Dometic IB36H401RIY, IB36H401RI User Manual

0 (0)

AIR CONDITIONERS

IBIS 4

IB36H401RI, IB36H401RIY

EN

Air conditioning roof unit

Operating manual

 

IBIS 4

Original instructions

Please read this instruction manual carefully before first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it.

You find the installation manual online at: “dometic.com/manuals”.

The instructions in the installation manual are intended for qualified personnel at workshops who are familiar with the guidelines and safety precautions to be applied.

Table of contents

1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2.1 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2.2 Operating the device safely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3 Target group for this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

5 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 5.1 Control panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 5.2 Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 5.3 Air conditioning modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 5.4 Additional functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

6 Before initial use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

7 Operating the roof air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7.1 Basic notes on operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7.2 Using the remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 7.3 Hints for improved use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 7.4 Switching the roof air conditioner on and to stand-by . . . . . . . . . . . 14 7.5 Selecting the air conditioning mode . . . . . . . . . . . . . . . . . . . . . . . . . 14 7.6 Selecting the fan setting manually . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 7.7 Setting the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 7.8 Adjusting the air nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 7.9 Setting the time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

AU

3

 

 

 

Explanation of symbols

IBIS 4

 

7.10 Activating the sleep function . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . 17

 

7.11 Replacing the remote control batteries . . . . . . . . . . . . . . . . . . . . .

. . 17

 

7.12 Setting the timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . 18

8

Cleaning the roof air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . 19

9

Maintenance of the roof air conditioner . . . . . . . . . . . . . . . . . . . . . .

. . 21

10

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 22

11

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 24

12

Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 24

13

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 26

1Explanation of symbols

!WARNING!

Safety instruction: Failure to observe this instruction can cause death or serious injury.

!CAUTION!

Safety instruction: Failure to observe this instruction can lead to injury.

ANOTICE!

Failure to observe this instruction can cause material damage and impair the function of the product.

INOTE

Supplementary information for operating the product.

2Safety instructions

The manufacturer accepts no liability for damage in the following cases:

Damage to the product resulting from mechanical influences and incorrect connection voltage

Alterations to the product without express permission from the manufacturer

Use for purposes other than those described in the operating manual

4

AU

 

IBIS4

Safety instructions

In particular, the manufacturer will not be liable for any consequential damage, especially consequential damage caused by failure of the roof air conditioner.

2.1General safety

!WARNING!

Electrical devices are not toys.

The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are under supervision or have been given instruction.

Children should be supervised to ensure that they do not play with the appliance.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are under supervision or have been given instruction concerning use of the appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be performed by children without supervision.

Only use the device as intended.

Do not make any alterations or conversions to the device.

Installation, maintenance and repairs of the roof air conditioner may only be carried out by qualified personnel who are familiar with the risks involved when handling refrigerant and air conditioning systems as well as the relevant regulations. Inadequate repairs may cause serious hazards. For repair service, please contact the service centre in your country (addresses on the back page).

Do not use the device near flammable fluids or in closed rooms.

Make sure no combustible objects are stored or installed near the air outlet. A distance of at least 50 cm must be kept.

Do not reach into air outlets or insert any foreign objects in the roof air conditioner.

Do not undo the upper cover of the roof air conditioner in the event of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires.

AU

5

 

 

 

Target group for this manual

IBIS 4

ANOTICE!

Never drive through automatic car washes when the roof air conditioner is mounted.

Please ask your vehicle manufacturer if a technical inspection is required after fitting an air conditioner and whether the height entered in your vehicle documents needs to be altered.

If faults occur in the roof air conditioner's refrigerant circuit, the roof air conditioner must be checked by a specialist company and properly repaired. The refrigerant must never be released into the air.

2.2Operating the device safely

!WARNING!

Always disconnect the power supply when working on the device.

ANOTICE!

The roof air conditioner is not suitable for use in agricultural or construction vehicles.

Operate the device only if you are certain that the housing and the cables are undamaged.

3Target group for this manual

This operating manual is for the user of the roof air conditioner.

4Intended use

The Harrier Lite roof air conditioner is designed for installation on the roof of a caravan or recreational vehicle to provide reverse cycle heating and cooling. It is intended for vehicles with roofs with a thickness of 20 to 100 mm. The roof air onditioner must be installed so that it is within ±10° of the horizontal plane. It is not suitable for houses and apartments.

The roof air conditioner is not suitable for installation in construction machines, agricultural machines or similar equipment. It will not work properly if exposed to strong vibrations.

The function of the roof air conditioner is guaranteed for temperatures between –2 °C and 52 °C.

6

AU

 

IBIS4

Technical description

5Technical description

The roof air conditioner supplies the interior with cool or warm air which is without dust and dirt and can be dehumidified.

The roof air conditioner is operated with the remote control or via the control panel on the air conditioner.

INOTE

The roof air conditioner can lower the temperature within the vehicle to a certain level. The temperature depends on the type of vehicle, the ambient temperature and the cooling capacity of your roof air conditioner.

Below an outer temperature of 16 °C the roof air conditioner doesn’t cool anymore. In this case only use the air conditioning mode “Ventilation” ().

5.1Control panel

1

1

The control panel (1) is at the air outlet unit of the roof air conditioner.

AU

7

 

 

 

Dometic IB36H401RIY, IB36H401RI User Manual

Technical description

IBIS 4

2

AUTO

Control and display elements (fig. 2):

Symbol Explanation

Switches the roof air conditioner on or to stand-by mode.

+ button: Increases the currently displayed value.

button: Reduces the currently displayed value.

Activates the sleep function (chapter “Additional functions” on page 11).

Indicates the timer is set.

Displays the set temperature and indicates fan level when fan is adjusted.

Enables/disables automatic mode (chapter “Air conditioning modes” on page 10).

Enables/disables cooling mode (chapter “Air conditioning modes” on page 10).

Enables/disables heating mode (chapter “Air conditioning modes” on page 10).

Adjusts the fan speed between Low, Med or High – showing as 1, 2 or 3 on the air outlet unit display for a short time when changed.

Enables/disables ventilation mode (chapter “Air conditioning modes” on page 10). Circulates air without heating or cooling.

Enables/disables dehumidification mode (chapter “Air conditioning modes” on page 10).

8

AU

 

IBIS4

Technical description

5.2Remote control

All settings of the device (e. g. temperature settings, timer programming) are transmitted to the roof air conditioner by remote control.

3

1

TURBO

°C/°F

The following control and display elements are available on the remote control (fig. 3, page 9) :

No./Button Explanation

1Display

Displays the following:

Time

Selected room temperature (target value) in °C or °F

Actual room temperature

Air conditioning mode

Fan level

Symbols for active additional functions

Battery status

AU

9

 

 

 