DE DIETRICH MCR 24 User Manual

5 (1)

Vivadens

EN

Wall-hung gas condensing boilers

MCR 24

MCR 24/28 MI

MCR 30/35 MI

MCR 34/39 MI

User Guide

300015874-001-01

Contents

1

Introduction ................................................................................................

 

 

4

 

1.1

Symbols used .......................................................

4

 

1.2

Abbreviations ........................................................

4

 

1.3

General

..................................................................

4

 

 

1.3.1

Manufacturer’s liability .............................................

4

 

 

1.3.2

Installer’s liability .....................................................

5

 

 

1.3.3

User’s liability ..........................................................

5

 

1.4

Homologations ......................................................

6

 

 

1.4.1

Certifications ...........................................................

6

2

Safety instructions and recommendations ..............................................

7

 

2.1

Safety instructions ...............................................

7

 

2.2

Recommendations ................................................

8

3

Description ..................................................................................................

 

 

9

 

3.1

General description ..............................................

9

 

3.2

Main parts ..............................................................

9

 

3.3

Control panel .......................................................

10

4

Operating the appliance ..........................................................................

 

 

11

 

4.1

Start the boiler ....................................................

11

 

4.2

Reading out measured values ...........................

12

 

4.3

Changing the settings ........................................

13

 

 

4.3.1

Changing the heating temperature ........................

13

 

 

4.3.2

Changing the domestic hot water

 

 

 

 

temperature ...........................................................

14

 

 

4.3.3

Modifying the comfort setting (ECO) .....................

14

 

 

4.3.4

StoppingthecentralheatingoractivatingtheSummer

 

 

 

mode .....................................................................

15

 

 

4.3.5

Stopping domestic hot water production ...............

16

 

 

4.3.6

Other settings ........................................................

16

1

 

 

 

160513 - 300015874-001-01

 

 

Contents

 

 

4.4

Installation shutdown .........................................

17

4.5

Turning on the antifreeze function ....................

18

5

Checking and maintenance

.....................................................................

19

 

5.1

General instructions ...........................................

19

 

5.2

Periodic checks ..................................................

19

 

5.3 ...............................................

Filling the system

20

 

5.4 .............................

Bleeding the heating system

21

 

5.5 .....................................

Draining the installation

24

6

Troubleshooting .......................................................................................

 

 

25

 

6.1

Error codes ..........................................................

25

 

 

6.1.1

..............................................................................

25

 

 

6.1.2

..............................................................................

25

 

 

6.1.3

Other error codes ..................................................

25

 

 

6.1.4

Before contacting the installer ...............................

25

 

6.2

Incidents and solutions ......................................

26

7

Technical specifications ..........................................................................

 

 

28

 

7.1

Technical specifications ....................................

28

8

Energy savings .........................................................................................

 

 

30

 

8.1

Energy savings ...................................................

30

 

 

8.1.1

Energy-saving advice ............................................

30

 

 

8.1.2

Room thermostat and settings ..............................

30

9

Warranty ....................................................................................................

 

 

32

 

9.1

General

................................................................

32

 

9.2

Warranty terms ...................................................

32

2

 

 

 

160513 - 300015874-001-01

 

 

3

 

 

 

160513 - 300015874-001-01

 

 

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

1. Introduction

1Introduction

1.1Symbols used

In these instructions, various danger levels are employed to draw the user’s attention to particular information. In so doing, we wish to safeguard the user’s safety, obviate hazards and guarantee correct operation of the appliance.

DANGER

Risk of a dangerous situation causing serious physical injury.

WARNING

Risk of a dangerous situation causing slight physical injury.

CAUTION

Risk of material damage.

Signals important information.

¼Signals a referral to other instructions or other pages in the instructions.

1.2Abbreviations

4DHW: Domestic hot water.

4IRC: Interactive remote control.

4CRC: Communicating remote controller.

4Hi: Lower heating value LHV (Nett).

4Hs: Higher heating value HHV (Gross).

1.3General

1.3.1.Manufacturer’s liability

Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore

delivered with [marking and all relevant documentation.

160513 - 300015874-001-01

 

 

 

4

 

 

1. Introduction

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.

Our liability as the manufacturer may not be invoked in the following cases:

4Failure to abide by the instructions on using the appliance.

4Faulty or insufficient maintenance of the appliance.

4Failure to abide by the instructions on installing the appliance.

1.3.2.Installer’s liability

The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions:

4Read and follow the instructions given in the manuals provided with the appliance.

4Carry out installation in compliance with the prevailing legislation and standards.

4Perform the initial start up and carry out any checks necessary.

4Explain the installation to the user.

