Desa CD32M-1-2, CD42M, CD36M-1-2 User Manual

r
r
CD32M(-1)(-2)
CD36M(-1)(-2)
CD42M
DIRECT VENT GAS FIREPLACE
INSTALLATION INSTRUCTIONS
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers.
This fireplace may be installed as an OEM installation in a manufactured (mobile) home and must be installed in accordance with the manufacturers instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States o the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This fireplace is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the fireplace.
WARNING: This Direct Vent gas fireplace is intended for use with natural or propane gas only (depending on the type of gas you
particular model is approved for), do not attempt to burn any solid fuels in this fireplace.
G
I
S
E
N
D
C
E
D
R
E
I
T
F
I
This fireplace is manufactured for Stylecrest Inc. under the Coleman brand name by DESA International Inc.
DESA INTERNATIONAL
2701 INDUSTRIAL DRIVE P/N 109194-01 P.O. BOX 90024 REV D BOWLING GREEN, KY 42101-9004 10/02
www.desatech.com
SAVE THIS BOOK
CONTENTS
1. INTRODUCTION ------------------------------------------------------------ PG. 2
2. SELECTING LOCATION ------------------------------------------------------------- PG. 2
3. MINIMUM CLEARANCES ------------------------------------------------------------- PG. 3
4. VENT PIPE AND TERM. CLEARANCES ------------------------------------------------------------- PG. 3-4
5. VENTING INSTRUCTIONS ------------------------------------------------------------- PG. 5
6. FRAMING ------------------------------------------------------------- PG. 6
7. GAS SUPPLY TESTING AND HOOK-UP ------------------------------------------------------------- PG. 7
8. PILOT ADJUSTMENT ------------------------------------------------------------- PG. 8
9. SPECIFICATION TABLE ------------------------------------------------------------- PG. 8
10. GLASS PANEL REMOVAL ------------------------------------------------------------- PG. 9
11. LOG INSTALLATION ------------------------------------------------------------- PG. 9
12. BURNER FLAME ADJUSTMENT ------------------------------------------------------------- PG. 10
13. WIRING DIAGRAM ------------------------------------------------------------- PG. 10
14. LIGHTING INSTRUCTIONS ------------------------------------------------------------- PG. 11
15. CONVERSION KIT ------------------------------------------------------------- PG. 12-13
16. TROUBLESHOOTING ------------------------------------------------------------- PG. 14
17. ILLUSTRATED PARTS BREAKDOWN ------------------------------------------------------------- PG. 15-16
18. ILLUSTRATED PARTS LIST ------------------------------------------------------------- PG. 17
19. ACCESSORY AND REPLACEMENT PARTS ------------------------------------------------------------- PG. 18
- 1 - For more information, visit www.desatech.com
r
d
n
N
p
r
d
Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any othe appliance.
Due to high temperatures, the appliance should be located out of traffic and away from furniture an draperies.
Do not place clothing or other flammable materials o or near the appliance.
EVER leave children unattended when a fire is
burning in the fireplace.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause injury,
roperty damage, or loss of life. Refer to this manual fo assistance or additional information. Consult a qualifie installer or local distributor.
CHECK LOCAL CODES BEFORE INSTALLING THIS FIREPLACE.
FOR YOUR SAFETY
FOR YOUR SAFETY
INTRODUCTION
Models CD32M series, CD36M series and CD42M are heat circulating gravity direct vent gas fireplaces with sealed combustion chamber. These fireplaces use millivolt gas control valve and millivolt ignition system.
These fireplaces are convertible with the standard setup as natural gas. Conversion may be performed by the O.E.M. mobile home builder or by a qualified service person on-site. If you are uncertain as to what gas your unit is equipped for, pleas check the rating plate located in the interior of the appliance opening or consult your mobile home supplier or your local distributor of DESA/Coleman products.
BEFORE BEGINNING THE INSTALLATION OF THE FIREPLACE, READ THESE INSTRUCTIONS THROUGH, COMPLETELY.
This DESA/Coleman fireplace and its components
are safe when installed according to this installation manual. Unless you use DESA/Coleman components, which has been designed and tested for the fireplace system, you may cause a fire hazard.
The DESA/Coleman warranty will be voided by and
DESA/Coleman disclaims any responsibility for the following actions:
-2 - For more information, visit www.desatech.com
a) Modification of the fireplace, components, doors, blower, fans, air inlet system and damper control. b) Use of any component part not manufactured or approved by DESA/Coleman in combination with a DESA/Coleman fireplace system.
PROPER INSTALLATION is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces. This fireplace, when installed, must be electrically grounded in accordance with local codes, or in absence of local codes, with the National Electrical Code ANSI/NFPA 70 and CSA C22.2 Canadian electrical code for Canada. The installation must conform to local codes, or in the absence of local codes, with the national Fuel Gas Code ANSI Z223.1 – current installation code CAN/CGA-B149. This appliance complies with ANS Z21.88-2000/CSA 2.22-2000 VENTED GAS FIREPLACE HEATERS.
SELECTING LOCATION
To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines:
The location must allow for proper clearances (see
figure 1).
Consider a location were the fireplace would not be
affected by drafts, air conditioning ducts, windows or doors.
A location that avoids the cutting of joists or roof
rafters will make installation easier.
Figure 1 COMMON FIREPLACE LOCATIONS
Flush installation limited. Projected installation existing finished wall. Corner installation normally be used and provides a wider and more efficient range for radiant heat transfer.
is recommended where living space is
may be ideal for a new addition on an
makes use of a space that may not
In selecting a location, the following precautions must be
g
h
t
observed:
Do not connect this appliance to a chimney system
used for solid fuel burning fireplace.
