Crestron FT2A-PWR-UN-1-C14 Installation Manual

Page 1
FT2A-PWR-UN-1-C14
AC Power Outlet Module for FT2 Series, Universal, C14 Inlet Installation Guide
Description
The Crestron® FT2A-PWR-UN-1-C14 module provides one universal ac power outlet for use with the FT2 series of FlipTop™ cable managment devices. The module may be used to power laptops and other ac-powered devices at the table.
The FT2A-PWR-UN-1-C14 module is suitable for use in the United States, Canada, Mexico, Europe, United Kingdom, Japan, Korea, Singapore, Saudi Arabia, Australia, New Zealand, China, and other countries or regions where Plug Types B, F, G, or I power outlets are used.
Additional Resources
Visit the product page on the Crestron website (www.crestron.com) for additional information and the latest rmware updates. Use a QR reader application on your mobile device to scan the QR image.
Overview
The FT2A-PWR-UN-1-C14 has the following specications:
• Each FT2A-PWR-UN-1-C14 module provides one universal ac power outlet that is rated for 10 A (total) at 100–240 Vac, 50/60 Hz.
• An IEC C-14 socket is provided on the bottom of each module, which is used to connect the module to a power source via an IEC power cord rated for 10 A or better (not included).
• One blank plate is provided with the FT2A-PWR-UN-1-C14 module for use with low-prole power cords. Refer to the note below.
Installation
Use the following procedure to install the FT2A-PWR-UN-1-C14 module into an FT2 series assembly.
If the FT2A-PWR-UN-1-C14 module is being installed as part of a new FT2 series FlipTop device installation, proceed to step 3 below.
Install the FT2A-PWR-UN-1-C14 Module
1. Remove the magnetic bezel from the FT2 series assembly by grasping the inside of the bezel and pulling it up and away rmly from the assembly until the magnetic hold is broken.
2. Unscrew and remove the two locking bars that secure the module row required for installation.
For example, if installing the FT2A-PWR-UN-1-C14 module in the front row of an
FT2-700 series FlipTop device, remove the front and center locking bars.
Locking bar
(center)
Locking bar
(rear)
FT2A-PWR-UN-1-C14
module
NOTE: If low-prole power cords are expected to be used with the FT2A-PWR-UN-1-C14 module, ensure that the provided blank plate is installed to the right of the module.
Low-prole power
cord must clear top
of FT2 series bezel
Blank plate
Locking bar
(front)
3. Connect an IEC power cord (rated for 10 A or better) to the IEC C-14 socket on the bottom of the FT2A-PWR-UN-1-C14 module.
FT2A-PWR-UN-1-C14 module (bottom view)
IEC C-14 socket
Each module is 1.97 x 1.97 in (50 x 50 mm) and occupies two empty module spaces in an FT2 series assembly.
Page 2
4. Orient the module so that it is facing toward the front of the FT2 series assembly as shown in the illustration below.
FT2A-PWR-UN-1-C14 module
IEC power cord
Retractable lid (located in rear of assembly)
FT2 series assembly (front)
Complete the Installation
1. Once all modules and plates are installed and level with their surroundings, place the removed locking bars back into position so that the screws attached to either side of each locking bar engage their screw holes in the FT2 series assembly.
2. Using a manual torque screwdriver set to its lowest possible setting, hand tighten the locking bar screws until the locking bars are secured to the assembly.
CAUTION: Do not overtighten the locking bar screws.
3. Hold the magnetic bezel over the FT2 series assembly so that the lid retraction button on the bezel is aligned with the front of the assembly.
4. Lower the bezel onto the assembly so that the lowered retractable lid ts inside the rear opening in the bezel and the magnets snap into place against the assembly. Refer to the illustration below.
Bezel opening for retractable lid
Retractable lid
Lid retraction button
5. Feed the IEC power cord attached to the module down through the appropriate module spaces in the FT2 series assembly.
6. Slide the module into the appropriate module spaces in the FT2 series assembly. Use the guide ribs on the front and rear of the module to help position the module in the assembly.
FT2A-PWR-UN-1-C14
module
As of the date of manufacture, the product has been tested and found to comply with specications for CE marking.
The product warranty may be found at www.crestron.com/legal/sales-terms-conditions-warranties.
The specic patents that cover Crestron products are listed at www.crestron.com/legal/patents.
Certain Crestron products contain open source software. For specic information, please visit
www.crestron.com/legal/open-source-software.
Crestron, the Crestron logo, and FlipTop are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2018 Crestron Electronics, Inc.
Crestron Electronics, Inc. Installation Guide - DOC. 8344A
15 Volvo Drive, Rockleigh, NJ 07647 (2052164) Tel: 888.CRESTRON 07.18 Fax: 201.767.7576 Specications subject to www.crestron.com change without notice.
Loading...