

250 MCM to 6

36

C

36

D2P4C36QRP

 

Number 5

12

A

12

D2P5A12QRP

 

 

 

 

24

B

24

D2P5B24QRP

 

 

120/208V AC

 

 

36

C

36

D2P5C36QRP

 

 

 

For Groups B and C, all conduits must be sealed adjacent to enclosure.

Page 5

motor starters

AEB Series Bolted Combination and Non-Combination Full Voltage Motor Starters:

Explosionproof, Dust-Ignitionproof, Watertight

• Certifications and Compliances

 

 

 

 

ANSI/UL 508-17th Edition

CAN/CSA C22.2

No. 14

-10

Class I, Division 1 and 2, Groups B, C, D

ANSI/UL 50-11th Edition

CAN/CSA C22.2

No. 25

-1966

Class II, Division 1 and 2, Groups E, F, G

ANSI/UL 1203-4th Edition

CAN/CSA C22.2

No. 30

-M1986

Class III

CAN/CSA C22.2 No. 0 -10

CAN/CSA-C22.2 No. 94 -M91

NEMA 4, 4X, 7BCD, 9EFG

Combination and non-combination motor starters are used in areas where hazardous materials are handled or stored.

These units provide disconnecting means, under voltage protection, circuit protection, and motor running protection.

Shipped In 5 Business Days.

(Maximum 3 starters per order.)

R

CUS

AEB Series Full Voltage Motor Starters:

3 Phase, 60 Hz, Non-Reversing

 

 

Maximum

Standard Conduit

 

Line Voltage

NEMA Size

Horsepower

(inches)

Catalog Number

 

0

5

1-1/2

AE0BA4C1

480

1

10

1-1/2

AE1BA4C1

 

2

25

1-1/2

AE2BA4C1

AEB Series Combination Full Voltage Motor Starters With Thermal Magnetic Circuit Breakers:

3 Phase, 60 Hz, Non-Reversing

Line

 

Maximum

 

Standard Conduit

Control Power

 

Voltage

NEMA Size

Horsepower

Amp Trip

(inches)

Options

Catalog Number

 

0

1

3

1-1/2

 

AE0BB4C1C1T0

 

0

3

7

1-1/2

 

AE0BB4C1C2T0

 

0

5

15

1-1/2

Fused CPT, 50 VA

AE0BB4C1C3T0

 

1

7

15

1-1/2

 

AE1BB4C1C3T1

480

1

10

30

1-1/2

 

AE1BB4C1C4T1

2

12

30

1-1/2

 

AE2BB4C1C4T2

 

 

 

2

25

50

1-1/2

Fused CPT, 200 VA

AE2BB4C1C5T2

 

3

30

50

2-1/2

AE3BB4C1C5T3

 

 

 

3

50

100

2-1/2

 

AE3BB4C1C7T3

 

4

100

150

2-1/2

Fused CPT, 250 VA

AE4BB4C1C8T4

ACSE Series Manual Motor Starter:

Explosionproof, Dust-Ignitionproof, Waterproof

• Certifications and Compliances

CSA Standards: C22.2 No. 14, C22.2

Class I, Division 1 and 2, Groups C and D

UL Standard: UL 1203

No. 25, C22.2 No. 30

Class II, Division 1 and 2, Groups E, F and G

UL Classified: E84577

CSA Certified: 1395785

Class III

 

 

 

NEMA 3, 3R, 7CD

• Explosionproof across-the-line manual motor starters for starting single and polyphase AC or DC motors.

Shipped In 5 Business Days.

(Maximum 5 starters per order.)

 

 

Motor

Maximum

General Electric

Square D

No. of Poles

NEMA Size

Voltage

HP Poly Phase

Catalog Number

Catalog Number

 

 

115

 

 

 

0

200 - 230

3

ACSE040805GE03

ACSE040805SQD03

3

 

380 - 575

5

 

 

 

115

 

 

 

 

 

 

 

1

200 - 230

7-1/2

ACSE040805GE13

ACSE040805SQD13

 

 

380 - 575

10

 

 

Page 6