DE DIETRICH BSCE, BSPE, BESCE User Manual

0 (0)
DE DIETRICH BSCE, BSPE, BESCE User Manual

INISOL DUO E DIETRISOL DUO E

EN

Solar hot water calorifer

BSC...E - BSP...E - BESC...E

User Guide

M000773

300027781-001-01

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

1.1 Symbols and abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.1 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.3 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.4 Compliance of design and manufacture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.2.5 Electrical compliance / Marking 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2 Safety instructions and recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.1 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3.1.1 Double coil hot water tank: BSC / BSP...E. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3.1.2 Electro-solar hot water tank: BESC...E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 3.2 Main parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 3.3 Programming and setting the electrical back-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 3.4 Setting the thermostatic mixing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

4 Diemasol A solar regulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

4.1 General description of how the unit operates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 4.2 Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 4.3 Adjustment keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 4.4 LED message code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 4.5 Measured values and adjustment parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

5 Checking and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

5.1 Solar installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2 Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.1 Magnesium anodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.2 Safety valve or safety unit (on cold water inlet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.3 Descaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.4 Casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.2.5 Vent device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.3 Solar circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

2

BSC E - BSP E - BESC E

11/05/12 - 300027781-001-01

 

1 Introduction

1.1 Symbols and abbreviations

In these instructions, various markings and pictograms are used to draw your attention to particular information. In so doing, De Dietrich Thermique S.A.S wishes to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance.

RiskDangerof a dangerous situation causing serious physical injury.

RiskCautionof material damage.

Specific information.

ZReference

Refer to another manual or other pages in this instruction manual.

Warning

`

DHW: Domestic hot water.

Risk of a dangerous situation causing slight physical

 

 

injury.

 

 

1.2 General

Congratulations on choosing a De Dietrich product, a product of quality. We strongly recommend that you read the following instructions in order to guarantee the optimal operation of your appliance. We are sure that you will not be disappointed and that it will satisfy all of your expectations.

1.2.1Manufacturer's liability

Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore delivered with 1 marking and all relevant documentation.

In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.

Our liability as the manufacturer may not be invoked in the following cases:

`Failure to abide by the instructions on using the appliance.

`Faulty or insufficient maintenance of the appliance.

`Failure to abide by the instructions on installing the appliance.

1.2.2Installer's liability

The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions:

`Read and follow the instructions given in the manuals provided with the appliance.

`Carry out installation in compliance with the prevailing legislation and standards.

`Perform the initial start up and carry out any checks necessary.

`Explain the installation to the user.

`If a maintenance is necessary, warn the user of the obligation to check the appliance and maintain it in good working order.

`Give all the instruction manuals to the user.

1.2.3User's liability

To ensure the optimum operation of your appliance, we strongly recommend that you abide by the following instructions:

`Read and follow the instructions given in the manuals provided with the appliance.

`Call on qualified professionals to carry out installation and initial start up.

`Get your installer to explain your installation to you.

`To carry out inspections and maintenance required by a qualified professional.

`Keep the instruction manuals in good condition close to the appliance.

1.2.4Compliance of design and manufacture

This product conforms to the requirements of european directive 97 / 23 / EC, article 3, paragraph 3, on pressure equipment.

 

 

3

11/05/12 - 300027781-001-01

BSC E - BSP E - BESC E

 

1.2.5 Electrical compliance / Marking 1

This product complies to the requirements to the european directives

Reference Standard: EN 60.335.1.

and following standards:

• 2004/108/EC Electromagnetic Compatibility Directive

• 2006/95/EC Low Voltage Directive

Reference Standards: EN 50.081.1 / EN 50.082.1 / EN 55.014.

2 Safety instructions and recommendations

2.1 Safety instructions

Any work on the installation must be done by a qualified professional in compliance with the codes of practice and according to the instructions provided.

2.2 Recommendations

Have the installation regularly serviced to guarantee that it operates correctly over time.

It is essential to check the magnesium anode in the DHW tank and the installation and heat transporting fluid pressure every two years.

Never cut the power to the solar control system, even during extended absences. The control system protects the installation against overheating in summer when it is running.

