Datadelay MDU14-9M, MDU14-9MC4, MDU14-10, MDU14-10C4, MDU14-8MC4 Datasheet

...
0 (0)
MDU14
QUAD, ECL-INTERFACED
data
3
1
12
24
13
GND
I1
not shown is also available.
FIXED DELAY LINE (SERIES MDU14)
delay devices,
FEATURES PACKAGES
GND
O1
1
3
Fits 24-pin (400mil) DIP socket
Auto-insertable
O2
Input & outputs fully 100K-ECL interfaced & buffered
MDU14-xx DIP
GND GND
O3
O4
5 6 7
9
11
MDU14-xxM Military DIP
FUNCTIONAL DESCRIPTION
The MDU14-series device is a 4-in-1 digitally buffered delay line. The signal inputs (I1-I4) are reproduced at the outputs (O1-O4), shifted in time by an amount determined by the device dash number (See Table). The delay lines function completely independently of each other.
I1
24
I2
22
I3
20
GND
19
VEE
18
I4
16
N/C
O1
N/C
O2 GND GND
N/C
O3
N/C
O4
N/C
DDU14-xxC4 SMD
GND
13
DDU14-xxMC4 Mil SMD
PIN DESCRIPTIONS
I1-I4 Signal Inputs O1-O4 Signal Outputs VEE -5 Volts GND Ground
inc.
2
23 3 4 5 6 7 8 9 10 11
N/C
22
I2
21
N/C
20
I3
19
GND
18
VEE
17
N/C
16
I4
15
N/C
14
N/C GND
SERIES SPECIFICATIONS
Minimum input pulse width: 40% of total delay
Output rise time: 2ns typical
Supply voltage: -5VDC ± 5%
Power dissipation: 500mw typical (no load)
Operating temperature: to 85° C
Temp. coefficient of total delay: 100 PPM/°C
O3O2O1
100%
100% 100%
VCC GNDI1 I2 I3
O4
100%
I4
Functional block diagram
DASH NUMBER SPECIFICATIONS
Part
Number
MDU14-2 MDU14-2.5 MDU14-3 MDU14-4 MDU14-5 MDU14-6 MDU14-7 MDU14-8 MDU14-9 MDU14-10 MDU14-12.5 MDU14-15 MDU14-20 MDU14-25
NOTE: Any dash number between 2 and 25
Total
Delay (ns)
2.0 ± 1.0
2.5 ± 1.0
3.0 ± 1.0
4.0 ± 1.0
5.0 ± 1.0
6.0 ± 1.0
7.0 ± 1.0
8.0 ± 1.0
9.0 ± 1.0
10.0 ± 1.0
12.5 ± 1.0
15.0 ± 1.0
20.0 ± 1.0
25.0 ± 1.2
1997 Data Delay Devices
Doc #97042 DATA DELAY DEVICES, INC. 1
12/15/97 3 Mt. Prospect Ave. Clifton, NJ 07013
MDU14
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The MDU14 tolerances are guaranteed for input pulse widths and periods greater than those specified in the test conditions. Although the device will function properly for pulse widths as small as 40% of the total delay and periods as small as 80% of the total delay (for a symmetric input), the delays may deviate from their values at low frequency. However, for a given input condition, the deviation will be repeatable from pulse to pulse. Contact technical support at Data
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL MIN MAX UNITS NOTES
DC Supply Voltage V Input Pin Voltage V Storage Temperature T Lead Temperature T
EE
IN STRG LEAD
Delay Devices if your application requires device testing at a specific input condition.
POWER SUPPLY BYPASSING
The MDU14 relies on a stable power supply to produce repeatable delays within the stated tolerances. A 0.1uf capacitor from VEE to GND, located as close as possible to the VEE pin, is recommended. A wide VEE trace and a clean ground plane should be used.
-7.0 0.3 V
VEE - 0.3 0.3 V
-55 150 C 300 C 10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
High Level Output Voltage V Low Level Output Voltage V High Level Input Voltage V Low Level Input Voltage V High Level Input Current I Low Level Input Current I
OH OL
IH
IL IH IL
(0C to 85C)
-1.025 -0.880 V
-1.810 -1.620 V
-1.165 -0.880 V
-1.810 -1.475 V 340
0.5
µA µA
VIH = MAX,50Ω to -2V VIL = MIN, 50Ω to -2V
VIH = MAX VIL = MIN
Doc #97042 DATA DELAY DEVICES, INC. 2
12/15/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
Loading...
+ 2 hidden pages