DE DIETRICH DTG 1300-24 User Manual

0 (0)

ECODENS

EN

Gas fired condensing boiler

DTG 1300-24 Eco / V130

User Guide

300010111-001-B

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

1.1 Symbols and abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.1 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.3 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.3 Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2 Safety instructions and recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

2.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.1 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 3.2 Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4 Operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

4.1 Starting and stopping the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4.1.1 Start the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4.1.2 Stopping the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4.2 Changing the settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4.2.1 Selecting the operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4.2.2 Changing the heating temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4.2.3 Changing the domestic hot water temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4.3 Prolonged absence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 4.3.1 Switching off the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 4.3.2 Antifreeze protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

5 Checking and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

5.1 General instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 5.2 Periodic checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 5.3 Topping up the boiler with water (If the option is connected) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 5.4 Bleeding the heating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 5.5 Draining the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

6.1 Breakdown codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 6.1.1 Safety alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 6.1.2 Sensor alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 6.1.3 Before contacting the installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 6.2 Incidents and solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 6.2.1 The burner is not working. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 6.2.2 The burner is operating but the radiators are cold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 6.2.3 The domestic hot water does not appear hot enough . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 6.2.4 Hot water takes a very long time to reach certain draw-off points and not others . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

7 Caractéristiques techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

8 Energy savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

8.1 Energy-saving advice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 8.2 Room thermostat and settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

DTG 1300-24 Eco / V130

11/09/09 - 300010111-001-B

1. Introduction

1 Introduction

1.1 Symbols and abbreviations

In these instructions, various markings and pictograms are used to draw your attention to particular information. In so doing, De Dietrich Thermique S.A.S wishes to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance.

DHW: Domestic hot water

Caution danger

Risk of injury and damage to equipment. Attention must be paid to the warnings on safety of persons and equipment.

Important information

Information must be kept in mind to maintain comfort.

ZReference

Refer to another manual or other pages in this instruction manual.

1.2 General

1.2.1Manufacturer's liability

Our products are manufactured in compliance with the essential requirements of the various Directives applicable. They are therefore delivered with 1 marking and all relevant documentation.

In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.

Our liability as the manufacturer may not be invoked in the following cases:

`Incorrect use of the appliance.

`Faulty or insufficient maintenance of the appliance.

`Incorrect installation of the appliance.

1.2.2Installer's liability

The installer is responsible for the installation and inital start up of the appliance.

The installer must respect the following instructions:

`Read and follow the instructions given in the manuals provided with the appliance.

`Carry out installation in compliance with the prevailing legislation and standards.

`Perform the initial start up and carry out any checks necessary.

`Explain the installation to the user.

`Warn the user of the obligation to check the appliance and maintain it in good working order.

`Give all the instruction manuals to the user.

1.2.3User's liability

To guarantee optimum operation of the appliance, the user must respect the following instructions:

`Read and abide by the instructions given in the user manual.

`Call on qualified professionals to carry out installation and initial start up.

`Get your fitter to explain your installation to you.

`Have the required checks and services done.

`Keep the instruction manuals in good condition close to the appliance.

This appliance is not intended to be used by persons (including children) whose physcial, sensory or mental capacity is impaired or persons with no experience or knowledge, unless they have the benefit, through the intermediary of a person responsible for their safety, of supervision or prior instructions regarding use of the appliance. Care should be taken to ensure that children do not play with the appliance.

 

 

3

11/09/09 - 300010111-001-B

DTG 1300-24 Eco / V130

 

1. Introduction

1.3 Certifications

CE identification no

CE-0085BQ0052

Type of connection

Chimney: B23P - B33

 

Forced flue: C13(x) - C33(x) - C43(x) - C53 - C63(x) * - C83(x) - C93(x)

Ignition

Automatic

* Except Belgium and France

 

(x) For Germany only

 

4

DTG 1300-24 Eco / V130

11/09/09 - 300010111-001-B

 

2. Safety instructions and recommendations

2 Safety instructions and recommendations

2.1 Safety instructions

DANGER

If you smell gas:

1.Do not use a bare flame, do not smoke, do not actuate electrical contacts or switches ( doorbell, light, motor, lift, etc..).

