PARALUX V
388
COOPER LIGHTING - METALUX®
2P5GAX SERIES
1 ' |
x |
2 ' , |
1 ' x 4 ' , 2 ' x 2 ' , |
2 ' |
x |
4 ' , |
2 0 " x 2 4 " o r |
2 0 " x 4 8 " P a r a b o l i c 1 , 2 o r 3 L a m p
P a r a b o l i c L o u v e r
PA R A L U X V R E C E S S E D A I R S U P P LY P R E C I S I O N C U T- O F F T R O F F E R
•Equipped with energy saving ballast/complies with federal energy efficiency standards
•Computer designed, precision cell louver technology
•Louver designed to eliminate objectionable glare in the VDT screen
•Low iridescent louver minimizes iridescence
•Field convertible feature
•Floating louver/black reveal
•Efficient air handling options
•DLS Dimming Ballasts are available
•End plate grid-lock feature (1)
•For information on flanged fixture, including ceiling opening size, see Technical Section.
•UL/CUL Listed. Suitable for damp locations.
COOPER LIGHTING
D E S C R I P T I O N D I M E N S I O N S
The Paralux V series features a proprietary “Total Light Control System” that has been designed to eliminate glare reflections in VDT screens by suppressing high angle brightness. Meets today’s lighting standards. The luminaire incorporates a precision cut-off parabolic louver in a paracontoured fixture housing. This system complies with RP-1 and meets today’s lighting and energy manage-ment standards. The series is compatible with all of today’s popular ceiling systems. The Paralux V, PC|2 series is the solution for computer environ-ments and open office areas.
O R D E R I N G I N F O R M AT I O N
NOMINAL SIZE |
A |
B |
1' x 2' |
11-3/4" (298mm) |
7" (178mm) |
1' x 4' |
11-3/4" (298mm) |
7" (178mm) |
2' x 2' |
23-3/4" (603mm) |
6-1/8" (156mm) |
2' x 2' (8 cell) |
23-3/4" (603mm) |
6-3/4" (171mm) |
2' x 4' |
23-3/4" (603mm) |
6-1/8" (156mm) |
2' x 4' (18 cell) |
23-3/4" (603mm) |
6-5/8" (168mm) |
20" x 24" |
19-3/4" (502mm) |
6-1/8" (156mm) |
20" x 48" |
19-3/4" (502mm) |
7-3/8" (502mm) |
S A M P L E N U M B E R : 2 P 5 G A X - 3 3 2 S 3 9 M I - 1 2 0 V - E B 8 1 - U
HM= Hard
Metric
HR=Heat
Removal (1)
HRDO=Heat
Removal
Damper Open
HRDC=Heat
Removal
Damper Closed
Width 2'=2' width
Blank=1' width or 20" width
P=Paralux Louver
5=5" Louver Depth
Trim Type
G=Grid/Lay-in – Standard G or T=Concealed T
G or T=Slot Grid(2) F=Flange Trim MZ=Modular Trim
Convertible Fixture Standard G (Grid) Type-Fixtures can be field converted to T-option or vice-versa.(3) Fixture also adaptable with flanged or modular trims.
AX=Air Supply Floating Louver
Number
of Lamps
1, 2 or 3 lamps
(Not included)
Wattage (Length)
17=17W T8 (24") U15/8=31W T8 (24") BX40=40W Biaxial (24") 32=32W T8 (48")
Louver Color
S=Silver
Cell Configuration*
(See below for Louver Options)
Louver Finish
MI=Specular/Mirrored (Low Iridescent) VDT=VDT Soft Semi-Specular/Haze (Low Iridescent)
WB=White & Black Longitudinal Louver Blades (Specular/Mirrored Cross Blades) 1x4 only
WBVDT=White & Black Longitudinal Louver Blades (VDT Soft SemiSpecular/Haze Cross Blades) 1x4 only
X=Blank Side/Floating Louver - Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver with Directional Air Vane (Add V)
P R O D U C T I N F O R M AT I O N F O R PA R A L U X V
Housing |
Lamp |
Louver Cell |
Number |
Size |
Quantity |
Configuration* |
of Cells |
1' x 2' |
1 or 2 |
14 |
4 |
|
|
|
|
1' x 4' |
1 or 2 |
19 |
9 |
|
|
|
|
2' x 2' |
2 |
24 |
8 |
|
3 |
34 |
12 |
20" x 24" |
2 |
24 |
8 |
|
|
|
|
20" x 48" |
2 |
29 |
18 |
|
|
|
|
WW
Wall Wash
Voltage (4)
UNV=Universal
Voltage 120-277 (5)
347V=347 Volt
Options
GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal
Lamps - for lamps installed, see lamp options table
Flex - for flex installed, see flex ordering table
Emergency - for EM installed, see EM options table
Ballast Type (4)
Options
(See Options
Section)
Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton
Blank=Standard Magnetic Ballast (Biax & 20W) EB5 = T5 Biax Electronic Instant Start. Total
Harmonic Distortion < 20%
No. of Ballast 1, 2 or 3
LE3=T12 Magnetic Energy Saving EB2 =T12 Electronic Rapid Start.
No. of Ballast 1 or 2
ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%
No. of Ballast 1, 2 or 3
EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10%
No. of Ballast 1, 2 or 3
EB8 /PLUS= T8 Electronic Instant Start. High
|
|
|
|
|
|
Ballast Factor >1.13. Total Harmonic |
|
No. of |
Distortion < 20% |
||||
|
Ballast |
|||||
|
|
|||||
|
1, 2 or 3 |
|
||||
TEB5 =T5 Biax Electronic Instant Start. Total |
||||||
|
|
|
|
|
Harmonic Distortion < 10% |
|
|
No. |
of Ballast |
||||
|
1, 2 or 3 |
|
||||
DLS=Digital Lighting System Dimming |
(For complete details on generic or to specify manufacturer’s ballast see pg. 469)
2' x 4' |
2 |
29 |
18 |
|
3 |
39 |
27 |
*Example: 39= 3 rows of 9 (27 cells)
NOTES: (1) Integral end plate grid lock feature not available in heat removal. (2)An EQ Grid Clip is recommended for all 9/16" ceiling systems. (3)Convertibility applies to housing only, appropriate shielding media assemblies must be utilized. (4)Products also available in non-US voltages and frequencies for international markets.
(5) Not available when specifying emergencies, voltage must be specific.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.