Craftsman Portable Generator Owner's Manual

5 (2)

Portable Generator

Operator’s Manual

This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators).

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC

JEFFERSON, WISCONSIN, U.S.A.

Manual No. 206883GS Revision - (04/28/2008)

Thank you for purchasing this quality-built Briggs & Stratton generator. We are pleased that you’ve placed your confidence in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs & Stratton generator will provide many years of dependable service.

This manual contains safety information to make you aware of the hazards and risks associated with generators and how to avoid them. This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting, appliances, tools and motor loads, and is not intended for any other purpose. It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment. Save these instructions for future reference.

This generator requires final assembly before use. Refer to the Assembly section of this manual for instructions on final assembly procedures. Follow the instructions completely.

Where to Find Us

You never have to look far to find Briggs & Stratton support and service for your generator. Consult your Yellow Pages. There are over 30,000 Briggs & Stratton authorized service dealers worldwide who provide quality service. You can also contact Briggs & Stratton Customer Service by phone at (800) 743-4115, or on the Internet at BRIGGSandSTRATTON.COM.

Generator

Model Number

Revision

Serial Number

Engine

Model Number

Type Number

Code Number

Date Purchased

Briggs & Stratton Power Products Group, LLC

900 North Parkway

Jefferson, WI 53549

Copyright © 2008 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power Products Group, LLC.

2

BRIGGSandSTRATTON.COM

Table of Contents

Operator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Equipment Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Unpack Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Install Wheel Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Verify Engine Oil Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Add Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 System Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Connecting to a Building’s Electrical System. . . . . . . . . . . . . . . . . . . . . . . . 9 Generator Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Features and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Cord Sets and Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Generator Adapter Cord Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Starting the Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Connecting Electrical Loads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Stopping the Engine. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Don’t Overload Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Generator Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Engine Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Warranties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Emissions Control System Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Generator Owner Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Common Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Español

3

Operator Safety

Equipment Description

Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved.

The generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads. The generator’s revolving field is driven at about 3,600 rpm by a single-cylinder engine.

NOTICE

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

DO NOT exceed the generator’s wattage/amperage capacity. See

Don’t Overload Generator in the Operation section.

Every effort has been made to ensure that the information in this manual is both accurate and current. However, the manufacturer reserves the right to change, alter or otherwise improve the generator and this documentation at any time without prior notice.

The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency and the California Air Resources Board.

Safety Rules

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

The safety alert symbol () is used with a signal word (DANGER, WARNING, CAUTION), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. NOTICE indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and the tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work method or operating technique that the manufacturer does not specifically recommend, you must satisfy yourself that it is safe for you and others. You must also make sure that the procedure, work method or operating technique that you choose does not render the generator unsafe.

Hazard Symbols and Meanings

A

B

C

D

E

F

G

H

J

A - Explosion

F - Hot Surface

 

B - Fire

G - Flying Objects

 

C - Electric Shock

H - Moving Parts

 

D - Toxic Fumes

J - Read Manual

 

E - Kickback

 

 

 

WARNING

 

Running engine gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause headache, fatigue, dizziness, vomiting, confusion, seizures, nausea, fainting or death.

Operate generator ONLY outdoors.

Install a battery operated carbon monoxide alarm near the bedrooms.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes, or other openings.

DO NOT start or run engine indoors or in an enclosed area, (even if windows and doors are open), including the generator compartment of a recreational vehicle (RV).

4

BRIGGSandSTRATTON.COM

WARNING

Certain components in this product and related accessories contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. Wash hands after handling.

WARNING

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

WARNING

Generator produces hazardous voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Starter cord kickback (rapid retraction) can result in bodily injury. Kickback will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises, or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING OR DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

If fuel spills, wait until it evaporates before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap, and air cleaner are in place.

DO NOT crank engine with spark plug removed.

WHEN OPERATING EQUIPMENT

DO NOT tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers, or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/or property damage.

