Danby DAC5110M User Manual

Loading...

Owner’s Use and Care Guide

Guide d’utiliser et soin de Propriètaire

Model • Modèle

DAC 5110M, DAC5210M

CAUTION:

Read and follow all safety rules and operating instructions before first use of this product.

PRÉCAUTION:

Veuillez lire attentivement les consignes de sécurité et les directives d’utilisation avant l’utilisation initial de ce produit.

AIR CONDITIONER

Owner’s Use and Care Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 - 8

Important Safety Information

Features

Installation Instructions

Operating Instructions

Care and Maintenance

Troubleshooting

Warranty

CLIMATISEUR

Guide d’utilisation et soins de Propriètaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9 - 16

Consignes de Sécurité Importantes

Caracteristiques

Consignes d’installation

Consignes d’operation

Soins et Entretien

Dépannage

Garantie

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE: If the air conditioner changes ownership, be sure this manual accompanies the unit.

CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEURE: En cas de revente du climatiseur, ce manuel doit être inclus avec l’appareil.

Danby Products Ltd, Guelph, Ontario Canada N1H 6Z9

Danby Products Inc, Findlay, Ohio USA 45840

V3.11.09 JF

WELCOME

Thank you for choosing a Danby Room Air Conditioner to cool your home. This Owner’s Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.

NOTE: THIS UNIT IS NOT DESIGNED FOR “THROUGH-THE-WALL” INSTALLATION.

For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturers nameplate on the rear panel of the unit.

Model Number:

Serial Number:

Date of Purchase:

This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a Customer Service Representative, call Danby TOLL FREE: 1-800-26- (1-800-263-2629)

CAUTION: Do not leave a room air conditioner unattended in a room where people or animals who cannot react to a failed unit are located. A failed unit can cause extreme overheating and fire in an enclosed, unattended space.

1

IMPORTANT SAFETY INFORMATION

READ ALL SAFETY INFORMATION BEFORE USING

ELECTRICAL

SPECIFICATIONS

1)All wiring must comply with local and national electrical codes and must be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2)Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.

3)This 115V air conditioner uses 10.0 or less nameplate amps and may be used in any properly wired, general purpose household receptacle. See Table 1 for specifications for individual branch circuit.

4)For your safety and protection, this unit is

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

5.0 to 10

18

AWGAmerican Wire Gauge

*Based on copper wire at 60°C temperature rating.

grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician.

5) The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters. See Table 2 for receptacle and fuse information. If it is necessary to use an extension cord to connect your air conditioner, use an approved “air conditioner” extension cord only

(available at most local hardware stores).

6) The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit, above the power cord.

 

TABLE 2

 

Receptacle and Fuse Types

 

 

Rated Volts

120

 

 

Amps

10

 

 

Wall Outlet

 

 

 

 

 

 

 

Fuse Size

15

 

 

 

 

 

 

Time Delay Fuse

Plug Type

(or Circuit Breaker)

 

 

 

 

 

ENERGY-

Your Danby appliance is designed to be highly efficient in energy savings. Follow these

SAVING TIPS

recommendations for greater efficiency.

 

 

1)Select a thermostat setting that suits your comfort needs and leave at that chosen setting.

2)The filter is very efficient in removing airborne particles. Keep the air filter clean. Normally, filters should be cleaned every 2 weeks. More frequent cleaning may be necessary depending on indoor air quality.

3)Use drapes, curtains or shades to keep direct sunlight from penetrating and heating room, but do not allow drapes or curtains to obstruct the air flow

around the unit.

4)Start your air conditioner before the outdoor air becomes hot and uncomfortable, to avoid an initial period of discomfort while the unit is cooling off the room.

5)When outdoor temperatures are cool enough, use HIGH or LOW FAN only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting.

2

FEATURES

Interior Air Inlet

 

Cabinet

Control Panel

 

Exterior

 

 

 

Air Inlet

Interior Air Inlet

 

 

 

 

 

 

 

 

 

 

 

Air FIlter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS

ELECTRIC SHOCK HAZARD: To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.

TOOLS NEEDED FOR INSTALLATION:

Screw Drivers: Phillips and flat head.

Power Drill: 1/8” diameter drill bit.

Pencil

Measuring Tape

Scissors

Carpenters Level

NOTE: Save the shipping carton and packing materials for future storage or transportation. From carton, remove the plastic bag containing the installation hardware kit necessary for the installation of your air conditioner. Please check the contents of hardware kit against the corresponding model check list, prior to installation of the unit. See Fig. 1.

CAUTION: Because the compressor is located on the controls side of the unit (left side), this side will be heavier and more awkward to manipulate. Inadequate support on control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended that you have someone assist you during the installation of this unit.

INSTALLATION HARDWARE

 

3/4” screws (9)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety Lock (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/8” screws (4)

 

 

 

 

 

 

 

 

 

 

 

 

L shaped

 

 

 

 

 

 

 

 

 

 

 

 

 

mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bracket (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adhesive

 

 

 

 

 

 

 

 

Foam Seal (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regular Foam

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Seal (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frame Lock

 

 

 

 

 

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side Curtain RH (1)

Side Curtain LH (1)

Fig. 1

3

Danby DAC5110M User Manual

INSTALLATION INSTRUCTIONS (cont’d)

LOCATION

 

 

A) This room air conditioner is designed to fit

not in a garage nor inside a building.

easily into a single or double hung window. However,

away as possible from

since window designs vary, it may be necessary to

least 30” above the floor or ground.

make some modifications for safe, proper installation.

other objects within a room should

B) Make sure window and frame are structurally

blocking the air flow.

E) Be certain the proper electrical

sound and free from dry and rotted wood.

C) For maximum efficiency, install the air conditioner

reach of the installation. Use only a

circuit rated at 15 amps. All wiring

on a side of the house or building which favours more

accordance with local and national

shade than sunlight. If the unit is in direct sunlight, it

F) DO NOT install unit where

is advisable to provide an awning over the unit.

D) Provide sufficient clearance around the cabinet to

combustible gas is suspected. Your

may fail to operate in air containing

allow for ample air circulation through the unit (See

machine oils), sulfide gas, near hot

Fig. 2). The rear of the unit should be outdoors and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Your unit is designed to evaporate condensation

 

 

 

 

 

 

 

 

 

 

under normal conditions. However, under extreme

 

 

20”

 

 

 

 

 

humidity conditions, excess condensation may cause

 

 

Min

 

 

 

 

 

basepan to overflow to the outside. The unit should be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

installed where condensation run-off cannot drip on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pedestrains or neighboring properties.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30”

Side Min Obstruction

 

 

Fig. 2

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Assembly of the Upper Channel to Cabinet.

• “L” Shaped Top Channel: Install the “L” shaped channel to the top of the cabinet as shown in Fig. 3, using four (4) 3/8” screws.

2) Assembly of the Side Curtains to Cabinet.

Extend the shutter from the shutter frame and slide it into the shutter tabs on the side channel of the air conditioner, as shown in Fig. 4.

Slide the shutters into the top (“L” Shaped) and bottom (“U” Shaped) channels. The shutters are identified (on frame) as left and right.

3) Completing the Installation

• Cut the foam (non adhesive) sealing strip to fit the area of the window sill that the air conditioner will rest on.

“U”

Fig. 3

Slide

down

 

 

 

into

tabs

 

 

 

 

 

Shutter tabs

Shutter

Shutter frame

 

Fig. 4

 

 

 

4