4If a maintenance is necessary, warn the user of the obligation to check the appliance and maintain it in good working order.

4Give all the instruction manuals to the user.

1.3.3.User’s liability

To guarantee optimum operation of the appliance, the user must respect the following instructions:

4Read and follow the instructions given in the manuals provided with the appliance.

4Call on qualified professionals to carry out installation and initial start up.

4Get your installer to explain your installation to you.

4Have the required checks and services done.

4Keep the instruction manuals in good condition close to the appliance.

This appliance is not intended to be used by persons (including children) whose physcial, sensory or mental capacity is impaired or persons with no experience or knowledge, unless they have the benefit, through the intermediary of a person responsible for their safety, of supervision or prior instructions regarding use of the appliance. Care should be taken to ensure that children do not play with the appliance.

To prevent hazardous situations from arising, if the mains lead is damaged it must be replaced by the original manufacturer, the manufacturer’s dealer or another suitably skilled person.

5

 

 

 

160513 - 300015874-001-01

 

 

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

1. Introduction

1.4Homologations

1.4.1.Certifications

CE identification no

PIN 0063BQ3009

NOx

< 70 mg/kWh

Type of connection

Chimney: B23P

 

Flue gas outlet: C13,C33,C43,C53,C63,C83, C93

160513 - 300015874-001-01

 

 

 

6

 

 

2. Safety instructions and recommendations

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

2Safety instructions and recommendations

2.1Safety instructions

DANGER

If you smell gas:

1. Do not use a naked flame, do not smoke, do not operate electrical contacts or switches ( doorbell, light, motor, lift, etc..).

2. Shut off the gas supply.

3. Open the windows.

4. Evacuate the premises.

5. Call your fitter.

DANGER

If you smell flue gases:

1. Switch the appliance off.

2. Open the windows.

3. Evacuate the premises.

4. Call your fitter.

WARNING

Depending on the settings of the appliance:

4 Thetemperatureofthefluegasconduitsmayexceed 60°C.

4 The temperature of the radiators may reach 85°C.

4 Thetemperatureofthedomestichotwatermayreach 65°C.

CAUTION

Do not neglect to service the appliance:

4 For completely safe and optimum operation, you must have your boiler regularly serviced by an approved installer.

7

 

 

 

160513 - 300015874-001-01

 

 

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

2. Safety instructions and recommendations

2.2Recommendations

WARNING

Only qualified professionals are authorised to work on the appliance and the installation.

4Regularly check the water pressure in the installation (minimum pressure 0,8 bar, recommended pressure between 1,5 and 2,0 bar).

4Keep the appliance accessible at all times.

4Never remove or cover labels and rating plates affixed to the appliance.Labelsandratingplatesmustbelegiblethroughoutthe entire lifetime of the appliance.

4The appliance should be on Summer or Antrifreeze mode rather than switched off to guarantee the following functions:

-Anti blocking of pumps

-Antifreeze protection

160513 - 300015874-001-01

 

 

 

8

 

 

DE DIETRICH MCR 24 User Manual

3. Description

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

3Description

3.1General description

Wall-hung gas condensing boilers

4MCR 24 - Heating only.

4MCR ../.. MI - Heating and instantaneous domestic hot water production.

4Low pollutant emissions.

4Flue gas discharge via a forced flue, chimney, bi-flow or 3CE type connection.

The MCR 24 boiler can be connected to a 80 or 130 litre tank to produce domestic hot water.

3.2Main parts

 

1

 

2

 

3

 

4

15

5

 

6

14

7

 

13

8

 

16

9

12

10

 

11

 

12

 

13

 

14

T004250-A

15

 

 

16

Automatic air vent

Flue gas discharge pipe / Combustive air

Outlet for measuring combustion gases

Heat exchanger

Air/gaz canal

Fan air inlet Gas block

Display

Control panel

Pressure gauge

Circulating pump

Ignition transformer

Expansion vessel heating circuit (Except MCR 34/39 MI model )

Ignition/ionization electrode

Stand-offframe(optional),Mountingframe,deliveredwith the boiler

Water pressure sensor

9

 

 

 

160513 - 300015874-001-01

 

 

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

3. Description

3.3Control panel

AMenu key

BDisplay

CMain ON/OFF switch

D

Pressure gauge

ESweep key

F( or RESET key

G

Heating temperature key or -

HDHW temperature key or +

JSERVICE or U key

The display indicates the state of the boiler and any errors. The symbols located above the function keys indicate their current function.

Pressing on any key will display the current status of the boiler and the current command code. If there is a fault, the corresponding code continues to be displayed.

160513 - 300015874-001-01

 

 

 

10

 

 

Loading...
+ 25 hidden pages