Cooper Lighting SA6150, SA6101, SA6050, SA6001, SA6002 User Manual

...
0 (0)

TM

Epic/Wall Mounted

INSTALLATION INSTRUCTIONS

Fixtures

Sheet 1 of 4

 

 

10/18/05 IMI-658

IMPORTANT: Read carefully before installing fixture. Retain for future reference.

General: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise.

Safety: This fixture must be wired in accordance with the national electrical code and applicable local codes and ordinance. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section. All work should be done by a qualified electrician.

WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.

ARM INSTALLATION

Bishop Arm (SA6001-SA6002, SA6050-SA6051, SA6101-SA6102 & SA6150-SA6151)

See Figure 1.

1. Secure arm mount flush with wall using 3/8” hardware supplied by others.

2. Remove wireway cover screws and wireway cover.

3. Mount arm to arm mount positioning service leads in wireway. Insert and tighten four screws to 80 in/lbs.

4. Pull fixture leads through arm.

5. Align locating pin and socket when raising fixture to arm. See Figure 2.

6. Insert and tighten 4 fixture screws with Teflon washers, provided in polybag, to 80 in/lbs.

7. Connect fixture leads to service leads in wireway.

8. Resecure wireway cover with wireway cover screws tightened to 50 in/lbs.

Traditional Arm (SA6003-SA6004, SA6052-SA6053, SA6103-

SA6104 & SA6152-SA6153)

See Figure 3.

1.Secure arm mount flush with wall using 3/8” hardware supplied by others.

2.Remove wireway cover screw and wireway cover.

3.Mount arm to arm mount positioning service leads in wireway. Insert and tighten set screw to 80 in/lbs.

4.Pull fixture leads through arm.

5.Align locating pin and socket when raising fixture to arm. See Figure 2.

6.Insert and tighten 4 fixture screws with Teflon washers, provided in polybag, to 80 in/lbs.

7.Connect fixture leads to service leads in wireway.

8.Resecure wireway cover with wireway cover screw tightened to 50 in/lbs.

Backplate Med

Bishop Wall

(4) 3/8-16 x 1-1/4 Button Head Cap Screws

(4) 3/8" Lag Bolts (supplied by others)

Wireway Cover

Wireway Cover

 

Srews (2)

Bishop Arm

Fixture Screws (4)

Teflon Washer (4)

Fig. 1

Modern Top

Aligning Pin

Aligning Socket

Fig. 2a

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-658 ADW051684

Cooper Lighting SA6150, SA6101, SA6050, SA6001, SA6002 User Manual

TM

Epic/Wall Mounted

INSTALLATION INSTRUCTIONS

Fixtures

Sheet 2 of 4

 

 

10/18/05 IMI-658

IMPORTANT: Read carefully before installing fixture. Retain for future reference.

FIXTURE MAINTENANCE

A. Relamping

Horizontally lamped

1. Loosen two door screws.

2. Lower door to tethered resting position. See Figure 4.

3.Install suitable lamp. Consult re-lamp label and lamp instructions for details. Do not overtighten.

4.Raise door and secure with screws.

Vertically lamped

1.Loosen and remove ring retaining screws globe retaining ring and globe. Components are not tethered.

See Figure 5. (closeup of lowered globe and ring)

2.Install suitable lamp. Consult re-lamp label and lamp instructions for details. Do not overtighten.

3.Reinstall ring retaining screws securing globe retaining ring and globe. In the case of type 3 refractive glass globe, use the mark on globe bottom for orientation.

B. Starter and Fuse Replacement (Where applicable)

Horizontally lamped

1.Loosen two door screws.

2.Lower door to tethered resting position. See Figure 4.

3.Loosen thumbscrew until rectangular washer can be rotated 90 degrees. See Figure 6.

4.Rotate reflector faceplate to release from screws using key hole slots.

5.Unplug optic quick-disconnect.

6.Remove two screws on ballast cover followed by ballast cover. See Figure 7.

7.For starter replacement, remove the plug-in starter from receptacle and replace.

For fuse replacement, unscrew fuse holder cap and replace fuse. Resecure fuse holder cap.

8.Resecure the ballast cover with the two screws.

9.Plug optic quick-disconnect and secure reflector by keyhole slots and thumbscrew.

10.Raise door and secure with screws.

Classical Top

Aligning Socket

Aligning Pin

Fig. 2b

Traditional Arm

Arm Mount

Mounting Hardware

 

Fixture Screws

(supplied by others)

Wireway Cover Screws

Teflon Washers

 

 

 

 

Wireway Cover

 

Fig. 3

Fig. 4a

Options

 

Flat Lens or Sag Lens

 

Door Screws

Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-658 ADW051684

Loading...