Warewashing

PROJECT NAME # ______________________________________

 

66Single Tank Conveyor Dishwasher

SIS # _________________________________________________

 

with Built In Hot Water Booster WT66

AIA # _________________________________________________

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main features

 

 

 

 

 

 

 

 

• Built in hot water booster (top mounted in wash/rinse section).

 

 

 

 

• Water booster temperature rise can be set on site during the installation of the

 

 

 

 

machine. 40 °F rise (140 °F incoming water temperature), 70 °F rise (110 °F

 

 

 

 

incoming water temperature) or

 

 

 

 

100 °F rise (80 °F incoming water temperature).

 

 

 

 

• Atmospheric booster system with air break.

 

 

 

 

• Built in rinse booster pump guarantees constant rinse pressure.

 

 

 

 

• Speed of conveyor can be set through the control panel by the operator.

 

 

 

 

130 racks/hr or 200 racks/hr.

 

 

 

 

• Large counter balanced inspection doors in pre wash and wash/rinse sections

 

 

 

 

allow unrestricted all round access to the wash and rinse area. Door is insulated

 

 

 

 

with injected foam. This adds strength as well as reduces noise and heat loss.

 

 

 

 

• Large filters sloping towards the front to the smaller pressed filter box for quick

 

 

 

 

removal. Filters feature holes smaller than the concave ant-block wash nozzles so

 

Warewashing

 

 

large food cannot enter and block the wash system. Filters easy to remove from

 

 

 

pre wash as well as wash/rinse sections.

 

66Single Tank Conveyor Dishwasher

 

• Adjustable feet for full access underneath the machine for cleaning.

 

with Built In Hot Water Booster WT66

 

• Push button self cleaning cycle of the wash and rinse zones for ease of “end of

 

534090 (WT66BL208)

66″ Conveyor Dishwasher with

 

day” cleaning.

 

 

• Wash chamber without internal pipes and therefore no hidden dirt traps.

 

 

Built in Booster. Left to Right - 208V

 

 

 

 

• Pre wash chamber without internal pipes and therefore no hidden

 

534091 (WT66BR208)

66″ Conveyor Dishwasher with

 

 

 

dirt traps.

 

 

Built in Booster. Right to Left - 208V

 

 

 

 

• Self draining wash pumps provide maximum hygiene with no smells and all

 

534092 (WT66BL240)

66″ Conveyor Dishwasher with

 

 

 

wash and rinse zones drain automatically at the push of a button.

 

 

Built in Booster. Left to Right - 240V

 

 

 

 

• Powerful 0.5 HP pre-wash pump.

 

534093 (WT66BR240)

66″ Conveyor Dishwasher with

 

 

 

Built in Booster. Right to Left - 240V

 

• Powerful 2 HP wash pump.

 

 

 

 

• Heavy duty stainless steel wash pump (impeller and housing).

 

 

 

 

 

Short Form Specification

 

• Pre wash section uses cold water so food remains are not “baked” onto the

 

 

plates.

 

 

 

 

• Deep drawn pressed 26 gal wash tank with fully rounded corners, sloped

 

Item No. ___________________________________

 

towards the drain to prevent dirt build up provides fast drainage in only a few

 

 

minutes. Pressed wash tank with no welded points offer a guaranteed water

 

Unit to be Electrolux WT66 Hot Water Sanitizing 66″ single tank conveyor

 

tight solution.

 

 

• Deep drawn pressed 11.8 gal pre wash tank with fully rounded corners.

 

dishwasher with built in hot water booster. Electrical characteristics to be

 

 

____ 208 V or ____ 240 V three phase operation. Unit to operate from ___

 

• Dishwasher structure is held together with a solid 2″ × 2″ stainless steel tube

 

left to right or ____ right to left. Unit to feature atmospheric built in booster

 

sub-frame to provide long term sturdiness.