2.Cut the gas supply.

3.Open the windows.

4.Evacuate the premises.

5.Call your fitter.

Depending on the settings of the appliance:

`The temperature of the flue gas conduits may exceed 60°C.

`The temperature of the radiators may reach 85°C.

`The temperature of the domestic hot water may reach 65°C.

DANGER

If you smell flue gases:

1.Switch the appliance off.

2.Open the windows.

3.Evacuate the premises.

4.Call your fitter.

Do not neglect to service the appliance:

For completely safe and optimum operation, you must have your boiler regularly serviced by an approved installer.

2.2 Recommendations

The installation and the first start-up must be performed by a qualified professional.

Only qualified professionals are authorised to work on the appliance and the instalation.

`Regularly check the water pressure in the installation (minimum pressure 0.8 bar, recommended pressure between 1.5 and 2 bar).

Precautions against frost

The boiler is fitted with an antifreeze system. In the event of total shutdown of the heating in winter which may lead to the danger of freezing (switching off of radiators and current), we recommend using a correctly dosed anti-freeze product to stop the heating water freezing. Failing this, drain the installation completely (in all cases, consult your fitter).

`Keep the appliance accessible at all times.

`Never remove or cover labels and rating plates affixed to the appliance. Labels and rating plates must be legible throughout the entire lifetime of the appliance.

Aeration

The air inlet into the premises must in no event be obstructed, even partially.

Maintenance

The servicing and cleaning of the boiler and the sweeping of the flue gas pipe and the bleed pot must be done at least once a year by a qualified professional.

We recommend that you take out a maintenance contract.

 

 

5

11/09/09 - 300010111-001-B

DTG 1300-24 Eco / V130

 

DE DIETRICH DTG 1300-24 User Manual

3. Description

3 Description

3.1 General description

ECODENS boilers are floor-standing gas-fired condensing boilers. They are combined with a 130 litre tank to handle domestic hot water production and central heating using radiators or underfloor heating.

The boilers can operate on natural gas or on butane/propane. They are factory set for natural gas H.

3.2 Control panel

C000773-B

N

Temperature display

The display shows the temperature of the water in the domestic hot water heating outlet when

 

 

there is a request for domestic hot water.

 

 

 

O

Domestic hot water temperature maintenance

With Easymatic remote control:

 

override button

Pressing the button for 1 second makes it possible to override domestic hot water tank loading

 

I

outside the time period programmed in the control unit up to midnight (indicator light O2 flash).

 

 

- Light O1 lit : The burner is ignited to reheat the domestic hot water tank.

 

 

- Light O2 off : No override or programme running.

 

 

- Light O2 lit : Comfort programme activated.

 

 

 

P

Safety shutdown light

Indicates an error in the boiler.

Q

Reset button

To restart the boiler after safety shutdown.

R

Button -

Used only in measurement V, installer Kand sweep Mmode.

S

Button +

Used only in sweep mode M.

T

6-position switch

- .: Stop / Anti-freeze / Bleed.

 

 

- : Domestic hot water (Summer).

 

 

- ": Heating and domestic hot water (Winter).

 

 

- V: Measurement mode (Key to access the parameters reserved for the installer).

 

 

- K: Fitter mode (Key to access the parameters reserved for the installer).

 

 

- M: Sweeping mode (Key to access the parameters reserved for the installer).

U

"Heating" on light

The light is on when the heating/domestic hot water reversal valve is in the heating position and the

 

 

circulator pump is operating.

V

Heating temperature setting

Setting range: 30 °C to 90 °C (Hard spot at 68°C).

W

Flame presence light

The light is on when the burner is operating.

X

Setting the domestic water temperature

Setting range: 40 °C to 60 °C (Hard spot at 55°C).

Y

"Domestic hot water" on light

The light is on when the heating/domestic hot water reversal valve is in the domestic hot water

 

 

position and the circulator pump is operating.

 

 

 

Z

Pressure indicator

Indicates the pressure in the heating circuit from 0.5 to 2.5 bar.

6