During extended absences, we recommend lowering the set point temperature in the solar DHW calorifier to 50°C. When the user is present, the set point must be set to 60°C.

Never drain the installation. Do not replace or add water or solar fluid to the installation. These actions must be carried out by a qualified technician.

Do not modify the control system parameters unless fully conversant with them.

4

BSC E - BSP E - BESC E

11/05/12 - 300027781-001-01

 

3 Technical description

3.1 Technical specifications

3.1.1Double coil hot water tank: BSC / BSP...E

 

 

BSC 300 E

BSP 300 E

BSP 400 E

BSP 500 E

Water content

litres

300

300

370

500

Top up volume

litres

104

104

132

183

Solar volume

litres

196

196

238

317

Max operating pressure, DHW

bar

7

10

10

10

Boiler heat exchanger

 

 

 

 

 

Maximum operating temperature

°C

90

90

90

90

Maximum operating pressure

bar

10

10

10

10

Water content

litres

4.3

4.3

4.9

4.9

Exchange surface

m2

0.65

0.65

0.72

0.72

Pressure drop

kPa

3.0

3.0

3.4

3.4

Solar exchanger

 

 

 

 

 

Water content

litres

8.9

8.9

8.9

11.1

Exchange surface

m2

1.2

1.2

1.2

1.5

Performance

 

 

 

 

 

Primary temperature at 70 °C

 

 

 

 

 

Power exchanged (1) (3)

kW

16

16

17.5

17.5

Flow per hour (1) (3)

l/h

390

390

430

430

Primary temperature at 80 °C

 

 

 

 

 

Power exchanged (1) (3)

kW

21

21

23

23

Flow per hour (1) (3)

l/h

515

515

565

565

Flow in 10 minutes (2) (3)

l/10 mm

190

190

240

335

Primary temperature at 90 °C

 

 

 

 

 

Power exchanged (1) (3)

kW

26

26

29

29

Flow per hour (1) (3)

l/h

640

640

712

712

Cooling constant Cr *

Wh/24h·L·K

0.20

0.20

0.19

0.15

* Only in France

(1)Domestic cold water inlet 10 °C - Domestic hot water outlet 45 °C - Primary flow rate 2 m3/h

(2)Domestic cold water inlet 10 °C - Domestic hot water outlet 40 °C - Domestic hot water storage temperature 65 °C - Primary flow rate 2 m3/h

(3)Values measured only on the back-up volume

 

 

5

11/05/12 - 300027781-001-01

BSC E - BSP E - BESC E

 

3.1.2Electro-solar hot water tank: BESC...E

 

 

BESC 300 E

BESC 400 E

BESC 500 E

Water content

litres

300

370

500

Top up volume

litres

130

160

210

Solar volume

litres

170

210

290

Max operating pressure, DHW

bar

7

7

7

Solar exchanger

 

 

 

 

Water content

litres

8.9

8.9

11.1

Exchange surface

m2

1.2

1.2

1.5

Electrical back-up

 

 

 

 

Output of the electrical back-up

kW

2.4

3.0

3.5

Reheating time from 15 to 60°C

 

2 h 50 min

2 h 50 min

3 h 10 min

Cooling constant Cr *

Wh/24h·L·K

0.20

0.19

0.15

* Only in France

 

 

 

 

Composition of the NF CESI INISOL DUO solar systems packages (for France only)

Check the composition of the CESI solar system, which complies with the requirements of the NF CESI mark, using the table below. The references and packages listed must be shown on the invoice for the system sold by the installer.

A system is complete and functional according to the NF CESI mark if all system references appear on the invoice.

The system is composed of the following elements:

A collector field with 1, 2 or 3 solar collectors.

A solar domestic hot water tank to which a solar station incorporating a heating pump, an expansion vessel and a Diemasol A control system is to be mounted.

The solar fluid that protects the installation from frost and corrosion.

The system is delivered to the installer in two units: a roof pack containing the collectors, their mounting system and the hydraulic connections on the one hand, and a cellar pack containing the calorifier, the system components and the solar fluid on the other hand.