5

WARNING

Contact with muffler area can result in serious burns.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot parts and AVOID hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

WARNING

Starter and other rotating parts can entangle hands, hair, clothing, or accessories.

NEVER operate generator without protective housing or covers.

DO NOT wear loose clothing, jewelry or anything that may be caught in the starter or other rotating parts.

Tie up long hair and remove jewelry.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

NOTICE

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

DO NOT exceed the generator’s wattage/amperage capacity. See

Don’t Overload Generator in the Operation section.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

NOTICE

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or contact local service center.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

6

BRIGGSandSTRATTON.COM

Assembly

Read entire operator’s manual before you attempt to assemble or operate your new generator.

Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil level is verified.

If you have any problems with the assembly of your generator, please call the generator helpline at (800) 743-4115. If calling for assistance, please have the model, revision, and serial number from the identification label available. See generator Features and Controls for identification label location.

Unpack Generator

1.Set the carton on a rigid, flat surface.

2.Remove everything from carton except generator.

3.Open carton completely by cutting each corner from top to bottom.

4.Leave generator on carton to install wheel kit.

The generator is supplied with:

Operator’s manual

Adapter cord set

Three packets of fuel stabilizer

Wheels (2)

Axle

Support leg

Wheel kit hardware

Install Wheel Kit

Install

wheel kit as follows:

1.generator so that engine end is up.

2.axle (A) through both mounting brackets.

3.wheel (B) over axle.

NOTE: sure to install wheel with raised hub inboard.

4.a washer (C) on axle and then place an e-ring (D) groove.

CAUTION

E-rings can cause eye injury.

E-rings can spring back and become airborne when installing or removing.

wear eye protection when installing/removing e-rings.

5. Install e-ring with pliers, squeezing from top of e-ring of axle.

6.Repeat steps 3 through 5 to secure second wheel.

7.Return generator to normal operating position (resting wheels).

8.Remove handle (H) from generator frame by pushing in J) and pulling up on handle.

9.handle around as shown below and attach it to generator frame by pushing in pins on generator frame.

handle down until pins lock into holes on handle.

10.generator so that engine side is down.

11.holes in support leg (E) with holes in generator

12.Attach support leg using 2 capscrews (M8 x 20 mm) ( 2 hex nuts (G). Tighten with a 13 mm socket wrench and 13 mm wrench.

NOTE: Wheel kit is not intended for over-the-road use.

You will need the following tools to install these components:

13 mm wrench

Socket wrench with a 13 mm socket

Pliers

Safety glasses

13. Return generator to normal operating position (resting wheels and support leg).

NOTE: the handle around on the generator frame for purposes ONLY.

H

J

C

A

F B

E

D

7

Verify Engine Oil Level

The generator engine is shipped from the factory filled with oil (API SJ or higher 10W-30). This allows for generator operation in the widest range of temperature and climate conditions. Before starting the engine, check oil level and ensure that engine is serviced as described in Maintenance.

NOTE: See Oil in the Maintenance section to review oil recomendations. Verify provided oil in engine is the correct viscosity for current ambient temperature.

NOTICE

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

Refer to Maintenance for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

Add Fuel

Fuel must meet these requirements:

Clean, fresh, unleaded gasoline.

A minimum of 87 octane/87 AKI (91 RON). High altitude use, see High Altitude.

Gasoline with up to 10% ethanol (gasohol) or up to 15% MTBE (methyl tertiary butyl ether) is acceptable.

NOTICE

Avoid generator damage.

Failure to follow Operator’s Manual for fuel recommendations voids warranty.

DO NOT use unapproved gasoline such as E85.

DO NOT mix oil in gasoline.

DO NOT modify engine to run on alternate fuels.

To protect the fuel system from gum formation, mix in a fuel stabilizer when adding fuel. See Storage. All fuel is not the same. If you experience starting or performance problems after using fuel, switch to a different fuel provider or change brands. This engine is certified to operate on gasoline. The emission control system for this engine is EM (Engine Modifications).

