CONTENTS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
COOPER LIGHTING - SURE-LITES® |
|||||||||||||||||||||||||||||
|
|
are an affordable, yet attractive, |
|
|
|
12” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
D E S C R I P T I O N |
|
|
|
D I M E N S I O N S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
The Contractor’s Choice FasTest™ Ultra |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
High-Capacity Emergency Lighting Units |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
OF |
|
|
alternative to standard two-headed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
[305mm] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
emergency lighting units. All |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
TABLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
21 11/16” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
components snap together to facilitate |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
installation in 5 minutes or less. Field |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
versatility is not sacrificed for cost, both |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
lighting heads offer horizontal and |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[551mm] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
vertical adjustability. Moreover, proper |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
operation of the transfer circuit and |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
19” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CC9 |
|||||||||
|
|
|
|
emergency lamps can be quickly and |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[483mm] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
safely verified by using a convenient |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CC10 |
||||||||
|
|
|
|
laser pointer (sold as an accessory). In |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8 7/16” |
|
|
|
|
|
|
||||||||||||
|
|
|
|
addition, Watchguard EMS self |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CC11 |
||||||||||
|
|
|
|
|
|
|
9 7/8” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[214mm] |
|
|
|
|
|
|
||||||||||||||||
|
|
|
|
diagnostic system is standard. |
|
|
|
[250mm] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CC12 |
||||||||||||
|
|
|
|
The CC Series Ultra High-Capacity |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
Emergency Lighting Units are ideal for |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
applications that demand the minimum |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
cost but also require maximum |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C o n t r a c t o r ’s C h o i c e |
||||||||
|
|
|
|
flexibility, reliability and convenience in |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S e l f - D i a g n o s t i c s |
|
|
|
|
|
|
|
U l t r a H i g h C a p a c i t y |
||||||||||||||||||
|
|
|
|
an attractive unit. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The self-diagnostic unit will |
|
|
E M E R G E N C Y L I G H T |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
automatically perform all tests |
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
required by UL924, and NFPA |
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
101. The system indicates the |
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
status of the exit at all times |
|
• Dual-Voltage Input 120/277 |
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
using the LED indicator near the |
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VAC, 60 Hz |
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
test switch on the side of the |
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
Verify proper operation of the |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
unit. A 90 minute battery power |
|
• |
Injection-Molded, Color- |
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(emergency mode) simulation |
|
|
Stable, High-Impact |
||||||||||||||||||||||
|
|
|
|
|
transfer circuit and emergency |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
test will occur randomly once |
|
|
UL 94-5V Rated |
|||||||||||||||||||||
|
|
|
|
|
lamps with convenient laser |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
every six months. |
|
|
|
|
|
|
|
Polycarbonate Housing and |
|||||||||||||||||
|
|
|
|
|
pointer (sold as an accessory). |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Mounting Plate |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• |
Designer white textured |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
finish |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• |
