Dell E08J User Manual

0 (0)

Dell PowerVault MD3860f Storage Arrays

Owner's Manual

Regulatory Model: E08J Series

Regulatory Type: E08J001

Notes, Cautions, and Warnings

NOTE: A NOTE indicates important information that helps you make better use of your computer.

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Delland the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.

2015 - 02

Rev. A01

Contents

 

1 About your system................................................................................................

6

Introduction...........................................................................................................................................

6

Dell PowerVault Modular Disk Storage Manager ................................................................................

6

Related Documentation........................................................................................................................

6

Front-Panel Features ............................................................................................................................

7

Front-Panel Indicators .........................................................................................................................

8

Back-Panel Features............................................................................................................................

10

Cooling Fan Module LED Indicator Codes.........................................................................................

11

Power Supply Module Features And Indicators ................................................................................

12

Physical-Disk LED Indicators...............................................................................................................

13

2 Controller Modules.............................................................................................

15

RAID Controller Modules....................................................................................................................

15

MD3860f Fibre Channel RAID Controller Module Features And Indicators.....................................

15

Host Channel LED Link Rate Indications......................................................................................

16

SFP+ Transceivers Fibre Optic And SAS Cables............................................................................

17

Expansion Controller Modules............................................................................................................

18

MD3060e Expansion Module Features And Indicators................................................................

18

RAID Controller Module—Additional Features...................................................................................

19

Battery Backup Unit.......................................................................................................................

19

Storage Array Thermal Shutdown.......................................................................................................

19

System Password Reset......................................................................................................................

20

3 Installing and removing system components...............................................

21

Recommended Tools..........................................................................................................................

21

Removing And Installing The Front Bezel...........................................................................................

21

Installing The Front Bezel..............................................................................................................

21

Removing The Front Bezel............................................................................................................

22

Service Action Allowed Indicator LED................................................................................................

22

Physical-Disk Drawers........................................................................................................................

22

Opening The Physical-Disk Drawer..............................................................................................

23

Closing The Physical-Disk Drawer...............................................................................................

24

Removing The Physical-Disk Drawer...........................................................................................

24

Installing The Physical-Disk Drawer.............................................................................................

26

Physical Disks.......................................................................................................................................

27

Physical Disk Installation Guidelines.............................................................................................

27

Removing A Physical Disk From A Physical-Disk Carrier.............................................................

27

Installing A Physical Disk In A Physical-Disk Carrier....................................................................

29

Removing A Physical Disk From A Physical-Disk Drawer............................................................

30

Installing A Physical Disk In A Physical-Disk Drawer....................................................................

31

SAS Chain Cables.................................................................................................................................

31

Removing The SAS Chain Cable(s)...............................................................................................

32

Installing The SAS Chain Cable(s).................................................................................................

33

RAID Controller Modules....................................................................................................................

34

Removing A RAID Controller Module Or Expansion Module......................................................

34

Installing A RAID Controller Module Or Expansion Module........................................................

35

Opening The RAID Controller Module.........................................................................................

36

Closing The RAID Controller Module...........................................................................................

36

Replacing The SFP+ Transceiver........................................................................................................

37

RAID Controller Module Backup Battery Unit....................................................................................

38

Removing The RAID Controller Module Backup Battery Unit.....................................................

38

Installing The RAID Controller Module Backup Battery Unit.......................................................

39

Power Supplies....................................................................................................................................

39

Removing A Power Supply Module..............................................................................................

39

Installing A Power Supply Module................................................................................................

40

Cooling Fan Modules..........................................................................................................................

41

Removing A Cooling Fan Module.................................................................................................

41

Installing A Cooling Fan Module...................................................................................................

42

4 Troubleshooting your system..........................................................................

43

Safety first—for you and your system.................................................................................................

43

Troubleshooting Storage Array Startup Failure..................................................................................

43

Troubleshooting Loss Of Communication........................................................................................

43

Troubleshooting An SFP+ Transceiver...............................................................................................

43

Troubleshooting External Connections.............................................................................................

45

Troubleshooting Power Supply Modules...........................................................................................

45

Troubleshooting Array Cooling Problems.........................................................................................

46

Troubleshooting Expansion Enclosure Management Modules........................................................

46

If The EMM Status LED Is Solid Or Blinking Amber (2 Or 4 Times Per Sequence).....................

46

If The Link Status LEDs Are Not Green.........................................................................................

47

Troubleshooting RAID Controller Modules........................................................................................

47

If Both LEDs For Any Given FC IN Port Are Unlit..........................................................................

