PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

(a)Do not operate or allow the oven to be operated with the door open.

(b)Mark the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) Interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.

(c)Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.

(d)Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.

(e)A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner.

TABLE OF CONTENTS

PROPER USE AND SERVICE PRECAUTIONS

3

SPECIFICATIONS

4

FEATURE DIAGRAM

5

INSTALLATION

6

OPERATION

7

MEASUREMENT OF THE MICROWAVE OUTPUT POWER

8

MICROWAVE RADIATION TEST

9

KOR-6115 WIRING DIAGRAM

10

KOR-61151 WIRING DIAGRAM

11

CIRCUIT DESCRIPTION

12

PRECAUTIONS FOR DISASSEMBLY AND REPAIR

14

DISASSEMBLY AND ASSEMBLY

15

INTERLOCK MECHANISM

20

TROUBLE SHOOTING GUIDE

22

COMPONENT TEST PROCEDURE

24

EXPLODED VIEW AND PARTS LIST

26

2

PROPER USE AND SERVICE PRECAUTIONS

CAUTION : THIS DEVICE IS TO BE SERVICED ONLY BY PROPERLY QUALIFIED SERVICE PERSONNEL. CONSULT THE SERVICE MANUAL FOR PROPER SERVICE PROCEDURES TO ASSURE CONTINUED SAFETY OPERATION AND FOR PRECAUTIONS TO BE TAKEN TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY.

1.For Safe Operation

Damage that allows the microwave energy (that cooks or heats the food) to escape will result in poor cooking and may cause serious bodily injury to the operator.

IF ANY OF THE FOLLOWING CONDITIONS EXIST, OPERATOR MUST NOT USE THE APPLIANCE. (Only a trained service personnel should make repairs.)

1)A broken door hinge.

2)A broken door viewing screen.

3)A broken front panel, oven cavity.

4)A loosened door lock.

5)A broken door lock.

The door gasket plate and even cavity surface should be kept clean.

No grease, soil or spatter should be allowed to build up on these surfaces or inside the oven.

DO NOT ATTEMPT TO OPERATE THIS APPLIANCE WITH THE DOOR OPEN. The microwave Oven has concealed switches to make sure the power is turned off when the door is opened. Do not attempt to defeat them.

DO NOT ATTEMPT TO SERVICE THIS APPLIANCE UNTIL YOU HAVE READ THIS SERVICE MANUAL.

2.For Safe Service Procedures

1)If the oven is operative prior to servicing, a microwave emission check should be performed prior to servicing the oven.

2)If any certified oven unit is found to have excessive emission level 5mW/cm2, the service person should:

(a)inform the manufacturer, importer or assembler,

(b)repair the unit at no cost to the owner,

(c)attempt to ascertain the cause of the excessive leakage,

(d)tell the owner not to use the unit until the oven has been brought into compliance.

3)If the oven operates with the door open, the service person should tell the user not to operate the oven and contact the manufacturer immediately.

CAUTION

MICROWAVE RADIATION

PERSONNEL SHOULD NOT BE EXPOSED TO THE MICROWAVE ENERGY WHICH MAY RADIATE FROM THE MAGNETRON OR OTHER MICROWAVE GENERATING DEVICE IF IT IS IMPROPERLY USED OR CONNECTED. ALL INPUT AND OUTPUT MICROWAVE CONNECTIONS. WAVEGUIDES, FLANGES AND GASKETS MUST BE SECURE. NEVER OPERATE THE DEVICE WITHOUT A MICROWAVE ENERGY ABSORBING LOAD ATTACHED. NEVER LOOK INTO AN OPEN WAVEGUIDE OR ANTENNA WHILE THE DEVICE IS ENERGIZED

3

SPECIFICATIONS

 

 

ITEM

SPECIFICATION

 

 

 

 

POWER SUPPLY

 

120V~60Hz, SINGLE PHASE WITH EARTHING

 

 

 

 

 

 

POWER CONSUMPTION

920 W

 

 

 

 

MICROWAVE

OUTPUT POWER

600 W (IEC 705) (FULL MICROWAVE POWER)

 

 

 

 

 

 

FREQUENCY

2450 MHz

 

 

 

OUTPUT DIMENSIONS (W X H X D)

465 X 274 X 360 mm (18.3 X 10.8 X 14.2 in.)

 

 

 

CAVITY DIMENSIONS (W X H X D)

290 X 200 X 290 mm (11.4 X 7.9 X 11.4 in)

 

 

 

NET WEIGHT

 

APPROX. 12.5 kg (27.6 Ibs.)