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

If fuel spills, wait until it evaporates before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

1.

Clean area around fuel fill

remove cap.

2.

Slowly add unleaded

) to fuel tank (B). Be

 

careful not to overfill.

1.5" (4 cm) of tank

 

space (C) for fuel

 

B

C

A

3.Install fuel cap and let any spilled fuel evaporate before starting engine.

High Altitude

At altitudes over 5,000 feet (1524 meters), a minimum 85 octane / 85 AKI (89 RON) gasoline is acceptable. To remain emissions compliant, high altitude adjustment is required. Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. See an authorized dealer for high

altitude adjustment information. Operation of the engine at altitudes below 2,500 feet (762 meters) with the high altitude kit is not recommended.

8

BRIGGSandSTRATTON.COM

Craftsman Portable Generator Owner's Manual

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction:

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes.

WARNING

Generator produces hazardous voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

Generator Location

Clearances and Air Movement

WARNING

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

Keep at least 5 ft. (1.5 m) clearance on all sides of generator including overhead.

Place generator outdoors in an area that will not accumulate deadly exhaust gas. DO NOT place generator where exhaust gas (A) could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes, or other openings that can allow exhaust gas to collect in a confined area. Prevailing winds and air currents should be taken into consideration when positioning generator.

A

9

Features and Controls

Read this Operator’s Manual and safety rules before operating your generator.

Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

A

P

K

H

A - Fuel Tank — Capacity of seven (7) U.S. gallons.

B - Fuel Valve — Used to turn fuel supply on and off to engine.

C - Choke Lever — Used when starting a cold engine.

D - Air Cleaner — Protects engine by filtering dust and debris out of intake air.

E - Recoil Starter — Used to start the engine.

F - Engine Rocker Switch — Set this switch to "On" before using recoil starter. Set switch to "Off" to switch off engine.

G - Oil Fill Cap — Check and add engine oil here. H - Oil Drain Plug — Drain engine oil here.

J - Grounding Fastener — Consult your local agency having jurisdiction for grounding requirements in your area.

K - Identification Label — Provides model, revision and serial number of generator. Please have these readily available when calling for assistance.

L - Rocker Switch Circuit Breaker — The receptacles are provided with a rocker switch circuit breaker to protect the generator against electrical overload.

M - 120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads.

N - Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.

P - 120 Volt AC, 20 Amp, Duplex Receptacles — May be used to supply electrical power for the operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads.

10

BRIGGSandSTRATTON.COM

Cord Sets and Receptacles

Use only high quality, well-insulated, grounded extension cords with the generator’s 120 Volt duplex receptacle. Inspect extension cords before each use.

Check the ratings of all extension cords before you use them. Extension cord sets used should be rated for 125 Volt AC loads at 20 Amps or greater for most electrical devices. Some devices, however, may not require this type of extension cord. Check the operator’s manuals of those devices for the manufacturer’s recommendations.

Keep extension cords as short as possible to minimize voltage drop.

WARNING

Overloaded electrical cords can overheat, arc, and burn resulting in death, bodily injury, and/or property damage.

ONLY use cords rated for your loads.

Follow all safeties on electrical cords.

120/240 Volt AC, 30 Amp, Locking Receptacle

Use a NEMA L14-30 plug with this receptacle. Connect a 4-wire cord set rated for 250 Volt AC loads at 30 Amps (or greater). You can use the same 4-wire cord if you plan to run a 120 Volt load.

4-Wire Cord Set

240V

120V 120V

W (Neutral)

Y (Hot)

X (Hot)

NEMA L14-30

Ground (Green)

This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 5,500 watts of power (5.5 kW) at

22.9 Amps for 240 Volts or two independent 120 Volt loads at 22.9 Amps each. The outlet is protected by a two pole rocker switch circuit breaker.

NOTICE

Receptacles may be marked with rating value greater than generator output capacity.

NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.

DO NOT overload the generator. See Don’t Overload Generator.

