Crown MA3600VZ User Manual

5 (1)

Macro-Tech Series

Operation Manual

MA-3600VZ

Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000.

This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance.

Note: The information provided in this manual was deemed accurate as of the publication date. However, updates to this information may have occurred. To obtain the latest version of this manual, please visit the Crown website at www.crownaudio.com.

Trademark Notice: PIP and IQwic are trademarks, and Amcron, Crown, Crown Audio, Macro-Tech, IOC, IQ System, VZ and ODEP are registered trademarks of Crown International. Other trademarks are the property of their respective owners.

Some models may be exported under the name Amcron.®

©2007 by Crown Audio®, Inc. 1718 W. Mishawaka Rd., Elkhart, Indiana 46517-9439 U.S.A. Telephone: 574-294-8000

125113-10 12/07

Macro-Tech MA-3600VZ Power Amplifier

Important Safety Instructions

Wichtige Sicherheitsinstruktionen

Importantes Instructions de Sécurité

Instrucciones de Seguridad Importantes

IMPORTANT

1)Read these instructions.

2)Keep these instructions.

3)Heed all warnings.

4)Follow all instructions.

5)Do not use this apparatus near water.

6)Clean only with a dry cloth.

7)Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8)Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9)Do not defeat the safety purpose of the polarized or groundingtype plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10)Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11)Only use attachments/accessories specified by the manufacturer.

12)Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13)Unplug this apparatus during lightning storms or when unused for long periods of time.

14)Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15)Use the mains plug to disconnect the apparatus from the mains.

16)WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.

17)DO NOT EXPOSE THIS EQUIPMENT TO DRIPPING OR SPLASHING AND ENSURE THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, ARE PLACED ON THE EQUIPMENT.

18)THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE.

TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

À PRÉVENIR LE CHOC ÉLECTRIQUE N’ENLEVEZ PAS LES COUVERCLES. IL N’Y A PAS DES PARTIES SERVICEABLE À L’INTÉRIEUR. TOUS REPARATIONS DOIT ETRE FAIRE PAR PERSONNEL QUALIFIÉ SEULMENT.

PARA PREVENIR UN CHOQUE ELÉCTRICO, NO RETIRE LAS CUBIERTAS SUPERIOR O INFERIOR. NO EXISTEN PARTES QUE PUEDAN SER REPARADAS POR EL USUARIO AL INTERIOR. REMITA EL SERVICICO AL PERSONAL TÉCHNICAL CALIFICADO.

TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE AC MAINS, DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE AC RECEPTACLE. THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE.

POUR DÉMONTER COMPLÈTEMENT L'ÉQUIPEMENT DE L'ALIMENTATION GÉNÉRALE, DÉMONTER LE CÂBLE D'ALIMENTATION DE SON RÉCEPTACLE. LA PRISE D'ALIMENTATION RESTERA AISÉMENT FONCTIONNELLE.

PARA DESCONECTAR COMPLETAMENTE EL EQUIPO DEL SUMINSTRO ELECTRICO, DESCONECTE EL CABLE DE ALIMENTACION DE LA TOMA DE CA. LAS PATAS DEL CONECTOR DEL CABLE DE ALIMENTACIÓN DEBERAN MANTENERSE EN BUEN ESTADO.

WATCH FOR THESE SYMBOLS:

The lightning bolt triangle is used to alert the user to the risk of electric shock.

The exclamation point triangle is used to alert the user to important operating or maintenance instructions.

REGARDEZ CES SYMBOLES

La triangle avec le sigle ‘’foudre’’ est employée pour alerter l'utilisateur au risque de décharge électrique. Le triangle avec un point d'exclamation est employée pour alerter l'utilisateur d’instruction importantes pour lors opérations de maintenance.

ATENCION CON ESTOS SÍMBOLOS

El triángulo con el símbolo de rayo eléctrico es usado para alertar al usuario de el riesgo de un choque eléctrico.

El triángulo con el signo de admiración es usado para alertar al usuario de instrucciones importantes de operación o mantenimiento.

Macro-Tech 3600VZ requires Class 1 output wiring. Macro-Tech 3600VZ exige des câbles de sortie de classe 1 Macro-Tech 3600VZ erfordert Klasse die 1 Produktionsverdrahtung.

Macro-Tech 3600VZ requiere de un cableado de salida Clase 1.

