Identification:
Technical Bulletin no:
Date: Issuer:
Factory:
Subject Model
Problem Reason Action in Factory
ELECTROLUX PROFESSIONAL SPA MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIALE TREVISO, 15 33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIALE TREVISO, 15 33170 PORDENONE - ITALY
PDD2005-08 (page 1 of 10), 2nd
23 May 2005 Filippo Fingolo (Ovens Customer Support Dept.) PDD Vallenoncello - Italy

New regulations for AOS gas ovens

All AOS gas combi lenghtwise ovens Possibility of whistling noise during oven working Differences in LPG mixture From SN 513 introduced new gas regulations (see table) and
components, also alternative solutions (LPG1 and LPG2) for LPG installations:
for 6 gas combi ovens:
- new cavity burner (0C1082), replaced pieces In sparepart wharehouse for 10 1/1 and 20 1/1 gas combi ovens:
- new PWM parameters
- offset regulations with range of values
- new nozzle with diameter 5,50 for cavity burner (spare part code 0C2442) for LPG2/G30 installations
for 10 2/1 gas combi ovens:
- new PWM parameters
- offset regulations with range of values
for 20 2/1 gas combi ovens:
- new PWM parameters
- offset regulations with range of values
- new nozzles with diameter 7,50 (0C2444), 6,00 (0C2445), 5,80 (0C2446) for boiler burners
- new aerator (red one, 0C1045) for boiler burners
- new chimneys for boiler (0C2447)
- new burner for the boiler (0C2190), spare part updated with the new burner
- introduction of a circular mesh (0C2513) and a circular restriction (0C2514) on boiler’s
++39 0434 380528 www.electrolux.com 00072220932
++39 0434 380555 filippo.fingolo@electrolux.it
Action in Field
- Nozzles, chimneys, aerators, burner, meshes and restrictions available also in the kit 0C2515
See below the new calibrations and instructions for gas conversion
2

GAS CALIBRATIONS

AOS061G
CAVITY BURNER
GAS Injector Aerator
G20 6.50 Yellow - 0.20 35 30 60 G25 7.80 Yellow - 0.20 35 30 60 G30 5.30 Yellow - 0.25 40 28 43 LPG 5.30 Yellow - 0.13 40 28 43
BOILER BURNER
GAS Injector Aerator
OFFSET
(hPa)
Parameters
StcAhAcAFucA
OFFSET
(hPa)
Parameters
Stbo hAbo Fubo
G20 6.50 Yellow - 0.20 55 35 78 G25 7.80 Yellow - 0.20 55 35 78 G30 5.30 Yellow - 0.28 55 36 66 LPG 5.30 Yellow - 0.18 55 36 66