 

system with built in rinse booster pump thus guaranteeing rinse pressure

 

• All main components made in heavy duty anti-corrosive 304 type stainless steel:

 

during rinse cycle. Hot water booster temperature rise can be selected

 

 

 

tanks, panels, pre wash, wash & rinse arms and caps, doors, front, handle, rear

 

during installation from three options, 40 °F rise (140 °F incoming water

 

 

temperature), 70 °F rise (110 °F incoming water temperature) or 100 °F

 

and side-panels and rack transportation system.

 

rise (80 °F incoming water temperature). Unit to include 22″ pre-wash zone.

 

• Pre wash, wash and rinse arms can be easily removed for cleaning.

 

Pre-wash zone with powerful 0.5 hp cold water pre wash. Unit to have two

 

• IPX5 (NEMA4) water protection ensures no damage from cleaning.

 

conveyor speeds which can be selected from the control panel by the

 

 

 

• Autostart/stop ensures that the machine runs only when a rack is passing

 

operator, 130 racks/hour or 200 racks/hour. Maximum water consumption

 

 

at 200 racks/hour of only 83 gal/hour (0.4 gal/rack). Unit to feature large

 

through it. This reduces both water and energy consumption.

 

heat and noise insulated front counter balanced door in pre wash and

 

• Internal curtains made of silastic material and are not affected by detergent or

 

wash/rinse sections for easy access of internal components. Powerful 2

 

heat.

 

HP wash pump and specially designed wash spray arms to guarantee

 

• Electronic control panel features large display for reading of wash and rinse

 

cleaning. Unit to feature as standard end of day self cleaning cycle. Drain

 

 

 

temperatures.

 

of water from the machine can be done through the control panel. Large

 

 

deep drawn 26 gal wash tank for extended wash sessions.

 

• Low water consumption. At 200 racks per hour, the machine uses only

 

Covered by Electrolux Platinum Star® Service Program two-year parts

 

83 gal/hr (0.4 gal/rack).

 

and one-year labor warranty, installation start-up and performance check-

 

• Machine predisposed for external detergent and rinse aid connections.

 

up after one year from installation.

 

Included Accessories

 

 

 

 

 

 

 

 

 

 

 

 

• Vent cowls (left and right side).

 

 

 

 

• One open sided dishwasher rack for trays.

 

 

3048424

 

• Rack for cups.

 

 

 

• Rack for dinner plates.

Approval: ___________________________________________

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrolux Professional, Inc. www.electroluxusa.com/professional

3225 SW 42nd Street, Fort Lauderdale, Florida, 33312 • Telephone Number: 866-449-4200 • Fax Number: 954-327-6789

uiltB InHT66ot r

with Dishwasher Conveyor Tank Single 66

Warewashing

Electric

Supply voltage: 534090

208V/3ph/60Hz

534091 208V/3ph/60Hz

534092 240V/3ph/60Hz

534093 240V/3ph/60Hz

Dishwasher has three selectable hot water booster configurations according to inlet water supply temperature.

Dishwasher requires two separate electrical service connections. Connection 1 for Hot Water Booster; Connection 2 for running of the machine (wash pump, tank heat, conveyor drive motor, rinse booster pump, electronic control). Refer to the information below for Amp requirements.

Booster 40 °F rise Electrical Characteristics

Hot Water Booster Amp Load Connection 1:

208 V/3p/60Hz

33.35A (12 kW)

240 V/3p/60Hz

28.9A (12 kW)

Wash Pump, Tank heat Amp Load Connection 2:

208 V/3p/60Hz

64A (21 kW)

240 V/3p/60Hz

57.5A (21 kW)

Total Amp Load: 208 V/3p/60Hz

97.4A (33 kW)

240 V/3p/60Hz

86.4A (33 kW)

Booster 70 °F rise Electrical Characteristics

Hot Water Booster Amp Load Connection 1:

208 V/3p/60Hz

50A (18 kW)

240 V/3p/60Hz

43.3A (18 kW)