MAGNETIC FIELD

CAUTION! Do not locate sensitive high-gain equipment such as preamplifiers or tape decks directly above or below the unit. Because this amplifier has a high power density, it has a strong magnetic field which can induce hum into unshielded devices that are located nearby. The field is strongest just above and below the unit.

If an equipment rack is used, we recommend locating the amplifier(s) in the bottom of the rack and the preamplifier or other sensitive equipment at the top.

FCC COMPLIANCE NOTICE

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

page 2

Operation Manual

Macro-Tech MA-3600VZ Power Amplifier

 

Crown International, Inc.

DECLARATION of CONFORMITY

TCF Technical Certificate No: P4300CRI1.IWS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Construction File Route

 

 

 

Issued By: Crown International, Inc.

 

FOR COMPLIANCE QUESTIONS ONLY: Sue Whitfield

 

 

 

1718 W. Mishawaka Road

 

 

574-294-8289

 

 

 

Elkhart, Indiana 46517 U.S.A.

 

 

swhitfield@crownintl.com

 

 

 

 

 

 

 

 

 

 

Competent Body’s Name and Address:

 

 

European Representative's Name and Address:

 

Technology International (Europe) Limited

 

 

David J. Budge

 

 

41-42 Shrivenham Hundred Business Park,

 

 

10 Harvest Close

 

 

Shrivenham, Swindon, Wilts, SN6 8TZ

 

 

Yateley

 

 

 

 

 

 

 

 

GU46 6YS

 

 

Equipment Type: Commercial Audio Power Amplifier

 

 

 

 

 

Family Name: Macro-Tech Series

 

 

 

 

 

Model Names: Macro-Tech 3600VZ

 

 

 

 

 

EMC Standards:

 

 

 

 

 

 

 

EN 55103-1:1995 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 1: Emissions

 

 

EN 55103-1:1995 Magnetic Field Emissions-Annex A @ 10 cm and 1 M

 

 

 

 

EN 61000-3-2:1995+A14:2000 Limits for Harmonic Current Emissions (equipment input current 16A per phase)

 

 

 

EN 61000-3-3:1995 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems Rated Current

16A

 

 

 

EN 55022:1992 + A1: 1995 & A2:1997 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE: Radiated, Class B Limits; Conducted, Class B

 

 

 

EN 55103-2:1996 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 2: Immunity

 

 

EN 61000-4-2:1995 Electrostatic Discharge Immunity (Environment E2-Criteria B, 4k V Contact, 8k V Air Discharge)

 

 

 

EN 61000-4-3:1996 Radiated, Radio-Frequency, Electromagnetic Immunity (Environment E2, criteria A)

 

 

 

 

EN 61000-4-4:1995 Electrical Fast Transient/Burst Immunity (Criteria B)

 

 

 

 

EN 61000-4-5:1995 Surge Immunity (Criteria B)

 

 

 

 

 

EN 61000-4-6:1996 Immunity to Conducted Disturbances Induced by Radio-Frequency Fields (Criteria A)

 

 

 

 

EN 61000-4-11:1994 Voltage Dips, Short Interruptions and Voltage Variation

 

 

 

 

Safety Standard:

 

 

 

 

 

 

 

EN 60065: 1998 Safety Requirements - Audio Video and Similar Electronic Apparatus

 

 

 

 

I certify that the product identified above conforms to the requirements of the EMC Council Directive 89/336/EEC as amended by 92/31/EEC, and the Low Voltage Directive 73/23/EES as amended by 93/68/EEC.

 

 

Signed

 

 

 

 

 

 

 

 

 

 

Larry Coburn

 

 

Date of Issue: March 28, 2000

 

 

Title: Senior Vice President of Manufacturing

 

 

 

 

 

 

 

 

 

Operation Manual

DUE TO LINE CURRENT HARMONICS, WE RECOMMEND THAT YOU CONTACT YOUR SUPPLY AUTHORITY BEFORE CONNECTION.

 

 

page 3

Macro-Tech MA-3600VZ Power Amplifier

Table of Contents

Important Safety Instructions .....................................................................................

2

5 Advanced Features and Options .......................................

14

Declaration of Conformity ..........................................................................................

3

5.1 Protection Systems .........................................................................

14

1 Welcome ........................................................................

5

5.1.1 Output Device Emulation Protection (ODEP) ............................

14

1.1

Features .........................................................................................................

5

5.1.2 IOC (Input Output Comparator) ................................................

14

2 How to Use This Manual ......................................................

5

5.2 Circuit Designs .................................................................................

14

3 Setup .............................................................................

6

5.2.1 Grounded Bridge ......................................................................

14

3.1

Unpack Your Amplifier ...................................................................................