120 Volt AC, 20 Amp, Duplex Receptacles

The duplex receptacles are protected against overload by a two pole rocker switch circuit breaker.

Use each receptacle to operate 120 Volt AC, single-phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater). Inspect cord sets before each use.

Generator Adapter Cord Set

The generator comes with a 25' generator adapter cord set designed to provide two sets of 120 Volt, 20 Amp outlets from one 120 Volt, 20 Amp duplex receptacle.

The maximum load on each outlet is 20 Amps. The maximum total load on both black wire outlets or white stripe wire outlets is 20 Amps.

NOTE: Follow all safety precautions when connecting any extension cord or device to the generator.

11

Operation

Starting the Engine

Disconnect all electrical loads from the generator. Use the following start instructions (see Features and Controls for location of controls described below):

1. Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate the unit on a level surface will cause the unit not to start or shut down during operation.

2.Turn the fuel valve to the “On” position. The fuel valve handle should be vertical (pointing toward the ground) for fuel to flow.

3. Push choke lever to “Choke” position ().

4. Push engine rocker switch to “On”.

5.Grasp recoil handle and pull slowly until slight resistance is felt. Then pull rapidly one time only to start engine.

If engine starts, proceed to step 7.

If engine fails to start, proceed to step 6.

WARNING

Starter cord kickback (rapid retraction) can result in bodily injury. Kickback will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises, or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

6.Move choke lever to “Half” choke position, and pull recoil handle twice.

• If engine fails to start, repeat steps 5 thru 7.

7.Slowly move choke lever to “Run” position (). If engine falters, move choke lever to “Half” choke

position until engine runs smoothly, and then to “Run” position ().

IMPORTANT: If engine floods, place choke lever in “Run” position () and crank until engine starts.

NOTE: If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase. This unit may be equipped with a low oil protection device. If so, oil must be at proper level for engine to start.

WARNING

Contact with muffler area can result in serious burns.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot parts and AVOID hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

12

BRIGGSandSTRATTON.COM

Connecting Electrical Loads

1.Let engine stabilize and warm up for a few minutes after starting.

2.Ensure circuit breaker on control panel is in “On” position.

3.Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.

IMPORTANT: When plugging into the 120 Volt receptacles, plug items to be powered in sequence as shown below.

1

3

2

NOTE:

DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles

DO NOT connect 3-phase loads to the generator.

DO NOT connect 50 Hz loads to the generator.

DO NOT OVERLOAD THE GENERATOR. See Don’t Overload Generator.

NOTICE

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

• DO NOT exceed

generator’s wattage/amperage capacity. See

Don’t Overload Generator in the Operation section.

• Start generator

let engine stabilize before connecting

electrical loads

 

Connect electrical loads in OFF position, then turn ON for operation.

• Turn electrical

OFF and disconnect from generator before

stopping generator

 

Stopping the Engine

1.Turn OFF and unplug all electrical loads from generator panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON.

2.Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator.

3.Push engine rocker switch to “Off” position.

WARNING

Backfire, fire or engine damage could occur.

DO NOT stop engine by moving choke control to “Choke” position ().

4.Move fuel valve to “Off” position.

13

Don’t Overload Generator

Capacity

You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps:

1.Select the items you will power at the same time.

2.Total the rated (running) watts of these items. This is the amount of power your generator must produce to keep your items running. See Wattage Reference Guide.

3.Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.

Example:

Tool or Appliance

Watts

 

(Starting) Watts

Window Air

1200

 

1800

Conditioner

 

 

 

Refrigerator

800

 

1600

 

 

 

 

Deep Freezer

500

 

500

 

 

 

 

Television

500

 

 

 

 

 

Light (75 Watts)

75

 

 

 

 

 

 

3075 Total

 

1800 Highest

 

Running Watts

 

Surge Watts

Total Rated (Running) Watts

= 3075

Highest Additional Surge Watts

= 1800

Total Generator Output Required

= 4875

Power Management

To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator. There should be nothing connected to the generator outlets before starting its engine. The correct and safe way to manage generator power is to sequentially add loads as follows:

1.With nothing connected to the generator, start the engine as described in this manual.

