PROFESSIONAL LAUNDRY
Washer extractor
W4850H
Features and benefits
•Clarus Control® – programmable microprocessor with 9 fixed and up to 192 programs to allow free programming
•High extraction for efficient dewatering
•Frequency-controlled motor for optimal washing
•Supplied with 8 + 5 signals for liquid detergents
•Eight connections for liquid detergents
•Large door opening for easy loading and unloading
•All critical parts made from stainless steel to provide a high level of corrosion resistance
•Powder painted galvanised steel side panels
•Bearing seals lubricated with oil to ensure a long service life. Empty container alarm
•Direct steam heating.
•Low noise level for pleasant working environment
•Designed for easy servicing and maintenance
Main options
•Forward or forward/backward tilting with full reversing function
•Noise/heat insulation
•Test tap with level tube
•Two drain valves for recovering water/wash solution
•Five-compartment injector for powder detergent
(located at the front or on the right hand side of the machine)
•Third water valve
•Large water valves
•Integrated weighing system (IWS)
•Connection for intelligent detergent system (DMIS)
•Connection to CMIS
Main specifications |
|
|
W4850H |
|
Max. capacity |
|
|
kg/lb |
90/200 |
Drum, |
volume |
|
litre/ft3 |
850/30 |
|
diameter |
|
ø mm/inch |
1220 / 48 1/16 |
Extraction |
|
|
rpm |
720 |
G-factor |
|
|
|
350 |
Heating alternatives |
steam |
|
x |
|
|
|
non-heated |
|
x |
|
|
electricity |
kW |
– |
Consumption data ”Normal 60°C” * |
|
|
||
Total time (cold+hot/cold) |
|
min |
45/50 |
|
Water consumption (cold/hot) |
|
litre |
713/125 |
|
|
|
|
gallon |
188/33 |
Energy consumption (motor/heating) |
kWh |
2.3/– |
||
Steam consumption (cold/hot) |
|
kg/lbs |
10/22 |
|
Steam consumption (cold) |
|
kg/lbs |
19/41.9 |
|
* Water temperature 59°F cold water and 149°F hot water. |
|
|
||
|
|
|
|
|
Certified in accordance with ISO 9001 and ISO 14001 and approved IP 24D. Certified in accordance with UL/ETL standards.
Electrical connections
Heating |
Main voltage |
|
Heating |
Total |
Recommended |
alternative |
|
|
power |
power |
fuse |
|
|
Hz |
kW |
kW |
A |
Steam or |
208-240V 3 ~ |
60 |
- |
6.3 |
30 |
Non heated |
400/480V 3 ~ |
60 |
- |
6.3 |
15 |
Water, steam and air connections |
|
W4850H |
Water valves |
inch |
1 1/4 |
Rec. Water pressure |
psi |
30-90 |
Function limits for water valve |
psi |
10-145 |
Capacity at 300 kPa |
l/min / gallon/min |
150/37 |
Drain valve |
ø mm/inch |
110 / 4 5/6 |
Draining capacity |
l/min / gallon/min |
400/100 |
Steam valve |
inch |
1 1/4 |
Rec. Steam pressure |
psi |
7-40 |
Function limits for steam valve |
psi |
8-120 |
Compressed air |
inch |
1/8 |
Air pressure |
psi |
30-60 |
Air consumption |
l/h / gallon/h |
20/5 |
Five-compartment detergent injector |
inch |
3/4 |
|
|
|
Floor requirements |
|
|
Frequency of the dynamic force |
Hz |
12.0 |
Floor load at max extraction |
kN |
25.9 ± 1.5 |
|
lbs force |
5830 ± 340 |
|
|
|
Sound levels |
|
|
Sound level |
dB(A) |
73 |
Sound level, with insulation |
dB(A) |
< 70 |
|
|
|
Heat emission |
|
|
% of installed power, max 90° |
|
6.7 |
|
|
|
Shipping data |
|
|
|
net, kg/lbs |
2200/4850 |
Shipping volume |
m3/ft3 |
7.6/269 |