 

 

 

TIMER

 

35 min. DUAL SPEED

 

 

 

POWER SELECTIONS

5 LEVELS

 

 

 

CAVITY VOLUME

 

0.64 Cu.Ft.

 

 

 

 

* Specifications are subject to change without notice.

465

360

 

274

4

Daewoo KOR-61151 User Manual

FEATURES DIAGRAM

2

4

1

 

9

12

11

8

3 5

6

7

¤ Safety Interlock System

¤Ł Door Viewing Screen - Allows viewing of food. The screen is designed so that light can pass through, but not the microwave.

¤Ø Door Hook - When the door is closed, it will automatically shut. If the door is opened while the oven is operating, the magnetron will immediately stop operating.

¤Œ Oven Cavity

¤º Door Seal - Door seal maintains the microwave energy within the oven cavity and prevents microwave leakage.

¤Glass Cooking Tray - Made of special heat resistant glass. Food in a proper receptacle is placed on this tray for cooking.

¤Roller Guide - This must always be used for cooking together with the glass cooking tray.

¤Coupler - This fits over the shaft in the center of the oven’s cavity floor. This is to remain in the oven for all cooking.

¤Knob V.P.C - Used to select a microwave power level.

¤Knob Timer - Used in setting cooking time for all functions.

¤æ Door Release Button - By pushing this button the latch system cut off all circuits and stops the oven before the door is opened.

5

INSTALLATION

1

2

3

4

5

Steady, flat location

This microwave oven should be set on a steady, flat surface.

Leave space behind and side

All air vents should be kept a clearance. If all vents are covered during operation, the oven may overheat and, eventually, cause oven failure.

Away from radio, and TV sets

Poor television reception and radio interference may result if the oven is located close to a TV, Radio or antenna, feeder and so on.

Away from heating appliances and water taps

Keep the oven away from hot air, steam or splash when choosing a place to position it, or the insulation might be adversely affected and breakdowns occur.

Power supply

• Check your local power source.

This microwave oven requires a current of approximately 15 amperes, 120 Volts, 60Hz grounded outlet.

Power supply cord is about 1.0 meters long.

1.A short power-supply cord is poovided to reduce the risks resulting from becoming entangled in or tripping over a longer cord.

2.Longer cord sets or extension cords are available and may be used if care is exercised in their use.

3.If a long cord or extension cord is used, (1) the marked electrical rating of the cord set or extension cord should be at least as great as the electrical rating of the appliance, (2) the extension cord must be a grounding-type 3-wire cord, and (3) the longer cord should be arranged so that will not drape over the countertop or tabletop where it can be pulled on by children or tripped over unintentionally.

When use 3-pronged plug

3-prong Receptacle

Receptacle

Box cover

When use a grounding adaptor, make usre the receptacle box is fully grounded

Receptacle Box cover

Grounding Lead

3-prong plug

Grounding Adaptor

 

Receptacle

6 Examine the oven after unpacking for any damage such as:

A misaligned door, Broken door, A dents in cavity.

If any of the above are visible, DO NOT INSTALL, and notify dealer immediately.

6

OPERATION

1

2

3

4

5

6

Connect the main lead to an electrical outlet.

After placing the food in a suitable container, open the oven door and put it on the glass tray. The glass tray must always be in place during cooking.

Close the door securely.

Choose cooking power by setting V.P.C. Knob to the desired position.

Refer to cookbook for recommended power levels.

Determine cooking time. Consult cookbook for recipe timing.

¢” Oven light turns on and cooling fan starts to operate. Microwave cooking starts.

You may open the door while the oven is operating.

NOTE :

As soon as the door is opened, the safety mecha-

1. When setting Timer for less than 2 minutes, turn

nisms stop microwave power and cooking timer.

the Timer past 2 minutes and then return to the

if you wish to change the time during cooking, simply

correct timer setting.

adjust the Timer to the desired time.

