Features and benefits

Clarus Control® – programmable microprocessor with 9 fixed and up to 192 programs to allow free programming

High extraction for efficient dewatering

Frequency-controlled motor for optimal washing

Supplied with 8 + 5 signals for liquid detergents

Eight connections for liquid detergents

Large door opening for easy loading and unloading

All critical parts made from stainless steel to provide a high level of corrosion resistance

Powder painted galvanised steel side panels

Bearing seals lubricated with oil to ensure a long service life. Empty container alarm

Direct steam heating.

Low noise level for pleasant working environment

Designed for easy servicing and maintenance

Main options

Forward or forward/backward tilting with full reversing function

Noise/heat insulation

Test tap with level tube

Two drain valves for recovering water/wash solution

Five-compartment injector for powder detergent

(located at the front or on the right hand side of the machine)

Third water valve

Large water valves

Integrated weighing system (IWS)

Connection for intelligent detergent system (DMIS)

Connection to CMIS

Main specifications

 

 

W4850H

Max. capacity

 

 

kg/lb

90/200

Drum,

volume

 

litre/ft3

850/30

 

diameter

 

ø mm/inch

1220 / 48 1/16

Extraction

 

 

rpm

720

G-factor

 

 

 

350

Heating alternatives

steam

 

x

 

 

non-heated

 

x

 

 

electricity

kW

Consumption data ”Normal 60°C” *

 

 

Total time (cold+hot/cold)

 

min

45/50

Water consumption (cold/hot)

 

litre

713/125

 

 

 

gallon

188/33

Energy consumption (motor/heating)

kWh

2.3/–

Steam consumption (cold/hot)

 

kg/lbs

10/22

Steam consumption (cold)

 

kg/lbs

19/41.9

* Water temperature 59°F cold water and 149°F hot water.

 

 

 

 

 

 

 

Certified in accordance with ISO 9001 and ISO 14001 and approved IP 24D. Certified in accordance with UL/ETL standards.

Electrical connections

Heating

Main voltage

 

Heating

Total

Recommended

alternative

 

 

power

power

fuse

 

 

Hz

kW

kW

A

Steam or

208-240V 3 ~

60

-

6.3

30

Non heated

400/480V 3 ~

60

-

6.3

15

Water, steam and air connections

 

W4850H

Water valves

inch

1 1/4

Rec. Water pressure

psi

30-90

Function limits for water valve

psi

10-145

Capacity at 300 kPa

l/min / gallon/min

150/37

Drain valve

ø mm/inch

110 / 4 5/6

Draining capacity

l/min / gallon/min

400/100

Steam valve

inch

1 1/4

Rec. Steam pressure

psi

7-40

Function limits for steam valve

psi

8-120

Compressed air

inch

1/8

Air pressure

psi

30-60

Air consumption

l/h / gallon/h

20/5

Five-compartment detergent injector

inch

3/4

 

 

 

Floor requirements

 

 

Frequency of the dynamic force

Hz

12.0

Floor load at max extraction

kN

25.9 ± 1.5

 

lbs force

5830 ± 340

 

 

 

Sound levels

 

 

Sound level

dB(A)

73

Sound level, with insulation

dB(A)

< 70

 

 

 

Heat emission

 

 

% of installed power, max 90°

 

6.7

 

 

 

Shipping data

 

 

 

net, kg/lbs

2200/4850

Shipping volume

m3/ft3

7.6/269