SPECIFICATION CHART
Model No. |
FAC100-1 |
Horsepower |
1 |
SCFM @ 40 psig |
3.7 |
SCFM @ 90 psig |
2.7 |
Bore |
1 3/4" |
Stroke |
1 1/4" |
Voltage-Single Phase |
120 |
Minimum Branch Circuit Requirement |
15 AMPS |
*Fuse Type |
Quick Acting |
Amperage at Max Pressure |
10 |
*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses.
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use symbols to the right. Please read the manual and pay attention to these sections.
URGENT SAFETY INFORMATION - A HAZ- |
Information for preventing damage to |
ARD THAT WILL CAUSE SERIOUS INJURY |
equipment. |
OR LOSS OF LIFE. |
|
IMPORTANT SAFETY INFORMATION - A |
Information that you should pay special |
HAZARD THAT MIGHT CAUSE SERIOUS |
attention to. |
INJURY OR LOSS OF LIFE. |
|
DeVilbiss Air Power Company • 213 Industrial Dr. • Jackson, TN 38301-9615
MGP-FAC100-1 6/2/97
TABLE OF CONTENTS
|
Page |
|
Page |
SAFETYGUIDELINES . ......................... |
Cover Page |
Extension Cords ......................................... |
6 |
|
|
GroundingInstructions ................................ |
6-7 |
WARRANTYSTATEMENT ..................................... |
3 |
Air Hose ...................................................... |
7 |
WARNINGCHART ............................................... |
4-5 |
OPERATINGPROCEDURES ............................... |
7 |
GLOSSARY ......................................................... |
5 |
STORAGE ........................................................... |
8 |
DUTYCYCLE ...................................................... |
5 |
AIRCOMPRESSOR |
|
|
|
DIAGRAM AND PARTS LIST ................................ |
9 |
DESCRIPTIONOFOPERATION ........................... |
6 |
|
|
|
|
TROUBLESHOOTINGGUIDE .............................. |
10 |
INSTALLATIONANDBREAK-IN |
|
|
|
PROCEDURES ................................................. |
6-7 |
HOW TO ORDER REPAIR PARTS .......... |
Back Cover |
Location of Air Compressor ........................ |
6 |
|
|
2—ENG
LIMITED WARRANTY
ONE YEAR FROM DATE OF PURCHASE
All merchandise manufactured by DeVilbiss Air Power Company is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user). Products covered under this warranty include: air compressors, *air tools, accessories, service parts, pressure washers, and generators used in consumer applications (i.e., personal residential household usage only).
Air compressors, *air tools, accessories, service parts, pressure washers, and generators used in commercial applications (income producing) are covered by a 90 day warranty.
DeVilbiss Air Power will repair or replace, at DeVilbiss's option, products or components which have failed within the warranty period. Repair or replacement, and service calls on 60 and 80 gallon air compressors, will be handled by Authorized Warranty Service Centers and will be scheduled and serviced according to the normal work flow and business hours at the service center location, and depending on the availability of replacement parts.
All decisions of DeVilbiss Air Power Company with regard to this policy shall be final.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
RESPONSIBILITY OF ORIGINAL PURCHASER (Initial User):
Retain original cash register sales receipt as proof of purchase for warranty work.
Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s).
Deliver or ship the product to the nearest DeVilbiss Air Power Authorized Warranty Service Center. Freight costs, if any, must be paid by the purchaser.
Air compressors with 60 and 80 gallon tanks only will be inspected at the site of installation. Contact the nearest Authorized Warranty Service Center, that provides on-site service calls, for service call arrangement.
If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center, the purchaser should contact DeVilbiss Air Power Company.
THIS WARRANTY DOES NOT COVER:
Merchandise sold as reconditioned, floor models and/or display models. Any damaged or incomplete equipment sold "as is".
Merchandise used as "rental" equipment.
Merchandise that has become inoperative because of ordinary wear, misuse, freeze damage, use of improper chemicals, negligence, accident, improper and/or unauthorized repair or alterations including failure to operate the product in accordance with the instructions provided in the Owners Manual (s) supplied with the product. *Air Tools: O-Rings and driver blades are considered ordinary wear parts, therefore, they are warranted for a period of 45 days from the date of purchase.
