The TX-5B/RX-5B are a pair of CMOS LSIs designed for remote
controlled car applications. They have nine control keys controlling
the motions (i.e. forward, backward, rightward, leftward, trigger 1-trigger 4 functions and the turbo function) of the remote controlled
car.
The TX-5B is housed in DIP-16 package, and the RX-
housed in DIP-22 package.
FEATURES
* Wide operating voltage range
TX-5B: (V
RX-5B: (V
=2.2~12.0V)
DD
=3.0~12.0V)
DD
* Very Low stand-by current for TX-5B
* Auto-power-off function for TX-5B
* Few external components are needed
* Built-in 3.6V zener for RX-5B
* 9 functions remote controller controlling: forward,backward, right,
Never allow a stress to exceed the values listed under "Absolute Maximum Ratings", otherwise the device would
suffer from a permanent damage. Nor is a stress at the listed value be allowed to persist over a period, since an
extended exposure to the absolute maximum rating condition may also affect the reliability of the device, if not
causing a damage thereof.
4BACKWARDThe backward function will be selected when this pin is connected to GND
5FORWARDThe forward function will be selected when this pin is connected to GND
6TURBOThe turbo function will be selected, if this pin is connected to GND
7SCOutput pin of the encoding signal with carrier frequency
8F34F3 and F4 function select (sequential trigger)
9F2F2 function select
10SOOutput pin of the encoding signal without carrier frequency
11VDDPositive power supply
12PCPower control output pin
13OSCOOscillator output pin
14OSCIOscillator input pin
15F1F1 function select
16LEFTThe leftward function will be selected when this pin is connected to GND
RX-5B
Pin No. Symbol Description
1VO2Inverter 2 output pin for signal amplify
2GNDNegative power supply
3SIInput pin of the encoding signal
4OSCIOscillator input pin
5OSCOOscillator output pin
6,8,17,15F1, F2,F3,F4F1,F2,F3,F4 function output pin
The TX-5B/RX-5B are a pair of CMOS LSIs designed for remote controlled car applications. The TX-5B/RX-5B
have nine control keys controlling the motions (i.e. forward, backward, rightward, leftward, and trigger1--trigger4
functions and the turbo function) of the remote controlled car.
1. OVER-CURRENT PROTECTION
An Auto Shut-Off mechanism is built-in according to Toy Safety Requirement and effective during over-current
situation in motor driver. The active high input applying to this Auto Shut-Off pin will turn off the motor. (VT pin,
when unused, has to be connected to ground. The transfer point=1.4V)
2. DATA FORMAT
F1="1"
500Hz, 3/4 duty
F0="0"
3. CODING METHOD
3.1 when a trigger pin is triggered, its data code will correspond to the data format of "F1", while the remaining pins
will have the data format of "F0".
3.2. Data string: start code + data code +parity code + end code
startcode=F1F1F1F1F0
data code =
F B T R L F1F3F4F2
F = ForwardB = BackwardT = TurboR = RightL = Left
F1 = Function1F2 = Function2F3 = Function3F4 = Function4
parity code = for parity check
end code = for (latch data)
* Data code can be any combination of F,B,T,R,L,F1,F2,F3,F4 except for F&B, R&L, F3&F4.
Note: (1) In the table, blank=F0. Rows from "FUNCTION1" to "RIGHT+FUNCTION1" (the last row) are similar for
FUNCTION2, FUNCTION2, FUNCTION2. Thus, we can see from the table that we have more than 50
states of function combinations from 8 control keys.
(2) H = high level.
(3) LRTD pin functions as an option pin for LEFT/RIGHT turbo disable. Please refer to the following table.
"LRTD" Key Selected Output Function
HIGH (OPEN)FORWARD+LEFT (RIGHT)+ TURBOFORWARD+LEFT (RIGHT)+ TURBO
TX-5B output pin (SO) has an inverted phase with
RX-5B input (SI). If TX-5B&RX-5B are connected
without using a RF module, an inverter has to be
inserted between these 2 pins, as shown below.