Heat Pump

ACCURACY

OPTIMUM COMFORT

AND PERFORMANCE

Programmable Non-Programmable

Changing the World of Heat Pump Thermostats for the Better.

We’ve improved the best-sellingdigital thermostat with new styling and enhanced home comfort features, specially designed for heat pump applications. It now offers more control, more convenience and more value than the competition. And it’s backed with the reputation ofWhite-Rodgers— pioneers in home comfort since 1937.

More Accuracy and Control. If you’re in the process of upgrading a multi-stage, heat pump or single stage system, don’t forget the “brain” for your new system…your thermostat. Our White-Rodgers 80 Series can maintain a set temperature to within one degree. Plus, there’s a permanent memory that saves all programs and settings during a power loss.

Comfort and Convenience with Versatility.

The programmable model delivers perfect comfort, as it automatically changes to the temperature you selected for wake-up,during the day, evening hours and while you sleep. You can also configure it with minimum and maximum temperature range for cooling or heating. The new 40% larger lighted display makes for clearerlow-lightviewing.

Maximum Energy Savings. Program heating and cooling times to cut energy use, not comfort. You can save up to 33% in energy costs, depending on your home’s location, climate and program selections.

Now you can have it all…energy savings, with comfort and convenience! See the back to find out how this best-sellergives you more of what you want in a universal thermostat.

White-Rodgers

1F82-261

Heat Pump

5/1/1 Day Programmable

80 Series Heat Pump Thermostats

 

 

1F89-211

®

 

Heat Pump

 

Non-Programmable

• 5/1/1 Day Programmable or Non-Programmable• Hardwired

 

 

 

 

 

Programming (1F82-261)

Choice of 5/1/1 day programmable or non-programmable

4 time and 4 temperature settings per program (heat & cool)

Energy savings up to 33%

Patented pre-programmedsoftware simplifies time and temperature programming

Display

60% larger LCD with improved contrast for easier reading

Lighted display for easier low-lightviewing

Terminal Designations

Comfort & Convenience

Performance

Permanent program retention during

Selectable Energy Management Recovery

power loss, no batteries needed

(1F82-261)

Indefinite setpoint Hold or programmable

Powerful next-generationmicroprocessor

timed Hold up to 8 hours (1F82-261)

Meets ENERGY STAR® specifications(1F82-261)

Air filter change indicator

Meets California Building Code, Title 24

Simple menu to activate optional features

(1F82-261)

Temporary temperature override until next

Fast (FA) or slow (SL) heating cycle anticipation

program period (1F82-261)

B or O terminal (selectable)

Soft-touchkeypad

Compressor lockout protection (optional)

Maintains room temperature differential

 

within +/- 1°

 

Display temperature recalibration (+/- 4°)

 

 

 

R

C

W2

Y

G B/O

E

L

 

 

 

 

 

 

 

 

 

 

 

 

 

24V Hot

24V

Auxiliary

Compressor

Blower/Fan

Reversing

Emergency

System

 

Common

Heat

 

 

Relay

 

 

Valve

Heat Relay

Monitor

 

Relay

 

 

(Stg. 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

3.8"H x 6.1"W x 1.1"D

Electrical Specifications

Rating

20 to 30 VAC, 50/60 Hz or DC

0.05 to 1.2 Amps (load per terminal)

1.5 Amps maximum load (all terminals combined)

Standard Systems

Heat Pump—2stage heat, 1 stage cool Single stage heat pump

Thermal Specifications

Setpoint Temperature Range: 45° to 90°F (7° to 32°C)

Rated Differential:

0.6° to 1.6°F with adjustable anticipation

Operating Ambient Temperature: 32° to 105°F (0° to 40°C)

Operating Humidity Range: 90% non-condensingmaximum

Shipping Temperature Range: -4°to 150°F(-20°to 65°C)

Accessories

Wall Plate F61-2500(7.6"W x 4.8"H)

Thermostat Guard F29-0231

(For additional guard options refer to White-Rodgerscatalog)

For Additional Information

Visit www.white-rodgers.com

Stages Heat/Cool

Programs

Model

 

Applications

 

 

Selectable Performance Features

 

 

 

Comfort & Convenience Features

 

by System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single

Multi-

Heat

Program

Model

Gas/Oil/

3 Wire

Millivolt

Thermostat

 

 

Energy

Programmable

Energy

Diplay

Alkaline

 

 

Furnace Lockout

Memory

 

Auto

Program

Lighted

Cool

Back-up

Warranty

Stage

Stage

Pump

Options

Number

Electric

Zone

Compatible

Power

Changeover

Override

Management

Fan

Star

Size

Battery Life

Display

Savings

Ignition

P-Permanent

(Years)

 

 

 

 

 

 

Valve

 

Source*

 

 

Recovery

 

 

(sq. in.)

(Years)

 

 

Module Reset

B-Battery

 

 

 

2/1

5+1+1

1F82-261

 

 

 

H

 

 

 

 

 

1.8

2+

 

 

 

P

1

 

 

2/1

Ø

1F89-211

 

 

 

H

 

 

 

 

 

1.8

2+

 

 

 

P

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* H = Hardwire (Requires Common)