CESI System

 

Array of collectors

 

 

 

Domestic hot water production

 

Solar fluid

 

 

 

 

 

 

 

 

 

 

 

 

Number of

Type of mounting

package /

 

DHW calorifier type

package /

Volume

Back-up type

package /

 

panels

Reference

 

Reference

(litres)

Reference

 

 

 

 

 

 

 

2

On roof

ER 154

 

 

 

 

 

 

 

 

100014076

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/1

 

Roof-integral

ER 155

 

 

 

EC 332

 

 

EG 101

2

Installation

 

 

 

 

 

100014077

 

BESC 300 E

 

300

Electric

300-4

 

(> 20°)

 

 

100006750

89807794

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 231

 

 

 

 

 

 

 

 

2

Installation

 

 

 

 

 

 

 

 

100014741

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

On roof

ER 210

 

 

 

 

 

 

 

 

100015850

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/1

 

Roof-integral

ER 211

 

 

 

Included in

 

 

Included in

2

Installation

 

 

 

 

 

300-4

100015851

 

BESC 300 E

 

the full

300

Electric

the full

 

(> 20°)

 

 

(Full package)

 

 

 

 

 

package

 

 

package

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 214

 

 

 

 

 

 

 

 

2

Installation

 

 

 

 

 

 

 

 

100016110

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

BSC E - BSP E - BESC E

11/05/12 - 300027781-001-01

 

CESI System

 

Array of collectors

 

 

 

Domestic hot water production

 

Solar fluid

 

 

 

 

 

 

 

 

 

 

 

 

Number of

Type of mounting

package /

 

DHW calorifier type

package /

Volume

Back-up type

package /

 

panels

Reference

 

Reference

(litres)

Reference

 

 

 

 

 

 

 

3

On roof

ER 156

 

 

 

 

 

 

 

 

100014078

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/1

 

Roof-integral

ER 157

 

 

 

EC 332

 

 

EG 101

3

Installation

 

 

 

 

 

100014079

 

BESC 300 E

 

300

Electric

300-6

 

(> 20°)

 

 

100006750

89807794

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 232

 

 

 

 

 

 

 

 

3

Installation

 

 

 

 

 

 

 

 

100014742

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

On roof

ER 154

 

 

 

 

 

 

 

 

100014076

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/1

 

Roof-integral

ER 155

 

 

 

EC 335

 

 

EG 101

2

Installation

 

 

 

 

 

100014077

 

BESC 400 E

 

400

Electric

400-4

 

(> 20°)

 

 

100006753

89807794

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 231

 

 

 

 

 

 

 

 

2

Installation

 

 

 

 

 

 

 

 

100014741

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

On roof

ER 156

 

 

 

 

 

 

 

 

100014078

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/1

 

Roof-integral

ER 157

 

 

 

EC 335

 

 

EG 101

3

Installation

 

 

 

 

 

100014079

 

BESC 400 E

 

400

Electric

400-6

 

(> 20°)

 

 

100006753

89807794

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 232

 

 

 

 

 

 

 

 

3

Installation

 

 

 

 

 

 

 

 

100014742

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

On roof

ER 154

 

 

 

 

 

 

 

 

100014076

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/2

 

Roof-integral

ER 155

 

 

 

EC 333

 

 

EG 101

2

Installation

 

 

 

 

 

100014077

 

BSC 300 E

 

300

Boiler

300-4

 

(> 20°)

 

 

100006751

89807794

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 231

 

 

 

 

 

 

 

 

2

Installation

 

 

 

 

 

 

 

 

100014741

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

On roof

ER 212

 

 

 

 

 

 

 

 

100015852

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/2

 

Roof-integral

ER 213

 

 

 

Included in

 

 

Included in

2

Installation

 

 

 

 

 

300-4

100015853

 

BSC 300 E

 

the full

300

Boiler

the full

 

(> 20°)

 

 

(Full package)

 

 

 

 

 

package

 

 

package

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 215

 

 

 

 

 

 

 

 

2

Installation

 

 

 

 

 

 

 

 

100016111

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

On roof

ER 156

 

 