2.Plug in and turn on the first load, preferably the largest load you have.

3.Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).

4.Plug in and turn on the next load.

5.Again, permit the generator to stabilize.

6.Repeat steps 4 and 5 for each additional load.

NEVER add more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as described above.

 

Rated*

Additional

Tool or Appliance

(Running)

Surge (Starting)

 

Watts

Watts

 

 

 

Essentials

 

 

 

 

 

Light Bulb - 75 watt

75

-

Deep Freezer

500

500

Sump Pump

800

1200

 

 

 

Refrigerator/Freezer - 18 Cu. Ft.

800

1600

Water Well Pump - 1/3 HP

1000

2000

 

 

 

Heating/Cooling

 

 

 

 

 

Window AC - 10,000 BTU

1200

1800

Window Fan

300

600

Furnace Fan Blower - 1/2 HP

800

1300

 

 

 

Kitchen

 

 

 

 

 

Microwave Oven - 1000 Watt

1000

-

Coffee Maker

1500

-

 

 

 

Electric Stove - Single Element

1500

-

 

 

 

Hot Plate

2500

-

Family Room

 

 

DVD/CD Player

100

-

 

 

 

VCR

100

-

 

 

 

Stereo Receiver

450

-

Color Television - 27”

500

-

 

 

 

Personal Computer w/17” monitor

800

-

 

 

 

Other

 

 

 

 

 

Security System

180

-

AM/FM Clock Radio

300

-

 

 

 

Garage Door Opener - 1/2 HP

480

520

 

 

 

Electric Water Heater - 40 Gallon

4000

-

 

 

 

DIY/Job Site

 

 

Quartz Halogen Work Light

1000

-

 

 

 

Airless Sprayer - 1/3 HP

600

1200

 

 

 

Reciprocating Saw

960

960

Electric Drill - 1/2 HP

1000

1000

 

 

 

Circular Saw - 7 1/4”

1500

1500

 

 

 

Miter Saw - 10”

1800

1800

Table Planer - 6”

1800

1800

Table Saw/Radial Arm Saw - 10”

2000

2000

 

 

 

Air Compressor - 1-1/2 HP

2500

2500

 

 

 

* Wattages listed are approximate only. Check tool or appliance for actual wattage.

14

BRIGGSandSTRATTON.COM

Maintenance

Maintenance Schedule

Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below.

First 5 Hours

• Change engine oil

Every 8 Hours or Daily

Clean debris

Check engine oil level

Every 25 Hours or Yearly

• Service engine air cleaner1

Every 50 Hours or Yearly

• Change engine oil1

Every 100 Hours or Yearly

Service spark plug

Service spark arrester

Clean cooling system1

Every 250 Hours or Yearly

• Check valve clearance

1 Service more often under dirty or dusty conditions.

General Recommendations

Regular maintenance will improve the performance and extend the life of the generator. See any authorized dealer for service.

The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.

Some adjustments will need to be made periodically to properly maintain your generator.

All service and adjustments should be made at least once each season. Follow the requirements in the Maintenance Schedule chart above.

NOTE: Once a year you should clean or replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.

Emissions Control

Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual.

However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.

NOTE: DO NOT use water or other liquids to clean generator. Liquids can enter engine fuel system, causing poor performance and/or failure to occur. In addition, if liquid enters generator through cooling air slots, some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation. Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

Cleaning

Daily or before use, look around and underneath the generator for signs of oil or fuel leaks. Clean accumulated debris from inside and outside the generator. Keep the linkage, spring and other engine controls clean. Keep the area around and behind the muffler free from any combustible debris. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed.

Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris:

• Use a damp cloth to wipe exterior surfaces clean.

NOTICE

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

15