INISOL DUO E DIETRISOL DUO E
EN |
Solar hot water calorifer
BSC...E - BSP...E - BESC...E
User Guide
M000773
300027781-001-01
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.1 Symbols and abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.1 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.3 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.4 Compliance of design and manufacture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.5 Electrical compliance / Marking 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2 Safety instructions and recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.1 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3.1.1 Double coil hot water tank: BSC / BSP...E. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3.1.2 Electro-solar hot water tank: BESC...E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 3.2 Main parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 3.3 Programming and setting the electrical back-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 3.4 Setting the thermostatic mixing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 Diemasol A solar regulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
4.1 General description of how the unit operates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 4.2 Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 4.3 Adjustment keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 4.4 LED message code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 4.5 Measured values and adjustment parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
5 Checking and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5.1 Solar installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2 Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.1 Magnesium anodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.2 Safety valve or safety unit (on cold water inlet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.3 Descaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.4 Casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.5 Vent device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.3 Solar circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
2 |
BSC E - BSP E - BESC E |
11/05/12 - 300027781-001-01 |
|
In these instructions, various markings and pictograms are used to draw your attention to particular information. In so doing, De Dietrich Thermique S.A.S wishes to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance.
RiskDangerof a dangerous situation causing serious physical injury.
RiskCautionof material damage.
Specific information.
ZReference
Refer to another manual or other pages in this instruction manual.
Warning |
` |
DHW: Domestic hot water. |
Risk of a dangerous situation causing slight physical |
|
|
injury. |
|
|
Congratulations on choosing a De Dietrich product, a product of quality. We strongly recommend that you read the following instructions in order to guarantee the optimal operation of your appliance. We are sure that you will not be disappointed and that it will satisfy all of your expectations.
Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore delivered with 1 marking and all relevant documentation.
In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.
Our liability as the manufacturer may not be invoked in the following cases:
`Failure to abide by the instructions on using the appliance.
`Faulty or insufficient maintenance of the appliance.
`Failure to abide by the instructions on installing the appliance.
The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions:
`Read and follow the instructions given in the manuals provided with the appliance.
`Carry out installation in compliance with the prevailing legislation and standards.
`Perform the initial start up and carry out any checks necessary.
`Explain the installation to the user.
`If a maintenance is necessary, warn the user of the obligation to check the appliance and maintain it in good working order.
`Give all the instruction manuals to the user.
To ensure the optimum operation of your appliance, we strongly recommend that you abide by the following instructions:
`Read and follow the instructions given in the manuals provided with the appliance.
`Call on qualified professionals to carry out installation and initial start up.
`Get your installer to explain your installation to you.
`To carry out inspections and maintenance required by a qualified professional.
`Keep the instruction manuals in good condition close to the appliance.
This product conforms to the requirements of european directive 97 / 23 / EC, article 3, paragraph 3, on pressure equipment.
|
|
3 |
|
11/05/12 - 300027781-001-01 |
BSC E - BSP E - BESC E |
||
|
1.2.5 Electrical compliance / Marking 1
This product complies to the requirements to the european directives |
Reference Standard: EN 60.335.1. |
|
and following standards: |
• 2004/108/EC Electromagnetic Compatibility Directive |
|
• 2006/95/EC Low Voltage Directive |
||
Reference Standards: EN 50.081.1 / EN 50.082.1 / EN 55.014. |
Any work on the installation must be done by a qualified professional in compliance with the codes of practice and according to the instructions provided.
Have the installation regularly serviced to guarantee that it operates correctly over time.
It is essential to check the magnesium anode in the DHW tank and the installation and heat transporting fluid pressure every two years.
Never cut the power to the solar control system, even during extended absences. The control system protects the installation against overheating in summer when it is running.
During extended absences, we recommend lowering the set point temperature in the solar DHW calorifier to 50°C. When the user is present, the set point must be set to 60°C.
Never drain the installation. Do not replace or add water or solar fluid to the installation. These actions must be carried out by a qualified technician.
Do not modify the control system parameters unless fully conversant with them.