 

 

 

 

 

 

100014078

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/2

 

Roof-integral

ER 157

 

 

 

EC 333

 

 

EG 101

3

Installation

 

 

 

 

 

100014079

 

BSC 300 E

 

300

Boiler

300-6

 

(> 20°)

 

 

100006751

89807794

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 232

 

 

 

 

 

 

 

 

3

Installation

 

 

 

 

 

 

 

 

100014742

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

11/05/12 - 300027781-001-01

BSC E - BSP E - BESC E

 

CESI System

 

Array of collectors

 

 

 

Domestic hot water production

 

Solar fluid

 

 

 

 

 

 

 

 

 

 

 

 

Number of

Type of mounting

package /

 

DHW calorifier type

package /

Volume

Back-up type

package /

 

panels

Reference

 

Reference

(litres)

Reference

 

 

 

 

 

 

 

2

On roof

ER 154

 

 

 

 

 

 

 

 

100014076

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/2

 

Roof-integral

ER 155

 

 

 

EC 336

 

 

EG 101

2

Installation

 

 

 

 

 

100014077

 

BSP 400 E

 

400

Boiler

400-4

 

(> 20°)

 

 

100006754

89807794

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 231

 

 

 

 

 

 

 

 

2

Installation

 

 

 

 

 

 

 

 

100014741

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

On roof

ER 156

 

 

 

 

 

 

 

 

100014078

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INISOL DUO/2

 

Roof-integral

ER 157

 

 

 

EC 336

 

 

EG 101

3

Installation

 

 

 

 

 

100014079

 

BSP 400 E

 

400

Boiler

400-6

 

(> 20°)

 

 

100006754

89807794

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 232

 

 

 

 

 

 

 

 

3

Installation

 

 

 

 

 

 

 

 

100014742

 

 

 

 

 

 

 

 

 

(17°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Composition of the NF CESI DIETRISOL DUO solar systems packages (for France only)

Check the composition of the CESI solar system, which complies with the requirements of the NF CESI mark, using the table below. The references and packages listed must be shown on the invoice for the system sold by the installer.

A system is complete and functional according to the NF CESI mark if all system references appear on the invoice.

The system is composed of the following elements:

A collector field with 1, 2 or 3 solar collectors.

A solar domestic hot water tank to which a solar station incorporating a heating pump, an expansion vessel and a Diemasol A control system is to be mounted.

The solar fluid that protects the installation from frost and corrosion.

The system is delivered to the installer in two units: a roof pack containing the collectors, their mounting system and the hydraulic connections on the one hand, and a cellar pack containing the calorifier, the system components and the solar fluid on the other hand..

CESI System

 

Array of collectors

 

 

 

Domestic hot water production

 

Solar fluid

 

 

 

 

 

 

 

 

 

 

 

 

Number of

Type of mounting

package /

 

DHW calorifier type

package /

Volume

Back-up type

package /

 

panels

Reference

 

Reference

(litres)

Reference

 

 

 

 

 

 

 

 

On roof

ER 432

 

 

 

 

 

 

 

 

2

(mechanical tiles -

 

 

 

 

 

 

 

 

100019695

 

 

 

 

 

 

 

 

 

Universal hook)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

On roof

ER 433

 

 

 

 

 

 

 

 

(Slates)

100019696

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On roof

ER 434

 

 

 

 

 

 

 

 

2

(mechanical tiles -

 

 

 

 

 

 

 

DIETRISOL DUO

100019697

 

 

 

EC 332

 

 

EG 100

 

On rafter)

 

BESC 300 E

 

300

Electric

 

 

 

 

E 300-4

 

 

 

 

 

100006750

89807792

 

Roof-integral

ER 442

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Installation

 

 

 

 

 

 

 

 

(> 20°)

100019705

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mechanical tiles)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof-integral

ER 446

 

 

 

 

 

 

 

 

2

Installation

 

 

 

 

 

 

 

 

(> 20°)

100019709

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Slates / Flat tile)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

BSC E - BSP E - BESC E

11/05/12 - 300027781-001-01

 

Loading...
+ 16 hidden pages