6

5.2.2 Variable Impedance (VZ) ..........................................................

14

3.2

Install Your Amplifier .....................................................................................

6

5.3 Options ............................................................................................

15

3.3

Ensure Proper Cooling .................................................................................

6

5.3.1 IQ-PIP-USP2 Adapter and PIP-Lite Module .............................

15

3.4

Choose Input Wire and Connectors ..............................................................

7

5.3.2 Input Sensitivity Switch ............................................................

15

3.5

Choose Output Wire and Connectors .............................................................

8

5.3.3 Input Ground Lift Switch ..........................................................

15

3.6

Wire Your System .........................................................................................

9

6 Specifications ............................................................

16

 

3.6.1 Stereo Mode ..........................................................................................

9

7 Troubleshooting ..........................................................

20

 

3.6.2 Bridge-Mono Mode ..............................................................................

9

8 Service ....................................................................

21

 

3.6.3 Parallel-Mono Mode .............................................................................

10

8.1 Worldwide Service .............................................................................

21

3.7

Connect to AC Mains .....................................................................................

11

8.2 US and Canada Service ......................................................................

21

3.8

Startup Procedure ..........................................................................................

11

8.2.1 Service at a US or Canada Service Center.................................

21

4 Operation ........................................................................

11

8.2.2 Factory Service .........................................................................

21

4.1

Precautions ....................................................................................................

11

8.2.3 Factory Service Shipping Instructions .......................................

21

4.2

Front Panel Controls and Indicators ..............................................................

12

9 Warranty .................................................................

22

4.3

Back Panel Controls and Connectors .............................................................

13

Crown Factory Service Information Form ........................................................

25

page 4

Operation Manual

Macro-Tech MA-3600VZ Power Amplifier

MA-3600VZ

*1 kHz

Power

2 ohm Dual (per ch.)

1,800W

4 ohm Dual (per ch.)

1,565W

8 ohm Dual (per ch.)

1,120W

4 ohm Bridge-Mono

3,505W

8 ohm Bridge-Mono

3,140W

*1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.1% THD.

1 Welcome

The Crown® Macro-Tech ® 3600VZ professional power amplifier features Crown’s patented Variable Impedance (VZ ® ) power supply. This power supply, along with advanced semiconductor technology, enables the Macro-Tech 3600VZ to pack more power into a mere 3½ inches of vertical rack space than ever before. Because it’s a Macro-Tech, you have the added benefit of PIP ™ compatibility for access to custom input modules and ODEP ® protection to keep the show going long after other amplifiers would fail.

Modern power amplifiers are sophisticated pieces of engineering capable of producing extremely high power levels. They must be treated with respect and correctly installed if they are to provide the many years of reliable service for which they were designed.

In addition, the MA-3600VZ amplifier includes a number of features which require some explanation before they can be used to their maximum advantage.

Please take the time to study this manual so that you can obtain the best possible service from your amplifier.

1.1 Features

Grounded Bridge design delivers large voltage swings without stressing outputtransistors, resulting in lower distortion and superior reliability.

Patented ODEP (Output Device Emulation Protection) circuitry compensates for overheating and overload to keep the amplifier working when others would fail.

IOC® (Input/Output Comparator) circuitry immediately alerts of any distortion exceeding 0.05%, providing dynamic proof of distortion-free performance.

Articulated VZ power supplies for each channel provide excellent crosstalk characteristics and the best power matching to your load.

2 How to Use This Manual

This manual provides you with the necessary information to safely and correctly setup and operate your amplifier. It does not cover every aspect of installation, setup or operation that might occur under every condition. For additional information, please consult Crown’s

Amplifier Application Guide (available online at www.crownaudio.com), Crown Tech Support, your system installer or retailer.

We strongly recommend you read all instructions, warnings and cautions contained in this manual. Also, for your protection, please send in your warranty registration card today. And save your bill of sale—it’s your official proof of purchase.

Operation Manual

page 5

Crown MA3600VZ User Manual

Macro-Tech MA-3600VZ Power Amplifier

3 Setup

3.1 Unpack Your Amplifier

Please unpack and inspect your amplifier for any damage that may have occurred during transit. If damage is found, notify the transportation company immediately. Only you can initiate a claim for shipping damage. Crown will be happy to help as needed. Save the shipping carton as evidence of damage for the shipper’s inspection.