47

Troubleshooting Physical Disks..........................................................................................................

47

Troubleshooting Array And Expansion Enclosure Connections.......................................................

48

Troubleshooting A Wet Storage Array...............................................................................................

48

Troubleshooting A Damaged Array....................................................................................................

49

Controller Failure Conditions.............................................................................................................

49

Critical Conditions........................................................................................................................

49

Noncritical Conditions..................................................................................................................

49

Invalid Storage Array.....................................................................................................................

50

ECC Errors.....................................................................................................................................

50

PCI Errors.......................................................................................................................................

50

5 Technical Specifications....................................................................................

51

6 Getting help.........................................................................................................

55

Locating your system service tag.......................................................................................................

55

Contacting Dell...................................................................................................................................

55

Documentation feedback...................................................................................................................

55

1

About your system

Introduction

CAUTION: See the Safety, Environmental, and Regulatory Information document for important safety information before following any procedures listed in this document.

The Dell PowerVault MD3860f RAID storage array (16 Gbps Fibre Channel) is a 4U rack-mounted system, capable of accommodating up to sixty 3.5 inch or 2.5 inch physical disks. You can expand the number of physical disks up to a maximum of 120 disks (180 disks with premium feature kit), by daisy-chaining your storage enclosure with up to two MD3060e SAS based expansion enclosures.

NOTE: Your Dell MD Series Dense storage array supports two expansion enclosures (180 physical disks) after you install the Additional Physical Disk Support Premium Feature. To order the Additional Physical Disk Support Premium Feature key, got to dell.com/support.

This document familiarizes you with the functions of the Dell PowerVault MD Series storage array. The document is organized according to the tasks that you must complete after receiving your storage array.

Dell PowerVault Modular Disk Storage Manager

Dell PowerVault Modular Disk Storage Manager (MD Storage Manager) is a graphical user interface (GUI) application used to configure and manage one or more MD Series storage arrays. The MD Storage Manager software is located on the MD Series resource DVD.

Related Documentation

WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document.

NOTE: For all PowerVault documentation, go to dell.com/powervaultmanuals and enter the system Service Tag to get your system documentation.

NOTE: For all Dell OpenManage documents, go to dell.com/openmanagemanuals.

NOTE: For all storage controller documents, go to dell.com/storagecontrollermanuals.

Dell PowerVault MD3460/3860i/3860f Series Storage Arrays Getting Started Guide — Provides an overview of system features, setting up your system, and technical specifications. This document is also shipped with your system.

Dell PowerVault MD3860f Series Storage Arrays Owner’s Manual — Provides information about system features and describes how to troubleshoot the system and install or replace system components.

Rack Installation Instructions — Describes how to install your system into a rack. This document is also shipped with your rack solution.

6

Dell PowerVault MD Series Storage Arrays Administrator's Guide — Provides information about configuring and managing the system using the MDSM GUI.

Dell PowerVault MD Series Storage Arrays CLI Guide — Provides information about configuring and managing the system using the MDSM CLI.

Dell PowerVault MD3860f Series Storage Arrays Deployment Guide — Provides information about deploying the storage system in the SAN architecture.

Dell PowerVault MD 34xx and 38xx Series Support Matrix — Provides information about the software and hardware compatibility matrices for the storage array.

For the full name of an abbreviation or acronym used in this document, see the Glossary at dell.com/ support/manuals.

For Online Help Resource, navigate to dell.com/PVResources.

NOTE: For the latest documentation updates, check dell.com/support/manuals.

NOTE: When upgrading your system, it is recommended that you download and install the latest BIOS, driver, and systems management firmware on your system from dell.com/support.

Front-Panel Features

Figure 1. Front-Panel Features

 

 

1.

drawer (5)

2.

drawer release latch (2 per drawer)

3.

physical disk slot numbering

4.

drawer indicator LEDs

5.front-panel indicators

7

Dell E08J User Manual

Front-Panel Indicators

Figure 2. Front-Bezel Indicators

Figure 3. Front-Panel Indicators

8

Item

Indicator

Icon

Description

 

 

 

 

1

Power-on indicator

 

The power-on indicator lights green when at least

 

 

 

one power supply module is supplying power to

 

 

 

the storage enclosure.

2

Standby power indicator

 

The standby power indicator lights green when the

 

 

 

system is in standby mode and the main power is

 

 

 

off.

3

System identification

 

The system identification indicator lights white and

 

indicator

 

helps locate a particular enclosure within a rack.

4

Over temperature

 

The over temperature indicator lights amber when

 

indicator

 

the temperature of the system has reached an

 

 

 

unsafe condition.