An air compressor that pumps air more than 50% during a one hour period is considered misuse because the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.
Merchandise sold by DeVilbiss Air Power which has been manufactured by and identified as the product of another company. The product manufacturer's warranty will apply.
Repair and transportation costs of merchandise determined not to be defective.
Cost associated with assembly, required oil, adjustments or other installation and start-up cost.
ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
DeVilbiss Air Power Company
213 Industrial Drive • Jackson, TN 38301-9615 • Telephone: 1-800-888-2468 , Ext. 2 • FAX: 1-800-888-9036
Form: SP-100-E - 4/25/96
3—ENG
IMPORTANT SAFETY INSTRUCTIONS
• SAVE THESE INSTRUCTIONS •
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
|
|
|
|
HAZARD |
|
WHAT CAN HAPPEN |
|
HOW TO PREVENT IT |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
RISK OF BURSTING |
ATTACHMENTS |
& ACCESSORIES |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
EXCEEDING THE PRESSURE RATING OF AIR |
|
FOLLOW THE EQUIPMENT MANUFACTUR- |
||||||||
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
TOOLS, SPRAY GUNS, AIR OPERATED |
|
ERS RECOMMENDATION AND NEVER EX- |
||||||||
|
|
|
|
|
|
ACCESSORIES, |
TIRES |
AND OTHER |
|
CEED THE MAXIMUM ALLOWABLE PRES- |
||||||
|
|
|
|
|
|
INFLATABLES CAN CAUSE THEM TO EX- |
|
SURE RATING OF ATTACHMENTS. NEVER |
||||||||
|
|
|
|
|
|
PLODE OR FLY APART, AND COULD RESULT |
|
USE COMPRESSOR TO INFLATE SMALL |
||||||||
|
|
|
|
|
|
IN SERIOUS INJURY. |
|
|
LOW-PRESSURE OBJECTS SUCH AS |
|||||||
|
|
|
|
|
|
|
|
|
|
|
CHILDREN’S TOYS, FOOTBALLS, |
|
||||
|
|
|
|
|
|
USE OF UNAUTHORIZED |
REPLACEMENT |
|
BASKETBALLS. ETC. |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
HOSE IS PERMANENTLY ATTACHED TO |
|||||||||
|
|
|
|
|
|
AIR HOSE COULD PRODUCE EXCESSIVE |
|
THE COMPRESSOR AND SHOULD ONLY BE |
||||||||
|
|
|
|
|
|
SYSTEM PRESSURE AND CAUSE |
|
REPLACED |
BY |
AUTHORIZED |
SERVICE |
|||||
|
|
|
|
|
|
DAMAGES TO THE COMPRESSOR AND |
|
CENTER PERSONNEL USING |
CERTIFIED |
|||||||
|
|
|
|
|
|
HOSE FAILURE WHICH COULD RESULT IN |
|
REPLACEMENT PARTS. |
|
|
|
|||||
|
|
|
|
|
|
SERIOUS INJURY. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
RISK OF |
IT IS NORMAL FOR ELECTRICAL |
|
ALWAYS OPERATE THE COMPRESSOR IN A |
|||||||||
|
|
|
|
CONTACTS WITHIN THE MOTOR AND PRES- |
|
WELL VENTILATED AREA FREE OF COM- |
||||||||||
|
|
EXPLOSION OR FIRE |
|
|||||||||||||
|
|
SURE SWITCH TO SPARK. |
|
|
BUSTIBLE |
MATERIALS, |
GASOLINE |
OR |
||||||||
|
|
|
|
|
|
|
|
|
|
|
SOLVENT VAPORS. |
|
|
|
||
|
|
|
|
|
|
IF ELECTRICAL SPARKS FROM COMPRES- |
|
IF SPRAYING |
FLAMMABLE MATERIALS, |
|||||||
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
SOR COME INTO CONTACT WITH |
|
