Desa 5511 User Manual

0 (0)

®

Compact 150 Watt

Motion Sensing Halogen

Model 5511

The Motion Sensor Quartz Security Light turns on 150 watts of quartz-halogen lighting when motion is detected and then, after a selectable period of time, automatically turns the lighting off. The built-in photocell keeps the lighting off during daylight hours.

This package includes:

Cover Plate

Cover Plate

Gasket

 

 

4 Screws

 

 

(2 sizes)

Sensor

 

Halogen

 

Bulb

 

 

 

Light Fixture

3 Wire

 

 

 

 

Connectors

Requirements

The Light Control requires 120-volts AC. Do not connect through a dimmer or other electronic switch.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

The backplate has knockouts so the sensor can be mounted on most junction boxes.

In some applications a universal adaptor plate may be needed. Adaptors are available at Home Centers and Electrical Supply Stores.

© 2007 DESA Specialty Products™

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

 

x

Manual

Until Dawn*

 

x

* resets to Auto Mode at dawn.

Note: When fi rst turned on wait about 11/2 minutes for the circuitry to calibrate.

TEST

ON-TIME

Put the ON-TIME switch on the bottom of the sensor in the TEST position.

10 5 1 TEST

AUTO

ON-TIME

Put the ON-TIME switch in the 1, 5, or 10 minute position.

10 5 1 TEST

MANUAL MODE

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

... back on.

Mode Switching Summary

 

TEST

 

 

Move ON-TIME Switch

 

 

 

 

 

 

 

 

 

 

 

to 1, 5, or 10 minutes

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

Flip switch off for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

one second then

 

 

 

 

 

 

 

back on*

MANUAL MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time (11/2 min.) the control will be in the AUTO mode.

598-1310-00

Desa 5511 User Manual

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

For best performance, locate the fixture about 8 ft. (2.4 m) above the ground.

CAUTION: The sensor must be mounted below the lamp housing for wall installations.

Drill out the holes if needed to mount the backplate to the junction box.

CAUTION to avoid fire or burn hazards:

Allow fi xture to cool before touching. The bulb and fi xture operate at high temperatures.

Keep fi xture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).

Re-lamp with type T 150W (or less) halogen 120 VAC lamp only.

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

Rotate the sensor head to-

wards the clamp screw joint.

Controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clamp Screw

Then rotate the sensor head counterclockwise

180° so the controls face down.

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

BULB INSTALLATION AND RELAMPING

When relamping, turn power off and let the fi xture cool.

Remove the screw that holds the glass cover shut. Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.

To insert the new bulb, push the bulb into the right socket so the bulb fi ts completely into the left socket.

Check that the bulb is seated properly.

Close the glass cover. Replace screw.

WIRE THE LIGHT CONTROL

WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fi xture.

Strip about 5/8" insulation from the existing junction box wiring.

Route the Light Control’s wires through the large hole in the gasket.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

 

 

White to White

Black to Black

 

 

 

 

Junction box ground wire to green ground wire on fixture. Cover Plate

Gasket

MOUNT THE LIGHT CONTROL

Align the Light Control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws.

If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone weather sealant.

RIGHT

 

WRONG

 

The halogen light must be mounted horizontally (+/- 4°).

2

598-1310-00

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor requires about 1 1/2 minutes to calibrate before it will detect motion. When fi rst turned on, wait about 1 1/2 minutes.

Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.

ON-TIME

 

 

 

 

 

 

 

SENS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIN MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects refl ecting light may trigger the shut-off feature. Do not point other lights at the sensor.

110°

8 ft.

(2.4 m)

60 ft.

(18.3 m)

Maximum Range

Maximum

 

Coverage Angle

The control is most sensitive to motion across it.

Motion

Motion

 

Sensor

Least Sensitive

Most Sensitive

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor to aim.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area.Keep the sensor at least 1" (25 mm) away from the lamps.

Set SENSITIVITY as needed. Too much sensitivity may increase false triggering.

Secure the sensor head into position by tightening the clamp screw. Do not overtighten the screw.

Clamp

Ball

Joint

Aim Sensor Down for Short Coverage

Aim Sensor Higher for Long Coverage

Set the amount of TIME the lights stay on after motion is

detected. It is selectable from 1, 5, or 10 minutes.

SPECIFICATIONS

Range . . . . . . . . . . . . . Upto60ft.(18.3m);[varieswith surrounding temperature]

Sensing Angle . . . . . . . Up to 110°

Electrical Load. . . . . . . Up to 150 Watts Maximum tungsten

Power Requirements . . 120 VAC, 60 Hz

Operating Modes . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . 1, 5, or 10 minutes Sensitivity . . . . . . . . . . Adjustable

Replacement lamp. . . . T 150W (or less) halogen 120 VAC

DESA Specialty Products reserves the right to discontinue products and to change specifi cations at any time without incurring any obligation to incorporate new features in products previously sold.

598-1310-00

3