5

Service action required

 

The Service action required indicator lights amber

 

indicator (system)

 

when there is a fault in one of the components in

 

 

 

the system.

6Service action allowed indicator (system)

CAUTION: Remove the physical disk drawer from the system only if the Service action allowed indicator lights blue. Removing the physical disk drawer from the system when the Service action allowed indicator is off may damage the system.

NOTE: The Service action allowed indicator LED is not used in server attached configurations.

Blue

Indicates that you can safely

 

remove the physical disk

 

drawer from the system.

 

 

Off

Indicates that you cannot

 

 

 

remove the physical disk

 

 

 

drawer from the system.

7

Service action required

Amber

Indicates that the cable is

 

indicator (drawer)

 

 

attached and at least one

 

 

 

 

 

 

lane has a link up status, but

 

 

 

at least one lane has a link

 

 

 

down status.

 

 

Off

Indicates that:

 

 

 

• No cable is attached.

• A cable is attached, and all lanes have a link up status.

• A cable is attached, and all lanes have a link down status.

9

Item

Indicator

Icon

Description

 

 

 

 

 

 

8

Drive activity indicator

 

NOTE: The associated physical disk is

 

 

 

 

 

 

indicated by a number (0 to 11) that is

 

 

 

displayed above the drive activity indicator.

 

 

 

For example, for physical disk 2 on the

 

 

 

physical disk drawer, the drive activity

 

 

 

indicator has 2 displayed above the drive

 

 

 

activity indicator.

 

 

 

Green

Indicates that power is on

 

 

 

 

and the physical disk is

 

 

 

 

operating normally.

 

 

 

Blinks green

Indicates I/O activity for that

 

 

 

 

physical disk.

 

 

 

Off

Indicates that there is no

 

 

 

 

power reaching the drive or

 

 

 

 

a drive is not installed.

Back-Panel Features

NOTE: The following illustration displays the Dell PowerVault MD3860f storage enclosure.

Figure 4. Back-Panel Features

 

 

1.

cooling fan module (2)

2.

power supply switch (2)

3.

USB port

4.

raid controller module (2)

5.power supply module (2)

10

Cooling Fan Module LED Indicator Codes

Figure 5. Cooling Fan Module Indicators

Item

Indicator

Icon

Description

 

 

 

 

1

Power indicator

 

The power indicator lights green when power to

 

 

 

the cooling fan module is available.

2Service action required indicator

3Service action allowed indicator

The Service action required indicator lights amber when there is a fault in the cooling fan module.

CAUTION: Remove the cooling fan module from the system only if the Service action allowed indicator lights blue. Removing the cooling fan module from the system when the Service action allowed indicator is off may damage the system.

NOTE: The Service action allowed indicator LED is not used in server attached configurations.

Blue

Indicates that you can safely

 

remove the cooling fan

 

module from the system.

Off

Indicates that you cannot

 

remove the cooling fan

 

module from the system.

11

Power Supply Module Features And Indicators

NOTE: Your storage array is shipped with two IEC C19 to C20 jumper cords. Connect the C19 plug to the array's power supplies and the C20 plug to the power distribution unit (PDU) in the rack cabinet.

Figure 6. Power Supply Module Features and Status Indicators

Item

Indicator or Connector Icon

Description

 

 

 

 

1

Power connector

Connect the external power supply source to this

 

 

connector.

 

2

Power switch

The power switch controls the power supply

 

 

output to the system.

 

3

Standby power indicator

The standby power indicator lights green when the

 

 

system is in standby mode and the main power is

 

 

off.

 

4

DC power indicator

Green

Indicates that DC output

 

 

 

 

 

voltage is within the limit.

 

 

Off

Indicates that DC output

 

 

 

voltage is not within the

 

 

 

limit.

5Service action allowed indicator

CAUTION: Remove the power supply module from the system only if the service action allowed indicator lights blue. Removing the power supply module from the system when the service action allowed indicator is off may damage the system.

Blue

Indicates that you can safely

 

remove the power supply

 

module from the system.

12

Item

Indicator or Connector Icon

Description

 

 

 

 

 

 

 

Off

Indicates that you cannot

 

 

 

remove the power supply

 

 

 

module from the system.

6Service action required indicator

7AC power indicator

The service action required indicator lights amber when there is a fault in the power supply module.

Green

Indicates that AC output

 

voltage is within the limit.

Off

Indicates that AC output

 

voltage is not within the

 

limit.

