SPECIFICATION CHART

Model No.

FAC100-1

Horsepower

1

SCFM @ 40 psig

3.7

SCFM @ 90 psig

2.7

Bore

1 3/4"

Stroke

1 1/4"

Voltage-Single Phase

120

Minimum Branch Circuit Requirement

15 AMPS

*Fuse Type

Quick Acting

Amperage at Max Pressure

10

*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses.

SAFETY GUIDELINES - DEFINITIONS

This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use symbols to the right. Please read the manual and pay attention to these sections.

URGENT SAFETY INFORMATION - A HAZ-

Information for preventing damage to

ARD THAT WILL CAUSE SERIOUS INJURY

equipment.

OR LOSS OF LIFE.

 

IMPORTANT SAFETY INFORMATION - A

Information that you should pay special

HAZARD THAT MIGHT CAUSE SERIOUS

attention to.

INJURY OR LOSS OF LIFE.

 

DeVilbiss Air Power Company • 213 Industrial Dr. • Jackson, TN 38301-9615

MGP-FAC100-1 6/2/97

TABLE OF CONTENTS

 

Page

 

Page

SAFETYGUIDELINES . .........................

Cover Page

Extension Cords .........................................

6

 

 

GroundingInstructions ................................

6-7

WARRANTYSTATEMENT .....................................

3

Air Hose ......................................................

7

WARNINGCHART ...............................................

4-5

OPERATINGPROCEDURES ...............................

7

GLOSSARY .........................................................

5

STORAGE ...........................................................

8

DUTYCYCLE ......................................................

5

AIRCOMPRESSOR

 

 

 

DIAGRAM AND PARTS LIST ................................

9

DESCRIPTIONOFOPERATION ...........................

6

 

 

 

 

TROUBLESHOOTINGGUIDE ..............................

10

INSTALLATIONANDBREAK-IN

 

 

 

PROCEDURES .................................................

6-7

HOW TO ORDER REPAIR PARTS ..........

Back Cover

Location of Air Compressor ........................

6

 

 

2—ENG

DeVillbiss MGP-FAC100-1 User Manual

LIMITED WARRANTY

ONE YEAR FROM DATE OF PURCHASE

All merchandise manufactured by DeVilbiss Air Power Company is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user). Products covered under this warranty include: air compressors, *air tools, accessories, service parts, pressure washers, and generators used in consumer applications (i.e., personal residential household usage only).

Air compressors, *air tools, accessories, service parts, pressure washers, and generators used in commercial applications (income producing) are covered by a 90 day warranty.

DeVilbiss Air Power will repair or replace, at DeVilbiss's option, products or components which have failed within the warranty period. Repair or replacement, and service calls on 60 and 80 gallon air compressors, will be handled by Authorized Warranty Service Centers and will be scheduled and serviced according to the normal work flow and business hours at the service center location, and depending on the availability of replacement parts.

All decisions of DeVilbiss Air Power Company with regard to this policy shall be final.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

RESPONSIBILITY OF ORIGINAL PURCHASER (Initial User):

Retain original cash register sales receipt as proof of purchase for warranty work.

Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s).

Deliver or ship the product to the nearest DeVilbiss Air Power Authorized Warranty Service Center. Freight costs, if any, must be paid by the purchaser.

Air compressors with 60 and 80 gallon tanks only will be inspected at the site of installation. Contact the nearest Authorized Warranty Service Center, that provides on-site service calls, for service call arrangement.

If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center, the purchaser should contact DeVilbiss Air Power Company.

THIS WARRANTY DOES NOT COVER:

Merchandise sold as reconditioned, floor models and/or display models. Any damaged or incomplete equipment sold "as is".

Merchandise used as "rental" equipment.

Merchandise that has become inoperative because of ordinary wear, misuse, freeze damage, use of improper chemicals, negligence, accident, improper and/or unauthorized repair or alterations including failure to operate the product in accordance with the instructions provided in the Owners Manual (s) supplied with the product. *Air Tools: O-Rings and driver blades are considered ordinary wear parts, therefore, they are warranted for a period of 45 days from the date of purchase.

