Electrolux IH21, IH24, IH 18 User Manual

0 (0)

Instantaneous

IH 18 electronic basic

Water Heater

IH 21 electronic basic

 

IH 24 electronic basic

 

 

Instructions for installation and use

Contents

Page

Important instructions for the user

3

General

3

Operating the appliance

3

Temperature preselection

3

Hot water flowrate

4

Care and maintenance of the appliance

4

Important instructions for the installer

5

General

5

Appliance constitution

5

Technical data

6

Appliance function

7

Safety temperature limiter

7

Installing the appliance

8

Dimensioned diagram

8

Appliance installation

9

Hood dismounting

9

Wall mounting

9

Water connection

10

Concealed installation

10

Installation versions

11

Cleaning the strainer insert

12

Flowrate limiter

12

Electrical connection

13

Mains connection

13/14

Circuit diagram

14

Temperature selector range limitation

15

Hood assembly

15

Using the appliance for the first time and checking

16

Fault-finding

17

Fault indications

18

Important for the expert

19

Customer service

20

2

Important instructions for the user

General

-Installation and startup should only ever be performed by an approved installer or authorised installation firm.

-Before using the appliance, please read through these instructions carefully. The manufacturer cannot accept any liability for damage resulting from failure to follow these instructions.

-Fittings and connecting pipes may get hot. Therefore keep children well away.

Operating the appliance

The ELECTROLUX IH electronic instantaneous water heater heats the water as the latter continuously flows through it. When the hot water tap is opened, the appliance switches on at a flowrate of around 3 l/min. When the hot water valve is closed or if the flowrate is reduced below 2.5 l/min, the appliance switches itself off again. The appliance is suitable for household use and should only ever be used for heating of drinking water.

One or more tapping points can be supplied with hot water.

Temperature preselection

The electronic system allows continuous temperature selection in the range from 30°C to 60°C.

Recommendation for energy-saving operation:

40°C for washbasin, shower, and bath (knob tangibly engages).

55°C for kitchen sink. If this temperature is no longer needed, the appliance should be reset to the 40°C energy-

saving level.

Wash basin

Shower

Bath basin

Kitchen sink

When the appliance is operated with a thermostatic mixer tap, the temperature setting on the instantaneous water heater must be around 8°C higher than on the thermostatic mixer tap.

3

Hot water flowrate

Up to the appliance’s max. power limit, the instantaneous water heater supplies the set hot water temperature regardless of the water flowrate selected.

If the hot water temperature is not attained when the hot water valve is fully opened, more water flows than can be heated by the appliance power. In this case, the hot water tap must be slightly closed.

Because of the different inlet temperatures, the hot water output varies depending on the season.

The following outlet flowrates for bath or shower water (40°C) or washbasin/ sink water (55°C) are attained at the inlet temperatures of 6°C, 10°C,

and 14°C.

Cold

Outlet temperature

Outlet temperature

water

 

40°C

 

 

55°C

 

tempe

 

 

 

 

 

 

 

 

 

 

 

 

rature

18 kW

21 kW

24 kW

18 kW

21 kW

24 kW

°C

 

 

 

 

 

 

 

l/min

l/min

l/min

l/min

l/min

l/min

 

 

 

 

 

 

 

6

7,6

8,8

10,1

5,3

6,1

7

 

 

 

 

 

 

 

10

8,6

10

11,5

5,7

6,7

7,6

(*8)

(*9)

(*10)

 

 

 

 

 

 

 

 

 

 

 

14

9,9

11,6

13,2

6,3

7,3

8,4

(*8)

(*9)

(*10)

 

 

 

 

 

 

 

 

 

 

 

(*) limited to this figure by the built-in flow limiter

Care and maintenance of the appliance

Clean the plastic housing as necessary with a damp cloth and dilute soap solution. Never use any abrasive, scouring, and solvent-containing detergents. The instantaneous water heater generally needs no maintenance. Regular inspection of the appliance by a trained engineer will ensure its operational reliability and prolong its service life.

Scale deposits in the outlet of fittings reduce the water flowrate. The air bubblers of the fittings or hand shower head must therefore be cleaned from time to time.

4

Electrolux IH21, IH24, IH 18 User Manual

Important instructions for the installer General

The instantaneous water heater is manufactured and tested in conformity with the valid IEC specifications and DIN standards. The appliance complies with the Appliance Safety Act. The indications given on the rating plate, the technical connection specifications of the electricity and water companies in the geographical area concerned, and VDE 0100 and DIN 1988 must be observed when the appliance is being installed.

The specific resistance of the water at the installation site should not be less than 1100 Ωcm.

This appliance complies with the following EC Directives:

-the ”Low-Voltage Directive” 72/23/EEC of 19.02.1973, including Amendment Directive 93/68/EEC

-the”Electromagnetic Compatibility” Directive 89/336/EEC of 03.05.1989 including Amendment Directive 92/31/EEC

Appliance constitution

12 3

 

4

14

5

 

 

6

4a

7

 

13

 

8

 

 

 

 

9

 

 

10

 

3a

11

12

 

1 =Back wall

2 =Quick fastener for appliance mounting

3 =Upper cable bushing

3a = Lower cable bushing

4 =Upper mains connection terminal (factory-prefitted)

5 =Flowrate sensor

6 =Safety temperature and pressure limiter

7 =Electronic module

8 =Temperature selector knob

9 =Flowrate limiter

10 =Strainer insert

11 = Cold water connection

12 =Hot water connection

13=Thermostat

14=Heating block

5

Technical data

Model

 

 

IH E

IH E

 

IH E

 

 

 

18 basis

21basis

 

24 basis

Type

 

 

 

unvented

 

 

 

 

 

 

 

 

Nominal capacity

 

l

 

0,4

 

 

 

 

 

 

 

 

 

Dimensions

 

mm

 

 

 

 

Width

 

 

 

226

 

 

Height

 

 

 

469

 

 

Depth

 

 

 

99

 

 

 

 

 

 

 

 

 

Weight

 

kg

 

3,9

 

 

 

 

 

 

 

 

 

Nominal overpressure

 

Mpa

 

 

 

 

 

 

 

 

 

 

 

Protection class to VDE

 

 

 

I

 

 

 

 

 

 

 

Protection type to VDE

 

 

IP 25 (splash-water protected)

 

 

 

 

 

 

Test mark

 

 

 

See rating plate

 

 

 

 

 

 

 

Water connection

 

 

 

G 1/2 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical connection

 

 

 

3 / PE ~ 380 V

 

 

 

 

 

 

 

 

Nominal output

 

kW

18

21

 

24

 

 

 

 

 

 

 

Spec. water resistance at

 

Ohm cm

 

> 1100

 

 

15 °C

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch-on flow pressure*)

 

Mpa

0,04

0,035

 

0,03

 

 

 

 

 

 

 

Switch-on flowrate

 

l/min

 

3

 

 

 

 

 

 

 

 

Mains retroactive effect

 

 

Free from any mains retroactive effect

 

 

 

to DIN EN 60555/VDE 0838

 

 

 

 

VDEW Approval

 

 

 

 

 

 

 

Maximum inlet

 

°C

 

25 °C

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flowrate limitation

 

l/min

8

9

 

10

 

 

 

 

 

 

 

*) In addition to the flow pressures of the instantaneous water heater itself, consideration must be given to the pressure losses in the household pipework.

6