 

7 When the timer reaches zero, a bell will ring and the unit will turns off.

¢” Oven light turns off.

If additional cooking time is needed and the door has not been opened, the oven will automatically start when the Timer is reset.

 

0

1

 

 

2

35

 

3

30

 

4

25

 

5

20

 

6

 

 

15

10

2. Various clicking noises may be heard when turning the V.P.C. knob. This is normal and does not affect the operation of your microwave oven.

Variable Power Cooking

ON and OFF cycle time of mechanicial V.P.C. switch is 30 seconds.

When the V.P.C. knob is set to the desired position and timer knob turns to the desired position, the V.P.C. switch has a cycle (ON/OFF time (sec)) listed below.

Variable power setting

ON/OFF time (sec)

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(HIGH)

30/0

100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MED HIGH)

23.2/6.8

77%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MEDIUM)

16.5/13.5

55%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(DEFROST)

9.8/20.2

33%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(WARM)

5/25

17%

 

 

 

 

 

 

 

 

 

7

MEASUREMENT OF THE MICROWAVE OUTPUT POWER

Microwave output power can be checked by indirectly measuring the temperature rise of a certain amount of water exposed to the microwave as directed below.

PROCEDURE

1.Microwave power output measurement is made with the microwave oven supplied at rated voltage and operated at its maximum microwave power setting with a load of 1,000¡ 5cc of potable water.

2.The water is contained in a cylindrical borosilicate glass vessel having a maximum material thickness of 3 mm and an outside diameter of approximately 190 mm.

3.The oven and the empty vessel are at ambient temperature prior to the start of the test. The initial temperature of the water is 10¡ 2˚C (50¡ 3.6˚F).

It is measured immediately before the water is added to the vessel. After addition of the water to the vessel, the load is immediately placed on the center of the shelf which is in the lowest normal position.

4.Microwave power is switched on.

Water Load

5. Heating time should be exactly 49 seconds.

Heating time is measured while the microwave generator is operating at full power.

The filament heat-up time for magnetrons is not included.

6.The initial and final water temperatures are selected so that the maximum difference between the ambient and

final water temperatures is 5K.

Tray

7. The microwave power output P in watts is calculated from the following formula:

P = 4187 X T/t

T is actual temperature rise.

t is the heating time.

The power measured should be 600W¡ 10.0%.

CAUTION :

1. Water load should be measured exactly to 1 liters.

2 Input power voltage should be exactly 230V as specified. 3. Ambient temperature should be 20¡ 2˚C(68¡ 3.6˚F)

8

MICROWAVE RADIATION TEST

WARNING

Make sure to check the microwave leakage before and after repair of adjustment.

Always, start measuring of an unknown field to assure safety for operating personnel from microwave energy.

Do not place your hands into any suspected microwave radiation field unless the safe density level is known.

Care should be taken not to place the eyes in direct line with the source of microwave energy.

Slowly approach the unit under test until the radiometer reads an appreciable microwave leakage from the unit under the test.

PROCEDURE

A)Prepare Microwave Energy Survey Meter, 600cc glass beaker, glass thermometer 100˚C or 212˚F.

B)Pour 275cc¡ 15cc of tap water initially at 20¡ 5˚C(68¡ 9˚F) in the 600cc beaker with an inside diameter of approx. 9.5cm (3.5 in).

C)Place it at the center of the tray and set it in a cavity.

D)Close the door and operate the oven.

E)Measure the leakage by using microwave energy survery meter with dual ranges, set to 2450 MHz. ƒ¡ Measured radiation leakage must not exceed the values prescribed below.

Leakage for a fully assembled oven with door normally closed must be less than 4mW/cm2.

ƒ¡When measuring the leakage, always use the 2 in (5cm) space cone with probe. Hold the probe perpendicular to the cabinet and door. Place the space cone of the probe on the door, cabinet, door seam, door viewing screen, the exhaust air vents and the suction air vents.

ƒ¡Measuring should be in a counter-clockwise direction at a rate of 1 inch/sec. If the leakage of the cabinet door seam is unknow, move the probe more slowly.

ƒ¡When measuring near a corner of the door, keep the probe perpendicular to the areas making sure the probe end at the base of the cone does not get closer than 2 inches from any metal.

If it does, erroneous reading may result.