4 |
BSC E - BSP E - BESC E |
11/05/12 - 300027781-001-01 |
|
|
|
BSC 300 E |
BSP 300 E |
BSP 400 E |
BSP 500 E |
Water content |
litres |
300 |
300 |
370 |
500 |
Top up volume |
litres |
104 |
104 |
132 |
183 |
Solar volume |
litres |
196 |
196 |
238 |
317 |
Max operating pressure, DHW |
bar |
7 |
10 |
10 |
10 |
Boiler heat exchanger |
|
|
|
|
|
Maximum operating temperature |
°C |
90 |
90 |
90 |
90 |
Maximum operating pressure |
bar |
10 |
10 |
10 |
10 |
Water content |
litres |
4.3 |
4.3 |
4.9 |
4.9 |
Exchange surface |
m2 |
0.65 |
0.65 |
0.72 |
0.72 |
Pressure drop |
kPa |
3.0 |
3.0 |
3.4 |
3.4 |
Solar exchanger |
|
|
|
|
|
Water content |
litres |
8.9 |
8.9 |
8.9 |
11.1 |
Exchange surface |
m2 |
1.2 |
1.2 |
1.2 |
1.5 |
Performance |
|
|
|
|
|
Primary temperature at 70 °C |
|
|
|
|
|
Power exchanged (1) (3) |
kW |
16 |
16 |
17.5 |
17.5 |
Flow per hour (1) (3) |
l/h |
390 |
390 |
430 |
430 |
Primary temperature at 80 °C |
|
|
|
|
|
Power exchanged (1) (3) |
kW |
21 |
21 |
23 |
23 |
Flow per hour (1) (3) |
l/h |
515 |
515 |
565 |
565 |
Flow in 10 minutes (2) (3) |
l/10 mm |
190 |
190 |
240 |
335 |
Primary temperature at 90 °C |
|
|
|
|
|
Power exchanged (1) (3) |
kW |
26 |
26 |
29 |
29 |
Flow per hour (1) (3) |
l/h |
640 |
640 |
712 |
712 |
Cooling constant Cr * |
Wh/24h·L·K |
0.20 |
0.20 |
0.19 |
0.15 |
* Only in France
(1)Domestic cold water inlet 10 °C - Domestic hot water outlet 45 °C - Primary flow rate 2 m3/h
(2)Domestic cold water inlet 10 °C - Domestic hot water outlet 40 °C - Domestic hot water storage temperature 65 °C - Primary flow rate 2 m3/h
(3)Values measured only on the back-up volume
|
|
5 |
|
11/05/12 - 300027781-001-01 |
BSC E - BSP E - BESC E |
||
|
3.1.2Electro-solar hot water tank: BESC...E
|
|
BESC 300 E |
BESC 400 E |
BESC 500 E |
Water content |
litres |
300 |
370 |
500 |
Top up volume |
litres |
130 |
160 |
210 |
Solar volume |
litres |
170 |
210 |
290 |
Max operating pressure, DHW |
bar |
7 |
7 |
7 |
Solar exchanger |
|
|
|
|
Water content |
litres |
8.9 |
8.9 |
11.1 |
Exchange surface |
m2 |
1.2 |
1.2 |
1.5 |
Electrical back-up |
|
|
|
|
Output of the electrical back-up |
kW |
2.4 |
3.0 |
3.5 |
Reheating time from 15 to 60°C |
|
2 h 50 min |
2 h 50 min |
3 h 10 min |
Cooling constant Cr * |
Wh/24h·L·K |
0.20 |
0.19 |
0.15 |
* Only in France |
|
|
|
|
Composition of the NF CESI INISOL DUO solar systems packages (for France only)
Check the composition of the CESI solar system, which complies with the requirements of the NF CESI mark, using the table below. The references and packages listed must be shown on the invoice for the system sold by the installer.
A system is complete and functional according to the NF CESI mark if all system references appear on the invoice.
The system is composed of the following elements:
•A collector field with 1, 2 or 3 solar collectors.
•A solar domestic hot water tank to which a solar station incorporating a heating pump, an expansion vessel and a Diemasol A control system is to be mounted.
•The solar fluid that protects the installation from frost and corrosion.
The system is delivered to the installer in two units: a roof pack containing the collectors, their mounting system and the hydraulic connections on the one hand, and a cellar pack containing the calorifier, the system components and the solar fluid on the other hand.