We also recommend that you save all packing materials so you will have them if you ever need to transport the unit. Never ship the unit without the factory pack.YOU WILL NEED (not supplied):

• Input wiring cables

• Output wiring cables

Rack for mounting amplifier (or a stable surface for stacking)

WARNING: Before you start to set up your amplifier, make sure you read and observe the Important Safety Instructions found at the beginning of this manual.

3.2 Install Your Amplifier

CAUTION: Before you begin, make sure your amplifier is disconnected from the power source, with power switch in the “off” position and all level controls turned completely down (counterclockwise).

Use a standard 19-inch (48.3 cm) equipment rack. See Figure 3.1 for amplifier dimensions.

You may also stack amps without using a cabinet.

NOTE: When transporting, amplifiers should be supported at both front and back.

Figure 3.1 Dimensions

page 6

3.3 Ensure Proper Cooling

When using an equipment rack, mount units directly on top of each other. Close any open spaces in rack with blank panels. DO NOT block front or rear air vents. The side walls of the rack should be a minimum of two inches (5.1 cm) away from the amplifier sides, and the back of the rack should be a minimum of four inches (10.2 cm) from the amplifier back panel.

Figure 3.2 illustrates standard amplifier airflow.

Figure 3.2 Airflow

Operation Manual

Macro-Tech MA-3600VZ Power Amplifier

3 Setup

3.4 Choose Input Wire

Balanced Line

Unbalanced Line

and Connectors

 

 

Figure 3.3 shows connector pin assignments for balanced wiring, and Figure 3.4 shows connector pin assignments for unbalanced wiring.

NOTE: Custom wiring should only be performed by qualified personnel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3.3 Balanced Input

 

Figure 3.4 Unbalanced Input

 

 

 

 

 

 

 

 

 

Connector Wiring

 

Connector Wiring

Operation Manual

page 7

Macro-Tech MA-3600VZ Power Amplifier

3 Setup

3.5 Choose Output Wire and Connectors

Crown recommends using pre-built or professionally wired, high-quality, two-conductor, heavy gauge speaker wire and connectors. You may use banana connectors, terminal forks or bare wire for your output connectors (see Figure 3.5). To prevent the possibility of short-circuits, wrap or otherwise insulate exposed loudspeaker cable connectors.

Note: Binding post outputs on European models come with safety plugs installed to prevent European power-cord plugs from being inserted. The side entry positions for these connectors should therefore be used.

Using the guidelines below, select the appropriate size of wire based on the distance from amplifier to speaker.

Distance

Wire Size

up to 25 ft.

16 gauge

26-40 ft.

14 gauge

41-60 ft.

12 gauge

61-100 ft.

10 gauge

101-150 ft.

8 gauge

151-250 ft.

6 gauge

CAUTION: Never use shielded cable for output wiring.

OUTPUTS

CH-2 CH-1

Figure 3.5 Output Connector Wiring

(MA-3600VZ Has 4 Pairs of Posts. Only 2 Pairs Are Shown.)

page 8

Operation Manual

Macro-Tech MA-3600VZ Power Amplifier

3 Setup

3.6 Wire Your System

3.6.1 Stereo Mode

Typical input and output wiring is shown in Figure 3.6.

INPUTS: Connect input wiring for each channel. Refer to Section 3.4 for input connector pin assignments.

OUTPUTS: Maintain proper polarity (+/-) on output connectors.

Connect positive (+) speaker lead to Channel 1 positive binding post of amp; connect negative

(–) speaker lead to Channel 1 negative binding post of amp. Repeat for Channel 2. Refer to Section 3.5 for output connector pin assignments. Make sure the Mode switch set to the “Stereo” position when operating in Stereo mode.

3.6.2 Bridge-Mono Mode

Typical input and output wiring is shown in Figure 3.7.

INPUTS: Connect input wiring to Channel 1. Refer to Section 3.4 for input connector pin assignments.

OUTPUTS: Connect positive (+) speaker lead to Channel 1 positive binding post of amp; connect negative (–) speaker lead to Channel 2 positive binding post of amp. Do not use the negative binding posts when operating in Bridge-Mono mode. Refer to Section 3.5 for output connector pin assignments. Make sure the Mode switch is set to the “Bridge” position when operating in Bridge-Mono mode.

NOTE: Turn down (full CCW) the Channel 2 level control when operating in BridgeMono mode, as the Channel 1 level control works both channels.

Figure 3.6 System Wiring, Stereo Mode