PRECAUTIONS FOR PROPER USE OF AIR CONDITIONER

Please observe the following instructions.

1.Operate the Selector Switch to run or stop the unit.

-Do not use Main Power Switch or Auxiliary Power Switch to operate unit.

2.Do not stick anything into the air outlet or inlet.

-It is dangerous and it can cause injury or damage.

3.Avoid exposing your body directly to a continuous cool air - flow for long periods.

-It is not good for your health.

4.Do not pour water on the unit to clean it.

-It is dangerous and it can cause injury or damage.

Never use solvents or harsh chemicals when cleaning the unit.

When the air inlet grill and cabinet are dirty, wipe with luke - warm water (below 104°F or 40°C)

5.Avoid placing any obstacles near the inlet or outlet.

-If the inlet or outlet is blocked with any obstacle, it may cause damage to the unit.

6.Do not run or stop the unit frequently.

-If you run or stop the unit more then 4-5 times an hour, it can cause damage to the unit.

7.Wait at least 3 minutes before restarting the unit or in the case of power failure.

-If you turn on the unit within 3 minutes after power off, this can cause damage to the unit.

8.If the air conditioner is operated without an air filter, dust is not removed from the air, and resultant accumulation in the unit may lead to a failure.

-Do not forget to install the air filter.

9.The air filter should be cleaned at least once every two weeks.

10.When the unit is cleaned, set the Selector Switch at off position.

-And then unplug the power plug.

11.Never store gasoline or other flammable liquid near the air conditioner.

-It is very dangerous.

12.Do not force the controls on the front panel too much.

-It can cause damage the controls and the unit.

13.Set a comfortable temperature.

-Very low temperature setting considerably increase power consumption.

14.Be careful to keep room temperature comfortable.

-Avoid continuous direct air flow on you or a sick person while sleeping.

15.Do not remove the plug by pulling the power cord.

-Damage to the cord and may cause shock hazard.

1

TABLE OF CONTENTS

 

1. GENERAL SPECIFICATIONS...............................................................................

2

2. INSTALLATION INSTRUCTIONS .......................................................................

3~8

• WINDOW REQUIREMENTS

 

• BASIC TOOLS NEEDED

 

• SAFETY INSTRUCTIONS

 

• BEFORE INSTALLATION

 

• STEP1-PREPARE COMPONENTS FOR INSTALLATION

 

• STEP2-PREPARE WINDOW FOR INSTALLATION

 

• STEP3-PREPARATION OF CHASSIS

 

• STEP4-PLACING CHASSIS

 

• STEP5-SECURE WINDOW SHUTTER

 

• STEP6-RECHECK INSTALLATION

 

• STEP7-INSTALL UNIT AND ASSEMBLE FRONT GRILLE

 

• STEP8-RECHECK THE ENTIRE INSTALLATION

 

3. NAMES OF MAJOR COMPONENTS .....................................................................

9

4. OPERATION INSTRUCTIONS ............................................................................

10

• FAN & COOLING CONTROL

 

• TEMPERATURE CONTROL

 

5. GENERAL INFORMATION .................................................................................

11

• CHANGING AIR FLOW DIRECTION

 

• AIR FLOW AROUND UNIT

 

• DRAIN HOLE AND WATER DRIPPING OUTSIDE

 

6. CARE AND MAINTENANCE ..............................................................................

12

• AIR FILTER

 

• CLEANING THE AIR CONDITIONER

 

7. ELECTRICAL REQUIREMENTS .........................................................................

13

• ELECTRICAL GROUNDING INSTRUCTIONS.

 

• USE OF EXTENSION CORDS

 

8. BEFORE CALLING FOR SERVICE......................................................................

14

GENERAL SPECIFICATIONS

MODEL

DWC-051C

DWC-072C

DWC-073C

DWC-092C

DWC-094C

ITEM

 

 

 

 

 

 

 

 

 

POWER SOURCE

 

AC 115V, 60Hz, SINGLE PHASE

 

 

 

18.9(W) x 14.6(H) x 19.5(D) inch

 

DIMENSIONS

 

480(W) x 369(H) x 497(D) mm

 

 

 

 

WEIGHT

52.2 Ibs (23.7 Kg)-Approx.

63 Ibs (28.5 Kg)-Approx.

64 Ibs (29 Kg)- Approx.

2

224"TOTo 36"
1415"1/2"MINMIN

INSTALLATION INSTRUCTIONS

• WINDOW REQUIREMENTS

These instructions are provided for a standard double hung window or mobile home double hung window installation in windows 24 inch (610mm) to 36 in (914mm). The upper and lower sash must open sufficiently to allow a clear vertical opening of 15 in (381mm) from

the bottom of the sash to the window sill. Select a centrally located window on the side of the room that

receives the least direct sunlight. There should be no obstruction to air flow either inside(i.e curtains) or outside (i.e fence, wall or

bushes). Read this entire installation manual thoroughly before beginning the

installation.

Make sure you have the necessary tools and other materials for the

job. Study the illustrations in these instructions to become familiar with important details of the installation process.