Maintenance Free Sealed |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
E L E C T R I C A L R AT I N G S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lead Calcium Battery |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||
|
|
|
|
|
|
|
Rated Wattage to 87 1/2% of Rated D.C. Voltage |
|
|
|
Lamp Information |
|
|
|
|
|
|
|
|
|
|
|
• |
Housing Has (8) Locations |
|||||||||||||||||||||
|
|
Model |
|
|
DC Voltage |
1 1/2 Hours |
Remote Capability |
|
|
|
Type |
|
Wattage |
Number |
Spacing(3) |
|
|
for Mounting of Heads; |
|||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Consult Factory (3 optional |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
CC9SD |
12 |
160 |
|
136W |
|
|
|
Incandescent |
|
12 ea. |
029-132 |
24' |
|
|
|
|
|
bottom-mount and 3 |
|||||||||||||||||||||||||
|
|
CC10SD |
12 |
200 |
|
176W |
|
|
|
Incandescent |
|
12 ea. |
029-132 |
24' |
|
|
|
|
|
optional topmount |
|||||||||||||||||||||||||
|
|
CC11SD |
12 |
240 |
|
216W |
|
|
|
Incandescent |
|
12 ea. |
029-132 |
24' |
|
|
|
|
|
locations) |
|||||||||||||||||||||||||
|
|
CC12SD |
12 |
300 |
|
276W |
|
|
|
Incandescent |
|
12 ea. |
029-132 |
24' |
|
|
|
|
• |
Knockouts/Cutouts |
|||||||||||||||||||||||||
|
|
CC9SDMRT |
12 |
160 |
|
136W |
|
|
|
MR16 |
|
12 ea. |
029-141 |
50’ |
|
||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
Provided in Housing for |
||||||||||||||||||||||||||||||||||||
|
|
CC10SDMRT |
12 |
200 |
|
176W |
|
|
|
MR16 |
|
12 ea. |
029-141 |
50’ |
|
|
|||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
Surface Conduit |
||||||||||||||||||||||||||||||||||||
|
|
CC11SDMRT |
12 |
240 |
|
216W |
|
|
|
MR16 |
|
12 ea. |
029-141 |
50’ |
|
|
|||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
Attachment |
||||||||||||||||||||||||||||||||||||
|
|
CC12SDMRT |
12 |
300 |
|
276W |
|
|
|
MR16 |
|
12 ea. |
029-141 |
50’ |
|
|
|||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• |
Watchguard EMS self |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
diagnostic system |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• |
Remote Photocell Test |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Switch with Automatic |
||
|
O R D E R I N G I N F O R M AT I O N |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
30-Sec. Test Upon Switch |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Activation |
|||||
|
S A M P L E N U M B E R : C C 9 S D M R T 2 1 4 2 S M |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Line-Latching, Solid-State |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
O p t i o n s (add as suffix) |
|
|
|
|
|
|
|
A c c e s s o r i e s (order separately) |
|
|
Voltage Limited Charger, |
||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Solid-State Switching, Low- |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage Disconnect, |
||
|
|
|
Model |
|
SQ=Square Head (12W Standard) |
|
BM=Bottom Mount Heads |
|
|
|
|
|
|
LASER=Key Chain, Red Laser Pointer |
|
|
Brownout Circuit, |
||||||||||||||||||||||||||||
|
|
|
Number |
|
MRT=MR16 Heads (12W Standard) |
|
(3 lamp max.) |
|
|
|
|
|
|
|
|
|
(activation tested at 30 feet) |
|
|
Overload/Short Circuit |
|||||||||||||||||||||||||
|
|
|
CC9SD |
|
Alternate Lamps - Specify quantity, |
Electrical Options |
|
|
|
|
|
|
VS1=Polycarbonate Vandal Shield |
|
|
Protection, Push-Button |
|||||||||||||||||||||||||||||
|
|
|
CC10SD |
|
lamp number (from Technical |
|
A=Ammeter |
|
|
|
|
|
|
VS1WP=Polycarbonate Vandal Shield |
|
|
Test Switch/Power Indicator |
||||||||||||||||||||||||||||
|
|
|
CC11SD |
|
Information section) and mounting |
V=Voltmeter |
|
|
|
|
|
|
|
|
|
Weather Resistant |
|
|
|
|
|
|
|
Light |
|||||||||||||||||||||
|
|
|
CC12SD |
|
location (below), e.g. |
|
TDM- Time Daily Monitor |
|
|
|
|
|
|
WG3=Wire Guard |
|
|
|
|
|
|
|
|
|
|
|
• |
UL 924, Life Safety NFPA |
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||
|
|
|
|
|
|
|
CC9SD2134SM319TM219BM |
|
CSK120=120V Cord Set |
|
|
|
|
|
|
2MSWH=Mounting Shelf |
|
|
|
|
|
|
|||||||||||||||||||||||
|
|
|
|
|
|
|
SM=Side Mount Heads |
|
CSK277= 277V Cord Set |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
101, NEC/OSHA, Most |
||||||||||||
|
|
|
|
|
|
|
|
|
(2 lamp max.) |
|
Other Options: Consult Cooper |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
State and Local Codes |
||||||||||||||||||
|
|
|
|
|
|
|
TM=Top Mount Heads (3 lamp max.) |
|
|
|
Lighting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Representative |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1)The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees. Cooper Lighting assumes no responsibility for local
requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. |
COOPER LIGHTING |
Commercial LIGHTS EMERGENCY
619