An air compressor that pumps air more than 50% during a one hour period is considered misuse because the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.

Merchandise sold by DeVilbiss Air Power which has been manufactured by and identified as the product of another company. The product manufacturer's warranty will apply.

Repair and transportation costs of merchandise determined not to be defective.

Cost associated with assembly, required oil, adjustments or other installation and start-up cost.

ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

DeVilbiss Air Power Company

213 Industrial Drive • Jackson, TN 38301-9615 • Telephone: 1-800-888-2468 , Ext. 2 • FAX: 1-800-888-9036

Form: SP-100-E - 4/25/96

3—ENG

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.

 

 

 

 

HAZARD

 

WHAT CAN HAPPEN

 

HOW TO PREVENT IT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK OF BURSTING

ATTACHMENTS

& ACCESSORIES

 

 

 

 

 

 

 

 

 

 

 

 

 

EXCEEDING THE PRESSURE RATING OF AIR

 

FOLLOW THE EQUIPMENT MANUFACTUR-

 

 

 

 

 

 

 

 

 

 

 

 

 

TOOLS, SPRAY GUNS, AIR OPERATED

 

ERS RECOMMENDATION AND NEVER EX-

 

 

 

 

 

 

ACCESSORIES,

TIRES

AND OTHER

 

CEED THE MAXIMUM ALLOWABLE PRES-

 

 

 

 

 

 

INFLATABLES CAN CAUSE THEM TO EX-

 

SURE RATING OF ATTACHMENTS. NEVER

 

 

 

 

 

 

PLODE OR FLY APART, AND COULD RESULT

 

USE COMPRESSOR TO INFLATE SMALL

 

 

 

 

 

 

IN SERIOUS INJURY.

 

 

LOW-PRESSURE OBJECTS SUCH AS

 

 

 

 

 

 

 

 

 

 

 

CHILDREN’S TOYS, FOOTBALLS,

 

 

 

 

 

 

 

USE OF UNAUTHORIZED

REPLACEMENT

 

BASKETBALLS. ETC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOSE IS PERMANENTLY ATTACHED TO

 

 

 

 

 

 

AIR HOSE COULD PRODUCE EXCESSIVE

 

THE COMPRESSOR AND SHOULD ONLY BE

 

 

 

 

 

 

SYSTEM PRESSURE AND CAUSE

 

REPLACED

BY

AUTHORIZED

SERVICE

 

 

 

 

 

 

DAMAGES TO THE COMPRESSOR AND

 

CENTER PERSONNEL USING

CERTIFIED

 

 

 

 

 

 

HOSE FAILURE WHICH COULD RESULT IN

 

REPLACEMENT PARTS.

 

 

 

 

 

 

 

 

 

SERIOUS INJURY.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK OF

IT IS NORMAL FOR ELECTRICAL

 

ALWAYS OPERATE THE COMPRESSOR IN A

 

 

 

 

CONTACTS WITHIN THE MOTOR AND PRES-

 

WELL VENTILATED AREA FREE OF COM-

 

 

EXPLOSION OR FIRE

 

 

 

SURE SWITCH TO SPARK.

 

 

BUSTIBLE

MATERIALS,

GASOLINE

OR

 

 

 

 

 

 

 

 

 

 

 

SOLVENT VAPORS.

 

 

 

 

 

 

 

 

 

IF ELECTRICAL SPARKS FROM COMPRES-

 

IF SPRAYING

FLAMMABLE MATERIALS,

 

 

 

 

 

 

 

 

 

 

 

 

 

SOR COME INTO CONTACT WITH

 

LOCATE COMPRESSOR AT LEAST 20 FEET

 

 

 

 

 

 

FLAMMABLE VAPORS, THEY MAY IGNITE,

 

AWAY FROM SPRAY AREA. AN ADDITIONAL

 

 

 

 

 

 

CAUSING FIRE OR EXPLOSION.