Read the Use & Care manual to become familiar with the operation of your room air conditioner.

IMPORTANT :

It is important, both for your personal safety and to avoid possible damage to your home, that you observe the safety instructions that are given.

After installing the unit, re-read these instructions to make sure you have completed each step and all parts are fastened in place for a secure installation.

For best results, perform the installation procedure in the order given. Doing so will minimize the time required to install the unit.

• BASIC TOOLS NEEDED

• Standard screwdriver

• Phillips screwdriver

• Sharp knife

• Carpenter’s level

• 1/4” hex driver

• Tape measure

• Electric drill

• 1/8” drill bit

 

• SAFETY INSTRUCTIONS

 

 

CAUTION

• The air conditioner shall be installed in accordance with the national wiring regulation.

1.Install an exclusive main power switch (main circuit breaker) or GFI (Ground Fault Interrupted) switch.

2.Be sure to use grounded power source.

3.Power source for DWC-051C, DWC-072C, DWC-073C, DWC-092C, DWC-094C is 115V.

4.Consumer must pay charges for wiring and installation.

3

• SAFETY INSTRUCTIONS (CONTINUED)

The receptacle should be an individual branch circuit used only for this air conditioner. Be sure the electrical service is adequate for the model air conditioner you have chosen. The complete electrical rating of your air conditioner is stated on the name plate located at the unit’s side. Be sure the plug receptacle is close enough for the power cord to reach it.

WARNING :

An extension cord should not be used with your air conditioner!

To minimize shock and fire hazards, proper grounding is important. For your safety and

protection,this air conditioner is equipped with a special three-prong grounding plug on the service cord.

WARNING :

Do not, under any circumstances, cut or remove the grounding prong on the plug. To do so will create a shock hazard.

Your air conditioner must be plugged into a properly grounded and polarzied three prong receptacle. Do not use an adapter plug. If the wall receptacle you intend to use will not accept a three-prong plug, or if you are not sure the outlet is adequately grounded or protected by a fuse or circuit breaker, have a qualified electrician install the proper oulet according to the National Electric Code and applicable local code.

• BEFORE INSTALLATION

Test Run Unit : Plug unit into proper power supply outlet.

Refer to operating instructions in this manual for comfortable living. Check all controls for correct operation, then unplug unit.

Determine Correct Mounting procedure-Refer to Window Installation or Through the Wall Installation.

WARNING :

Moving parts can cause personal injury. Be careful when test-running unit. Do not operate unit with front grille removed .

Be sure to use an exclusive power source.

Contact service man for replacement of power cord.

4

Daewoo DWC-073C, DWC-094C, DWC-072C, DWC-092C, DWC-051C User Manual

• Step 1 - Prepare Components For Installation

Parts for installation are as follows;

Sill Bracket (2 pieces)

Window Kit Left side (Frame ‘L+Shutter) - (1 piece)

Window Kit Right side (Frame ‘R+Shutter) - (1 piece)

Sash Bracket (1 piece)

Frame Guide Lower - (2 pieces)

Levelling Screw (Machine M8x45) - (2 pieces)

11/4 inch Screw (M5x30) - (4 pieces)

5/8 inch Screw - (M4x16) - (8 pieces)

1/4 inch Screw (M4x6) - (8 pieces)

Window Seal A, B (2 pieces)

• SCREW TYPE

Type A Type B Type C Type D

SHAPE

SPEC

M8 x 45

M5 x 30

M4 x 16

M4 x 6

Q'TY

2

4

8

8

 

Sash Bracket

 

 

 

(1 piece)

Window

Window Seal A (1 piece)

 

 

 

 

Shutter

 

 

 

(2 pieces)

 

Sill Bracket (2 pieces)

Frame Guide Lower

 

Window Seal B (1 piece)

 

 

 

(2 pieces)

 

 

 

 

Window kit Frame

Window kit Frame

 

 

Left side (1 piece)

Right side (1 piece)

• Step 2 - Prepare Window For Installation

1.Inspect window track, sash and sill to be sure they are strong enough to hold an air conditioner.

2.Measure width between window frame to be sure instant mount will fit in the window. Instant mount models are designed for Windows 24 inch (610mm) to 36 inch (914mm) wide.

3.Mark the center of Window sill with pencil.

4.Insert Screws (Type A) into the sill bracket.

5.Attach Sill bracket to window sill using two Screws (Type B) by each bracket. The outside edge of window bracket should be 9.4 inch (240mm) from center line.

6.Adjust Screw (Type A) so that Sill Bracket have a slight tilt by using carpenter's level meter.

Screw Type B

SILL

SASH

SILL BRACKET

600mm480mm

30240mm

Screw Type A

720~9610~9154mm

• Step 3 - Preparation of Chassis

1. Pull the Air-filter out of the Front Grille.

2. Loosen screw which fasten Front Grille with driver.

3. Pull knobs out of the control.

(when the knobs are too tight to release, leave them.)

5

Loading...