Wash Pump, Tank heat Amp Load Connection 2:

208 V/3p/60Hz

64A (21 kW)

240 V/3p/60Hz

57.5A (21 kW)

Total Amp Load: 208 V/3p/60Hz

114A (39 kW)

240 V/3p/60Hz

100.8A (39 kW)

Booster 100 °F rise Electrical Characteristics

Hot Water Booster Amp Load Connection 1:

208 V/3p/60Hz

66.6A (24 kW)

240 V/3p/60Hz

57.7A (24 kW)

Wash Pump, Tank heat Amp Load Connection 2:

208 V/3p/60Hz

64A (21 kW)

240 V/3p/60Hz

57.5A (21 kW)

Total Amp Load: 208 V/3p/60Hz

130.6A (45 kW)

240 V/3p/60Hz

115.2A (45 kW)

Warewashing

66Single Tank Conveyor Dishwasher

with Built In Hot Water Booster WT66

Water

Inlet Water supply pressure:

22 – 102 psi (150 – 700 kPa)

Inlet Cold Water Supply Temperature

 

for pre wash section:

39-59 °F (4-15 °C)

Inlet Hot Water Supply Temperature for wash/rinse section (booster size can be set on site during installation):

 

140 °F (60 °C)

 

with booster set as 40 °F rise.

 

110 °F (44 °C)

 

with booster set as 70 °F rise.

 

80 °F (27 °C)

 

with booster set as 100 °F rise.

Inlet Water supply hardness:

4 - 8 gpg (7-14 °fH) max

Incoming Cold Water line size

G 3/4″

(pre wash):

Incoming Hot Water line size

G 3/4″

(wash/rinse section):

Drain line size (pre wash section):

G 1-1/2″

Drain line size (wash/rinse section):

G 1-1/2″

Water consumption: Gallons/hr:

83.2 gal/hr (315 liters)

Water consumption/rack:

0.4 gal/rack (1.5 l/rack)

Pre wash temperature:

< 105 °F (<40 °C)

Pre wash tank size:

11.8 gal (45 liters)

Pre wash pump power:

0.5 hp (0,37 kW)

Pre wash pump water flow:

39 gal/min (150 l/min)

Wash temperature:

160 – 172 °F (71-78 °C)

Wash tank size:

26 gal (100 liters)

Wash pump power:

2 hp (1.5kW)

Wash pump water flow:

118.9 gal/min (450 l/min)

Rinse temperature:

180 – 194 °F (82-90 °C)

Rinse pump power:

0.4 hp (0.32 kW)

Rinse pump water flow:

1.32 gal/min (5 l/min)

Hot water booster capacity:

6.2 gal (24 liters)

Initial fill Hot Water requirements:

32.2 gal (124 liters)

Initial fill Cold Water requirements:

11.8 gal (45 liters)

Exhaust Requirements

Unit supplied as standard with extended vent hoods (can be removed during installation if not required). Exhaust extraction not more than 160 CFM

Refer to installation diagram for minimum exhaust hood installation height .

Key Information

Productivity racks per hour

200 racks / 3600 dishes

(max speed):

(average 18 dishes per rack)

Productivity racks per hour

130 racks / 2340 dishes

(min speed):

(average 18 dishes per rack)

Table to Table connection:

66″ (1676 mm)

Number of Tanks:

1

Height with door open:

83-7/16″ (2119 mm)

Charging hole size (width):

20-7/8″ (530 mm)

Charging hole size (height):

19-3/4″ (501 mm)

Net weight:

1012 lb (459 kg)

Shipping weight:

1210 lb (549 kg)

Shipping width:

74-7/16″ (1890 mm)

Shipping depth:

40-15/16″ (1040 mm)

Shipping height:

81-1/8″ (2060 mm)

Shipping volume:

143 cu.ft (4.05 m3)

Noise level:

<70 dBA

Unit predisposed to accept external detergent dispensers, detergent probes and rinse aid dispensers.