ELKAY EDFPB117C, EDFPBM117C, EDFPB117RAC, EDFPBM117RAC, EDFPBV117C INSTALLATION, CARE & USE MANUAL

...
0 (0)
ELKAY EDFPB117C, EDFPBM117C, EDFPB117RAC, EDFPBM117RAC, EDFPBV117C INSTALLATION, CARE & USE MANUAL

EDFPB117C, EDFPBM117C, EDFPB117RAC, EDFPBM117RAC, EDFPBV117C,

EDFPBMV117C, EDFPBV117RAC, EBFPBMV117RAC

INSTALLATION, CARE & USE MANUAL

SWIRLFLOT M fountains with FLEXI-GUARDT M

EDFPBM(V)117C

EDFPBM(V)117RAC

INSTALLER

! CAUTION: Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes.

! WARNING: When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference.

!WARNING: Service to be performed by authorized service personnel only.

NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an “electrolysis” effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water.

When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and may occur outside the building or area in which the unit is being installed.

This condition can be avoided (in most cases) by using recommended materials during installation. Any drain fittings provided by the installer should be made of plastic which will electronically isolate the fountain from the remainder of the building’s plumbing circuits.

Page 1

97922C (Rev. E - 3/05)

EDFPB117C, EDFPBM117C, EDFPB117RAC, EDFPBM117RAC, EDFPBV117C,

EDFPBMV117C, EDFPBV117RAC, EBFPBMV117RAC

Optional

Figure 1 - Rough-in EDFPBM(V)117C

Figure 2 - Rough-in Assembly EDFPBM(V)117C

LEGEND

A = Water Inlet Location Left Or Right Side. 3/8” O.D. Unplated Copper Tube Connect.

B = Fountain Waste Location Left Or Right Side. Waste Is Shown in Wall But May Be Behind Wall. 1-1/4” O.D. Drain (Trap Not Furnished)

C = Opening For Optional AP-99 Access Panel

Note: Reinforce The Wall In The Shaded Areas.

97922C (Rev. E - 3/05)

Page 2

EDFPB117C, EDFPBM117C, EDFPB117RAC, EDFPBM117RAC, EDFPBV117C,

EDFPBMV117C, EDFPBV117RAC, EBFPBMV117RAC

Optional

Figure 3 -Rough-in EDFPBM(V)117RAC

Figure 4 -Rough-in Assembly EDFPBM(V)117RAC

LEGEND

A = Water Inlet Location Left Or Right Side. 3/8” O.D. Unplated Copper Tube Connect.

B = Fountain Waste Location Left Or Right Side. Waste Is Shown in Wall But May Be Behind Wall. 1-1/4” O.D. Drain (Trap Not Furnished)

C = Opening For Optional AP-99 Access Panel

Note: Reinforce The Wall In The Shaded Areas.

Page 3

97922C (Rev. E - 3/05)