CESI System |
|
Array of collectors |
|
|
|
Domestic hot water production |
|
Solar fluid |
||
|
|
|
|
|
|
|
|
|
|
|
|
Number of |
Type of mounting |
package / |
|
DHW calorifier type |
package / |
Volume |
Back-up type |
package / |
|
|
panels |
Reference |
|
Reference |
(litres) |
Reference |
||||
|
|
|
|
|
|
|||||
|
2 |
On roof |
ER 154 |
|
|
|
|
|
|
|
|
100014076 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/1 |
|
Roof-integral |
ER 155 |
|
|
|
EC 332 |
|
|
EG 101 |
2 |
Installation |
|
|
|
|
|
||||
100014077 |
|
BESC 300 E |
|
300 |
Electric |
|||||
300-4 |
|
(> 20°) |
|
|
100006750 |
89807794 |
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 231 |
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
100014741 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
ER 210 |
|
|
|
|
|
|
|
|
100015850 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/1 |
|
Roof-integral |
ER 211 |
|
|
|
Included in |
|
|
Included in |
2 |
Installation |
|
|
|
|
|
||||
300-4 |
100015851 |
|
BESC 300 E |
|
the full |
300 |
Electric |
the full |
||
|
(> 20°) |
|
|
|||||||
(Full package) |
|
|
|
|
|
package |
|
|
package |
|
|
|
|
|
|
|
|
|
|||
|
|
Roof-integral |
ER 214 |
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
100016110 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
BSC E - BSP E - BESC E |
11/05/12 - 300027781-001-01 |
|
CESI System |
|
Array of collectors |
|
|
|
Domestic hot water production |
|
Solar fluid |
||
|
|
|
|
|
|
|
|
|
|
|
|
Number of |
Type of mounting |
package / |
|
DHW calorifier type |
package / |
Volume |
Back-up type |
package / |
|
|
panels |
Reference |
|
Reference |
(litres) |
Reference |
||||
|
|
|
|
|
|
|||||
|
3 |
On roof |
ER 156 |
|
|
|
|
|
|
|
|
100014078 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/1 |
|
Roof-integral |
ER 157 |
|
|
|
EC 332 |
|
|
EG 101 |
3 |
Installation |
|
|
|
|
|
||||
100014079 |
|
BESC 300 E |
|
300 |
Electric |
|||||
300-6 |
|
(> 20°) |
|
|
100006750 |
89807794 |
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 232 |
|
|
|
|
|
|
|
|
3 |
Installation |
|
|
|
|
|
|
|
|
|
100014742 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
ER 154 |
|
|
|
|
|
|
|
|
100014076 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/1 |
|
Roof-integral |
ER 155 |
|
|
|
EC 335 |
|
|
EG 101 |
2 |
Installation |
|
|
|
|
|
||||
100014077 |
|
BESC 400 E |
|
400 |
Electric |
|||||
400-4 |
|
(> 20°) |
|
|
100006753 |
89807794 |
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 231 |
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
100014741 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
On roof |
ER 156 |
|
|
|
|
|
|
|
|
100014078 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/1 |
|
Roof-integral |
ER 157 |
|
|
|
EC 335 |
|
|
EG 101 |
3 |
Installation |
|
|
|
|
|
||||
100014079 |
|
BESC 400 E |
|
400 |
Electric |
|||||
400-6 |
|
(> 20°) |
|
|
100006753 |
89807794 |
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 232 |
|
|
|
|
|
|
|
|
3 |
Installation |
|
|
|
|
|
|
|
|
|
100014742 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
ER 154 |
|
|
|
|
|
|
|
|
100014076 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/2 |
|
Roof-integral |
ER 155 |
|
|
|
EC 333 |
|
|
EG 101 |
2 |
Installation |
|
|
|
|
|
||||
100014077 |
|
BSC 300 E |
|
300 |
Boiler |
|||||
300-4 |
|
(> 20°) |
|
|
100006751 |
89807794 |
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 231 |
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
100014741 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
ER 212 |
|
|
|
|
|
|
|
|
100015852 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/2 |
|
Roof-integral |
ER 213 |
|
|
|
Included in |
|
|
Included in |
2 |
Installation |
|
|
|
|
|
||||
300-4 |
100015853 |
|
BSC 300 E |
|
the full |
300 |
Boiler |
the full |
||
|
(> 20°) |
|
|
|||||||
(Full package) |
|
|
|
|
|
package |
|
|
package |
|
|
|
|
|
|
|
|
|
|||
|
|
Roof-integral |
ER 215 |
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
100016111 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
On roof |
ER 156 |
|
|
|
|
|
|
|
|
100014078 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/2 |
