MDU14
QUAD, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU14)
data 3 ® delay
devices, inc.
FEATURES |
PACKAGES |
∙Four independent delay lines
∙Fits 24-pin (400mil) DIP socket
∙Auto-insertable
∙Input & outputs fully 100K-ECL interfaced & buffered
MDU14-xx DIP
MDU14-xxM Military DIP
GND |
1 |
24 |
I1 |
O1 |
3 |
22 |
I2 |
O2 |
5 |
20 |
I3 |
GND |
6 |
19 |
GND |
GND |
7 |
18 |
VEE |
O3 |
9 |
16 |
I4 |
O4 |
11 |
|
|
|
|
13 |
GND |
GND |
1 |
24 |
I1 |
N/C |
2 |
23 |
N/C |
O1 |
3 |
22 |
I2 |
N/C |
4 |
21 |
N/C |
O2 |
5 |
20 |
I3 |
GND |
6 |
19 |
GND |
GND |
7 |
18 |
VEE |
N/C |
8 |
17 |
N/C |
O3 |
9 |
16 |
I4 |
N/C |
10 |
15 |
N/C |
O4 |
11 |
14 |
N/C |
N/C |
12 |
13 |
GND |
DDU14-xxC4 |
|
SMD |
|
DDU14-xxMC4 |
Mil SMD |
FUNCTIONAL DESCRIPTION
The MDU14-series device is a 4-in-1 digitally buffered delay line. The signal inputs (I1-I4) are reproduced at the outputs (O1-O4), shifted in time by an amount determined by the device dash number (See Table). The delay lines function completely independently of each other.
PIN DESCRIPTIONS
I1-I4 Signal Inputs
O1-O4 Signal Outputs
VEE -5 Volts
GND Ground
SERIES SPECIFICATIONS
∙Minimum input pulse width: 40% of total delay
∙Output rise time: 2ns typical
∙Supply voltage: -5VDC ± 5%
∙Power dissipation: 500mw typical (no load)
∙Operating temperature: 0° to 85° C
∙Temp. coefficient of total delay: 100 PPM/°C
O1 |
O2 |
O3 |
O4 |
100% 100% 100% 100%
VCC |
I1 |
I2 |
I3 |
I4 |
GND |
Functional block diagram
©1997 Data Delay Devices
DASH NUMBER SPECIFICATIONS
Part |
Total |
|
Number |
Delay (ns) |
|
MDU14-2 |
2.0 |
± 1.0 |
|
||
MDU14-2.5 |
2.5 |
± 1.0 |
|
||
MDU14-3 |
3.0 |
± 1.0 |
|
||
MDU14-4 |
4.0 |
± 1.0 |
|
||
MDU14-5 |
5.0 |
± 1.0 |
|
||
MDU14-6 |
6.0 |
± 1.0 |
|
||
MDU14-7 |
7.0 |
± 1.0 |
|
||
MDU14-8 |
8.0 |
± 1.0 |
|
||
MDU14-9 |
9.0 |
± 1.0 |
|
||
MDU14-10 |
10.0 |
± 1.0 |
|
||
MDU14-12.5 |
12.5 |
± 1.0 |
|
||
MDU14-15 |
15.0 |
± 1.0 |
|
||
MDU14-20 |
20.0 |
± 1.0 |
|
||
MDU14-25 |
25.0 |
± 1.2 |
|
NOTE: Any dash number between 2 and 25 not shown is also available.
Doc #97042 |
DATA DELAY DEVICES, INC. |
1 |
12/15/97 |
3 Mt. Prospect Ave. Clifton, NJ 07013 |
MDU14
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The MDU14 tolerances are guaranteed for input pulse widths and periods greater than those specified in the test conditions. Although the device will function properly for pulse widths as small as 40% of the total delay and periods as small as 80% of the total delay (for a symmetric input), the delays may deviate from their values at low frequency. However, for a given input condition, the deviation will be repeatable from pulse to pulse. Contact technical support at Data
Delay Devices if your application requires device testing at a specific input condition.
POWER SUPPLY BYPASSING
The MDU14 relies on a stable power supply to produce repeatable delays within the stated tolerances. A 0.1uf capacitor from VEE to GND, located as close as possible to the VEE pin, is recommended. A wide VEE trace and a clean ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER |
SYMBOL |
MIN |
MAX |
UNITS |
NOTES |
DC Supply Voltage |
VEE |
-7.0 |
0.3 |
V |
|
Input Pin Voltage |
VIN |
VEE - 0.3 |
0.3 |
V |
|
Storage Temperature |
TSTRG |
-55 |
150 |
C |
|
Lead Temperature |
TLEAD |
|
300 |
C |
10 sec |
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 85C)
PARAMETER |
SYMBOL |
MIN |
TYP |
MAX |
UNITS |
NOTES |
High Level Output Voltage |
VOH |
-1.025 |
|
-0.880 |
V |
VIH = MAX,50Ω to -2V |
Low Level Output Voltage |
VOL |
-1.810 |
|
-1.620 |
V |
VIL = MIN, 50Ω to -2V |
High Level Input Voltage |
VIH |
-1.165 |
|
-0.880 |
V |
|
Low Level Input Voltage |
VIL |
-1.810 |
|
-1.475 |
V |
|
High Level Input Current |
IIH |
|
|
340 |
μA |
VIH = MAX |
Low Level Input Current |
IIL |
0.5 |
|
|
μA |
VIL = MIN |
Doc #97042 |
DATA DELAY DEVICES, INC. |
2 |
12/15/97 |
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com |