LOCATE COMPRESSOR AT LEAST 20 FEET |
||||||||
|
|
|
|
|
|
FLAMMABLE VAPORS, THEY MAY IGNITE, |
|
AWAY FROM SPRAY AREA. AN ADDITIONAL |
||||||||
|
|
|
|
|
|
CAUSING FIRE OR EXPLOSION. |
|
LENGTH OF HOSE MAY BE REQUIRED. |
|
|||||||
|
|
|
|
|
|
RESTRICTING ANY OF THE COMPRESSOR |
|
STORE FLAMMABLE MATERIALS IN A |
|
|||||||
|
|
|
|
|
|
VENTILATION OPENINGS WILL CAUSE SERI- |
|
SECURE LOCATION AWAY FROM COM- |
|
|||||||
|
|
|
|
|
|
OUS OVERHEATING AND COULD CAUSE |
|
PRESSOR. |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
FIRE. |
|
|
|
|
NEVER PLACE OBJECTS AGAINST OR ON |
|||||
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
UNATTENDED OPERATION OF THIS PROD- |
|
TOP OF COMPRESSOR. |
OPERATE COM- |
|||||||
|
|
|
|
|
|
UCT COULD RESULT IN PERSONAL INJURY |
|
PRESSOR IN AN OPEN AREA AT LEAST 12 |
||||||||
|
|
|
|
|
|
OR PROPERTY DAMAGE. |
|
|
INCHES AWAY |
FROM |
ANY |
WALL |
OR |
|||
|
|
|
|
|
|
|
|
|
|
|
OBSTRUCTION |
THAT |
WOULD |
RESTRICT |
||
|
|
|
|
|
|
|
|
|
|
|
THE FLOW OF FRESH AIR TO THE VENTILA- |
|||||
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
TION OPENINGS. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ALWAYS REMAIN IN ATTENDANCE WITH |
|||||
|
|
|
|
|
|
|
|
|
|
|
THE PRODUCT WHEN IT IS OPERATING. |
|||||
|
|
|
|
|
|
|
|
|
|
|
UNPLUG COMPRESSOR WHENEVER IS NOT |
|||||
|
|
|
|
|
|
|
|
|
|
|
BEING USED. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
RISK OF |
YOUR AIR COMPRESSOR IS POWERED BY |
|
NEVER OPERATE THE COMPRESSOR OUT- |
|||||||||
|
|
|
|
ELECTRICITY. |
LIKE ANY OTHER ELECTRI- |
|
DOORS WHEN IT IS RAINING OR IN WET |
|||||||||
|
|
ELECTRICAL SHOCK |
|
|||||||||||||
|
|
CALLY POWERED DEVICE, IF IT IS NOT USED |
|
CONDITIONS |
|
|
|
|
||||||||
|
|
|
|
|
|
PROPERLY IT MAY CAUSE ELECTRIC |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
SHOCK. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
REPAIRS ATTEMPTED BY |
UNQUALIFIED |
|
ANY ELECTRICAL WIRING OR REPAIRS |
|
||||||
|
|
|
|
|
|
PERSONNEL CAN RESULT IN SERIOUS |
|
REQUIRE ON THIS PRODUCT SHOULD BE |
||||||||
|
|
|
|
|
|
INJURY OR DEATH BY ELECTROCUTION. |
|
PERFORMED BY AUTHORIZED SERVICE |
||||||||
|
|
|
|
|
|
|
|
|
|
|
CENTER PERSONNEL. IN ACCORDANCE |
|
||||
|
|
|
|
|
|
|
|
|
|
|
WITH NATIONAL AND LOCAL ELECTRICAL |
|||||
|
|
|
|
|
|
ELECTRICAL |
GROUNDING: |
FAILURE TO |
|
CODES. |
|
|
|
|
|
|
|
|
|
|
|
|
|
MAKE CERTAIN THAT THE ELECTRICAL |
|||||||||
|
|
|
|
|
|
PROVIDE ADEQUATE GROUNDING TO THIS |
|
CIRCUIT TO WHICH THE COMPRESSOR IS |
||||||||
|
|
|
|
|
|
PRODUCT COULD RESULT IN SERIOUS |
|
CONNECTED PROVIDES PROPER ELECTRI- |
||||||||
|
|
|
|
|
|
INJURY OR DEATH FROM ELECTROCU- |
|
CAL GROUNDING, CORRECT VOLTAGE |
|
|||||||
|
|
|
|
|
|
TION. SEE GROUNDING INSTRUCTIONS. |
|
AND ADEQUATE FUSE PROTECTION. |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4—ENG