|
Roof-integral |
ER 157 |
|
|
|
EC 333 |
|
|
EG 101 |
3 |
Installation |
|
|
|
|
|
||||
100014079 |
|
BSC 300 E |
|
300 |
Boiler |
|||||
300-6 |
|
(> 20°) |
|
|
100006751 |
89807794 |
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 232 |
|
|
|
|
|
|
|
|
3 |
Installation |
|
|
|
|
|
|
|
|
|
100014742 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
11/05/12 - 300027781-001-01 |
BSC E - BSP E - BESC E |
||
|
CESI System |
|
Array of collectors |
|
|
|
Domestic hot water production |
|
Solar fluid |
||
|
|
|
|
|
|
|
|
|
|
|
|
Number of |
Type of mounting |
package / |
|
DHW calorifier type |
package / |
Volume |
Back-up type |
package / |
|
|
panels |
Reference |
|
Reference |
(litres) |
Reference |
||||
|
|
|
|
|
|
|||||
|
2 |
On roof |
ER 154 |
|
|
|
|
|
|
|
|
100014076 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/2 |
|
Roof-integral |
ER 155 |
|
|
|
EC 336 |
|
|
EG 101 |
2 |
Installation |
|
|
|
|
|
||||
100014077 |
|
BSP 400 E |
|
400 |
Boiler |
|||||
400-4 |
|
(> 20°) |
|
|
100006754 |
89807794 |
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 231 |
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
100014741 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
On roof |
ER 156 |
|
|
|
|
|
|
|
|
100014078 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INISOL DUO/2 |
|
Roof-integral |
ER 157 |
|
|
|
EC 336 |
|
|
EG 101 |
3 |
Installation |
|
|
|
|
|
||||
100014079 |
|
BSP 400 E |
|
400 |
Boiler |
|||||
400-6 |
|
(> 20°) |
|
|
100006754 |
89807794 |
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 232 |
|
|
|
|
|
|
|
|
3 |
Installation |
|
|
|
|
|
|
|
|
|
100014742 |
|
|
|
|
|
|
|
||
|
|
(17°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Composition of the NF CESI DIETRISOL DUO solar systems packages (for France only)
Check the composition of the CESI solar system, which complies with the requirements of the NF CESI mark, using the table below. The references and packages listed must be shown on the invoice for the system sold by the installer.
A system is complete and functional according to the NF CESI mark if all system references appear on the invoice.
The system is composed of the following elements:
•A collector field with 1, 2 or 3 solar collectors.
•A solar domestic hot water tank to which a solar station incorporating a heating pump, an expansion vessel and a Diemasol A control system is to be mounted.
•The solar fluid that protects the installation from frost and corrosion.
The system is delivered to the installer in two units: a roof pack containing the collectors, their mounting system and the hydraulic connections on the one hand, and a cellar pack containing the calorifier, the system components and the solar fluid on the other hand..
CESI System |
|
Array of collectors |
|
|
|
Domestic hot water production |
|
Solar fluid |
||
|
|
|
|
|
|
|
|
|
|
|
|
Number of |
Type of mounting |
package / |
|
DHW calorifier type |
package / |
Volume |
Back-up type |
package / |
|
|
panels |
Reference |
|
Reference |
(litres) |
Reference |
||||
|
|
|
|
|
|
|||||
|
|
On roof |
ER 432 |
|
|
|
|
|
|
|
|
2 |
(mechanical tiles - |
|
|
|
|
|
|
|
|
|
100019695 |
|
|
|
|
|
|
|
||
|
|
Universal hook) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
On roof |
ER 433 |
|
|
|
|
|
|
|
|
(Slates) |
100019696 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
On roof |
ER 434 |
|
|
|
|
|
|
|
|
2 |
(mechanical tiles - |
|
|
|
|
|
|
|
|
DIETRISOL DUO |
100019697 |
|
|
|
EC 332 |
|
|
EG 100 |
||
|
On rafter) |
|
BESC 300 E |
|
300 |
Electric |
||||
|
|
|
|
|||||||
E 300-4 |
|
|
|
|
|
100006750 |
89807792 |
|||
|
Roof-integral |
ER 442 |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
(> 20°) |
100019705 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
(mechanical tiles) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof-integral |
ER 446 |
|
|
|
|
|
|
|
|
2 |
Installation |
|
|
|
|
|
|
|
|
|
(> 20°) |
100019709 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
(Slates / Flat tile) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8 |
BSC E - BSP E - BESC E |
11/05/12 - 300027781-001-01 |
|