Physical-Disk LED Indicators

Figure 7. Physical-Disk LED Indicators

13

Item

Indicator

Icon

Description

 

 

 

 

 

1

Service action allowed

 

 

CAUTION: Remove the physical disk from

 

indicator

 

 

 

 

 

the system only if the service action allowed

 

 

 

 

 

 

 

 

indicator lights blue. Removing the physical

 

 

 

 

disk from the system when the service action

 

 

 

 

allowed indicator is off may damage the

 

 

 

 

system.

 

 

 

Blue

Indicates that you can safely

 

 

 

 

remove the physical disk

 

 

 

 

from the system.

 

 

 

Off

Indicates that you cannot

 

 

 

 

remove the physical disk

 

 

 

 

from the system.

2

Service action required

 

The service action required indicator lights amber

 

indicator

 

when there is a fault in the physical disk.

14

2

Controller Modules

RAID Controller Modules

RAID controller modules provide high-performance, advanced virtual disk configuration, and faulttolerant disk subsystem management. Each RAID controller module contains 4 GB of mirrored cache for high availability and is protected by a battery powered cache offload mechanism.

NOTE: 8 GB mirrored cache is an optional feature.

RAID controller modules provide the following data path and enclosure management functions:

Monitoring and controlling enclosure environment elements (temperature, fans, power supplies, and enclosure LEDs)

Controlling access to the physical disks

Communicating enclosure attributes and states to the host server and management station

MD3860f Fibre Channel RAID Controller Module Features

And Indicators

Figure 8. MD3860f Fibre Channel RAID Controller Module Features and Indicators

Item

Indicator, Button, or

Icon

Description

 

Connector

 

 

 

 

 

 

1

Ethernet management

 

Provides a 100/1000 Mbps Ethernet connection for out-

 

port

 

of-band management of the enclosure.

2

Reserved Ethernet port

 

Reserved port.

15

Item

Indicator, Button, or

Icon

Description

 

Connector

 

 

 

 

 

 

3

12 Gbps SAS IN port (2)

 

Provides host-to-controller SAS connection.

4

USB port

 

Reserved port.

5

Mini USB port

 

Dell support only.

6

Password reset switch

 

Pressing this switch resets the password.

7

SAS expansion port (2)

 

Provides SAS OUT connection for cabling to a daisy

 

 

 

chained expansion enclosure. Port 0 expansion port is

 

 

 

recommended.

8

16 Gbps FC IN port (4)

 

Provides host-to-controller SAS connection.

9

Seven segment display

 

Displays status or error codes for the storage array.

 

sequence

 

 

10

System identification

 

The system identification indicator blinks blue when

 

indicator

 

system identification switch push-button on the

 

 

 

enclosure front panel is pressed.

11

Controller fault

 

The controller fault indicator lights amber when controller

 

indicator

 

fault is detected.

12

Controller power

 

The controller power indicator lights green when

 

indicator

 

controller power is on.

13

Cache active or cache

 

The cache active or cache offload indicator lights green

 

offload indicator

 

when on-board controller memory contains data.

 

 

 

If AC power fails, this LED changes to indicate cache

 

 

 

offload status.

 

 

 

If the password reset function has successfully changed

 

 

 

the password, this LED flashes on and off briefly.

14

Battery fault indicator

 

The battery fault indicator lights amber when battery

 

 

 

backup unit or battery has failed.

Host Channel LED Link Rate Indications

Above each FC port is a pair of LED indicators. The status of any FC port can be determined by applying the condition of each LED pair.

Table 1. LED Status Indicators

LED 0

LED 1

Port Status

 

 

 

Off

Off

Link down

On

Off

4 Gbps link

Off

On

8 Gbps link

On

On

16 Gbps link

16

SFP+ Transceivers Fibre Optic And SAS Cables

NOTE: Your small form-factor pluggable (SFP+) transceivers and cables may look different from the ones shown below. The differences do not affect the performance of the SFP+ transceivers.

FC host connections may operate at 4 Gbps, 8 Gbps, or 16 Gbps. Ports for 16 Gbps Fibre Channel host connections require SFP+ transceivers designed for this data rate. SFP+ transceivers that support other data rates are incompatible.

WARNING: Do not disassemble or remove any part of a SFP+ transceiver due to the possibility of being exposed to laser radiation.

Figure 9. Fibre Optic Cable Connection

 

 

1.

FC IN slot (4)

2.

SFP+ transceiver

3.

fibre optic cable

4.

gate

The RAID controller expansion ports support SAS expansion connections. The following figure shows a SAS cable and an SFF-8088 connector.

17

Loading...
+ 38 hidden pages