Creda Newera Profile and Profile Plus Panel Heaters

Installation and Operating Instructions

Wattage (W)

Model with

Model with controls

Model with no

Dimensions

controls white

silver

controls white

(mm)

 

500

NPP50 75-773001

NPP50S 75-773011

NP50 75-772901

442 x 430 x 80

 

 

 

 

 

1000

NPP100 75-773002

NPP100S 75-773012

NP100 75-772902

680 x 430 x 80

 

 

 

 

 

1500

NPP150 75-773003

NPP150S 75-773013

NP150 75-772903

680 x 430 x 80

 

 

 

 

 

2000

NPP200 75-773004

NPP200S 75-773014

NP200 75-772904

852 x 430 x 80

 

 

 

 

 

The Newera Profile panel heater range is designed for wall mounting on the wall brackets supplied. It should only be operated when in the upright position as shown in diagram C.

All models are protected against moisture ingress to IPX4 standard.

All models, except those with no controls, are fitted with a 7-day digital programmer.

Installation:

Before connecting the heater, check that the supply voltage is the same as that stated on the rating label.

When selecting the position for the heater to be installed, consideration should be given to ensure that there are no obstructions closer than the dimensions given in Diagram C. The bracket for the heater should be fitted in accordance with the method detailed in the associated diagrams. The heater must not be located below a socket outlet or connection box.

Care must be exercised when fitting the heater onto the bracket. Pressure should only be applied to the ends of the heater and not to the grille area.

The electrical installation must be carried out by a competent electrician and in accordance with the current Electrical Wiring Regulations (BS7671) and/or local regulations.

The heater is fitted with a length of flexible cable for connection to the fixed wiring of the premises via a suitable connection box positioned adjacent to the heater.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules.

WARNING – THIS APPLIANCE MUST BE EARTHED

WARNING – In order to avoid overheating, do not cover the heater.

Creda NPP100S 75-773012, NPP150 75-773003, NPP100 75-773002, NPP50 75-773001, NP200 75-772904 User Manual

Bathroom Installation

IMPORTANT – If the heater is installed in a room containing a bath or shower, it must be so installed that switches and other controls cannot be touched by a person using a bath or shower.

Wall Mounting

IMPORTANT – DO NOT locate the heater immediately below a fixed socket outlet or connection box. The wall bracket supplied with the appliance should be fitted using the screws and wall plugs provided. The heater should be positioned observing the minimum clearances around the heater (see diagram C).

For all heater sizes

The bracket has been designed to be used as a template for setting the wall fixing position. Refer to the diagrams below for dimensional details. To set the vertical minimum, the bracket should be positioned on the floor and the wall marked at the notches in the vertical members of the bracket. This marks the final position of the bottom of the bracket. When placing the heater on the bracket, firstly engage the heater on to the bottom hooks and then press the heater on to the catches. It is recommended to press the heater at the ends and not on the grille area.

500W Heater (refer to diagram A)

If the heater is required to be fitted towards an object/obstruction to the left then the bracket should be positioned against the floor and the object/obstruction and the wall marked along the right edge of the right upright. This is the final position of the left side of the left upright member of the bracket.

If the heater is required to be fitted towards an object/obstruction to the right then the bracket should be positioned against the floor and the object/obstruction and the wall marked along the left edge of the left upright. This is the final position of the right side of the right upright member of the bracket.

All other sizes of heaters (refer to diagram B)

If the heater is required to be fitted towards an object/obstruction to the left then the bracket should be positioned against the floor and the object/obstruction and the wall marked at notch ‘A’. This is the final position of the left side of the left upright member of the bracket.

If the heater is required to be fitted towards an object/obstruction to the right then the bracket should be positioned against the floor and the object/obstruction, and the wall marked at notch ‘B’. This is the final position of the right side of the right upright member of the bracket.

The bracket has also been designed to allow the use of a spirit level on the horizontal member for levelling during fitting.

Final bracket position

Loading...
+ 2 hidden pages