Compact 150 Watt
Motion Sensing Halogen
Model 5511
The Motion Sensor Quartz Security Light turns on 150 watts of quartz-halogen lighting when motion is detected and then, after a selectable period of time, automatically turns the lighting off. The built-in photocell keeps the lighting off during daylight hours.
This package includes:
Cover Plate
Cover Plate
Gasket
|
|
4 Screws |
|
|
(2 sizes) |
Sensor |
|
Halogen |
|
Bulb |
|
|
|
|
|
Light Fixture |
3 Wire |
|
|
|
|
|
Connectors |
Requirements
•The Light Control requires 120-volts AC. Do not connect through a dimmer or other electronic switch.
•If you want to use Manual Mode, the control must be wired through a switch.
•Some codes require installation by a qualified electrician.
•This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
•The backplate has knockouts so the sensor can be mounted on most junction boxes.
•In some applications a universal adaptor plate may be needed. Adaptors are available at Home Centers and Electrical Supply Stores.
© 2007 DESA Specialty Products™
OPERATION
Mode: |
On-Time |
Works: Day |
Night |
Test |
5 Seconds |
x |
x |
Auto |
1, 5, or 10 Min |
|
x |
Manual |
Until Dawn* |
|
x |
* resets to Auto Mode at dawn.
Note: When fi rst turned on wait about 11/2 minutes for the circuitry to calibrate.
TEST
ON-TIME
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
10 5 1 TEST
AUTO
ON-TIME
Put the ON-TIME switch in the 1, 5, or 10 minute position.
10 5 1 TEST
MANUAL MODE
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
1 Second OFF
then...
... back on.
Mode Switching Summary
|
TEST |
|
|
Move ON-TIME Switch |
|||
|
|
|
|
|
|||
|
|
|
|
|
|
to 1, 5, or 10 minutes |
|
|
|
|
|
|
|
|
|
|
AUTO |
|
|
|
|
Flip switch off for |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
one second then |
|
|
|
|
|
|
|
back on* |
MANUAL MODE |
|
|
|
||||
|
|
|
|
||||
|
|
|
|
|
|
|
|
*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time (11/2 min.) the control will be in the AUTO mode.
598-1310-00
INSTALLATION
For easy installation, select an existing light with a wall switch for replacement.
For best performance, locate the fixture about 8 ft. (2.4 m) above the ground.
CAUTION: The sensor must be mounted below the lamp housing for wall installations.
Drill out the holes if needed to mount the backplate to the junction box.
CAUTION to avoid fire or burn hazards:
•Allow fi xture to cool before touching. The bulb and fi xture operate at high temperatures.
•Keep fi xture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).
•Re-lamp with type T 150W (or less) halogen 120 VAC lamp only.
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.
Rotate the sensor head to-
wards the clamp screw joint. |
Controls |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Clamp Screw
Then rotate the sensor head counterclockwise
180° so the controls face down.
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
BULB INSTALLATION AND RELAMPING
When relamping, turn power off and let the fi xture cool.
Remove the screw that holds the glass cover shut. Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.
To insert the new bulb, push the bulb into the right socket so the bulb fi ts completely into the left socket.
Check that the bulb is seated properly.
Close the glass cover. Replace screw.
WIRE THE LIGHT CONTROL
WARNING: Turn power off at circuit breaker or fuse.
Remove the existing light fi xture.
Strip about 5/8" insulation from the existing junction box wiring.
Route the Light Control’s wires through the large hole in the gasket.
Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.
|
|
White to White |
Black to Black |
|
|
|
|
|
Junction box ground wire to green ground wire on fixture. Cover Plate
Gasket
MOUNT THE LIGHT CONTROL
Align the Light Control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws.
If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone weather sealant.
RIGHT |
|
WRONG |
|
The halogen light must be mounted horizontally (+/- 4°).
2 |
598-1310-00 |
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor requires about 1 1/2 minutes to calibrate before it will detect motion. When fi rst turned on, wait about 1 1/2 minutes.
Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.
ON-TIME |
|
|
|
|
|
|
|
SENS |
||||||
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MIN MAX |
||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|||
10 5 1 TEST |
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Bottom of Sensor
Avoid aiming the control at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large, light-colored objects refl ecting light may trigger the shut-off feature. Do not point other lights at the sensor.
110°
8 ft.
(2.4 m)
60 ft.
(18.3 m)
Maximum Range |
Maximum |
|
Coverage Angle |
The control is most sensitive to motion across it.
Motion |
Motion |
|
Sensor |
Least Sensitive |
Most Sensitive |
Loosen the clamp screw in the sensor ball joint and gently rotate the sensor to aim.
Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area.Keep the sensor at least 1" (25 mm) away from the lamps.
Set SENSITIVITY as needed. Too much sensitivity may increase false triggering.
Secure the sensor head into position by tightening the clamp screw. Do not overtighten the screw.
Clamp |
Ball
Joint
Aim Sensor Down for Short Coverage
Aim Sensor Higher for Long Coverage
Set the amount of TIME the lights stay on after motion is
detected. It is selectable from 1, 5, or 10 minutes.
SPECIFICATIONS
Range . . . . . . . . . . . . . Upto60ft.(18.3m);[varieswith surrounding temperature]
Sensing Angle . . . . . . . Up to 110°
Electrical Load. . . . . . . Up to 150 Watts Maximum tungsten
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 1, 5, or 10 minutes Sensitivity . . . . . . . . . . Adjustable
Replacement lamp. . . . T 150W (or less) halogen 120 VAC
DESA Specialty Products reserves the right to discontinue products and to change specifi cations at any time without incurring any obligation to incorporate new features in products previously sold.
598-1310-00 |
3 |