 

LENGTH OF HOSE MAY BE REQUIRED.

 

 

 

 

 

 

 

RESTRICTING ANY OF THE COMPRESSOR

 

STORE FLAMMABLE MATERIALS IN A

 

 

 

 

 

 

 

VENTILATION OPENINGS WILL CAUSE SERI-

 

SECURE LOCATION AWAY FROM COM-

 

 

 

 

 

 

 

OUS OVERHEATING AND COULD CAUSE

 

PRESSOR.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRE.

 

 

 

 

NEVER PLACE OBJECTS AGAINST OR ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNATTENDED OPERATION OF THIS PROD-

 

TOP OF COMPRESSOR.

OPERATE COM-

 

 

 

 

 

 

UCT COULD RESULT IN PERSONAL INJURY

 

PRESSOR IN AN OPEN AREA AT LEAST 12

 

 

 

 

 

 

OR PROPERTY DAMAGE.

 

 

INCHES AWAY

FROM

ANY

WALL

OR

 

 

 

 

 

 

 

 

 

 

 

OBSTRUCTION

THAT

WOULD

RESTRICT

 

 

 

 

 

 

 

 

 

 

 

THE FLOW OF FRESH AIR TO THE VENTILA-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TION OPENINGS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALWAYS REMAIN IN ATTENDANCE WITH

 

 

 

 

 

 

 

 

 

 

 

THE PRODUCT WHEN IT IS OPERATING.

 

 

 

 

 

 

 

 

 

 

 

UNPLUG COMPRESSOR WHENEVER IS NOT

 

 

 

 

 

 

 

 

 

 

 

BEING USED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK OF

YOUR AIR COMPRESSOR IS POWERED BY

 

NEVER OPERATE THE COMPRESSOR OUT-

 

 

 

 

ELECTRICITY.

LIKE ANY OTHER ELECTRI-

 

DOORS WHEN IT IS RAINING OR IN WET

 

 

ELECTRICAL SHOCK

 

 

 

CALLY POWERED DEVICE, IF IT IS NOT USED

 

CONDITIONS

 

 

 

 

 

 

 

 

 

 

PROPERLY IT MAY CAUSE ELECTRIC

 

 

 

 

 

 

 

 

 

 

 

 

 

SHOCK.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPAIRS ATTEMPTED BY

UNQUALIFIED

 

ANY ELECTRICAL WIRING OR REPAIRS

 

 

 

 

 

 

 

PERSONNEL CAN RESULT IN SERIOUS

 

REQUIRE ON THIS PRODUCT SHOULD BE

 

 

 

 

 

 

INJURY OR DEATH BY ELECTROCUTION.

 

PERFORMED BY AUTHORIZED SERVICE

 

 

 

 

 

 

 

 

 

 

 

CENTER PERSONNEL. IN ACCORDANCE

 

 

 

 

 

 

 

 

 

 

 

 

WITH NATIONAL AND LOCAL ELECTRICAL

 

 

 

 

 

 

ELECTRICAL

GROUNDING:

FAILURE TO

 

CODES.

 

 

 

 

 

 

 

 

 

 

 

 

MAKE CERTAIN THAT THE ELECTRICAL

 

 

 

 

 

 

PROVIDE ADEQUATE GROUNDING TO THIS

 

CIRCUIT TO WHICH THE COMPRESSOR IS

 

 

 

 

 

 

PRODUCT COULD RESULT IN SERIOUS

 

CONNECTED PROVIDES PROPER ELECTRI-

 

 

 

 

 

 

INJURY OR DEATH FROM ELECTROCU-

 

CAL GROUNDING, CORRECT VOLTAGE

 

 

 

 

 

 

 

TION. SEE GROUNDING INSTRUCTIONS.

 

AND ADEQUATE FUSE PROTECTION.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4—ENG