Due to high temperatures, do not locate this appliance
in high traffic areas or near furniture and draperies.
Never obstruct the front opening of the appliance or
the flow of combustion and ventilation air. Keep control compartments accessible.
Do not locate close to where gasoline or other
WARNING: Do not block required air space wit insulation or any other material. Do not obstruc effective opening of appliance with any type of facing material.
VENT TERMINATION CLEARANCES
The final position of your fireplace depends on the location of the vent termination in relation to the clearances that must be
observed as shown in figures 3 and 4. flammable liquids may be stored. The appliance area must be kept clear and free from these combustible materials.
Do not use this appliance if any part has been under
water. Immediately contact a local service technician to examine the fireplace and to replace any part of the control ignition system and other related components that has been submerged under water.
MINIMUM CLEARANCES TO COMBUSTIBLES
Back and side of fireplace ------------------- 0”
Floor ------------------------------------------ 0”
Perpendicular wall --------------------------- 6”
Front ------------------------------------------- 36”
Top of Standoffs ----------------------------- 0”
MANTEL CLEARANCES
Woodwork, such as wood trims, mantels and other combustible materials should be placed within the required
Figure 3 VENT CLEARANCES
clearance specified on figure 2.
Ref. Mantel Depth Ref. Mantel from top
114"A16" 212"B14" 310"C12" 48"D10" 56"E8" 64"F6" 72"G4"
of opening
Fi
ure 2 MANTEL CLEARANCES
Figure 4 VENT CLEARANCES
-3 - For more information, visit www.desatech.com
VENT PIPE AND TERMINATION CLEARANCES
The final position of your appliance depends on the location of the termination in relation to the clearances that must be observed.
A= 12” (305mm) clearance above grade, veranda, porch, deck or balcony. *** B= 9” (229mm) clearance in U.S. and 12” (305mm) clearance in Canada to window or door that may be closed. C= 9” (229mm) clearance in U.S. and 12” (305mm) clearance in Canada to permanently closed window or door that maybe opened. D= 18” (475mm) vertical clearance to ventilated and 12” (305mm) to unventilated soffit located above the terminal within a horizontal distance of 2 feet (610mm) from the centerline of the terminal. E= 12” (305mm) clearance below eaves. F= 9” (229mm) clearance to outside corner.
G= 6” (15mm) clearance to inside corner.
H= not to be installed above a meter/regulator within 3 feet
(914mm) horizontally from the centerline of the regulator. ***
I= 36” (914mm) clearance in U.S. and 72” (1829mm) in
Canada to service regulator vent outlet. ***
J= 12” (305mm) clearance to non-mechanical air supply inlet
to building or the combustion air inlet to any other
appliance.***
K= 36” (914mm) clearance to a mechanical air supply inlet.
L= 84” (2134mm) clearance above paved sidewalk or paved
driveway located on public property. *
M= 12” (305mm) clearance under veranda, veranda, porch,
deck or balcony. **
* vent shall not terminate directly above a sidewalk or paved driveway that is located between two single-family dwellings and serves
both dwellings.
** only permitted if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.
*** as specified in CGA-B149 installation codes (1991) for Canada or for U.S. installation follow the current National Gas Code,
ANS Z223.1. Note: Local codes or regulations may require different clearances
.
-4 - For more information, visit www.desatech.com
VENT INSTALLATION INSTRUCTIONS
1. Install pipe to fireplace collar adapter located on back of unit at a 45 deg. Angle. Connect our starting pipe to a 45 deg. Starting section by sliding it over the collar adapter on the fireplace. Twist-lock for proper installation check to insure proper connection (see figure 5).
Figure 5 VENT INSTALLATION
2. Once the elbow is properly fastened to the fireplace adapter, continue to install the remainder of the pipe for the desired installation.
3. Install every section of the pipe making sure that all joints are properly twist-locked.
4. After steps 1, 2 and 3 are completed, install the vent termination. Depending on location of termination, you may use a vertical or horizontal termination.
5. Depending on the wall thickness, allow one inch to protrude from internal wall as shown in figure 6.
6. For vertical venting application, install vertical flue restrictor into inner collar of fireplace as shown in figure 5.
Figure 6 VENT TERMINATION
7. An optional siding standoff may be installed between the vent cap exterior wall. Secure horizontal top to standoff and then secure the complete assembly to wall (see figure 6). The vent termination must be removable for service pipe inspection.
The vent system serves as the “chimney” as well as the combustion air supply (air intake). The horizontal run must have a rise of ¼” (6 mm) for every 1 foot (305 mm) of horizontal run towards the termination. Never allow the vent to run downward. The maximum horizontal run depends on the vertical rise from fireplace adapter collar to the vent termination (see table below).
VERTICAL HORIZONTAL
ft mm ft mm
0to1'305 1 305 to 4 1219 2 610 to 8 2438 3 914 to 12 3658 41219to164877 51524to154572 61829to144267 72134to133962 82438to123658
WARNING: Vent pipe air space clearances to combustibles are 1” on all sides except on the horizontal sections, which require 2” clearances from the top of the pipe. Where the termination cap penetrates a combustible wall, 1” air space clearance is required.
When installing length of pipe over 3 ft. (914 mm) horizontally, support the pipe every 3 ft. (914 mm) using metal straps. Vertical to horizontal pipe must be kept at a one foot (305 mm) to 4 ft. (1219 mm) ratio with a maximum run of no more than 20 ft. If an offset is necessary in the attic to avoid obstruction, it is important to support the vent pipe every 3 ft. (914 mm), to avoid excessive stress on the elbows and possible separation see figure 7).
Figure 7 OFFSET ELBOW
-5 - For more information, visit www.desatech.com