Problem: Failure to display ambient temperature
Solution:
1) Remove all batteries, reinsert into display first, and then sender.
2) Place remote sender closer to display.
3) Be sure all batteries are fresh.
4) Place Remote Control Sender and Temperature Station in position
so the straight-line signal is not passing through more than two or
three walls.
Problem: Temperatures do not match if units are placed next to each
other.
Solution:
Each temperature sensor is manufactured to be accurate to plus or
minus 1 degree under normal conditions, so the difference between
two sensors could be could be as much as 2 degrees. However,
the difference can be exaggerated further because the sensors are
designed for different working environments. The indoor sensor is
less responsive to ambient air currents because of the shielding effect
of the display’s case. In addition, the case can act as a heat sink to
absorb and store heat from external sources (i.e. handling of the case
or radiant heat). In addition, the much greater range of the ambient
temperature sensor requires a different calibration curve than the
indoor range. Error is usually greater at the extreme ends of a range,
making it harder to compare different ranges with different curves.
Under non-laboratory conditions, it is difficult to compensate for the
above factors and obtain an accurate comparison.
MAINTENANCE AND CARE
INSTRUCTIONS
• Extremetemperatures,vibration,andshockshouldbeavoidedto
prevent damage to the units.
• Cleandisplaysandunitswithasoft,dampcloth.Donotuse
solvents or scouring agents; they may mark the displays
and casings.
• Donotsubmergeinwater.
• Donotsubjecttheunitstounnecessaryheatorcoldbyplacing
them in the oven or freezer.
Important:
Opening the casings invalidates the warranty. Do not try to repair
the unit.
SPECIFICATIONS
Transmitting Frequency 433 MHz
Measuring Temperatures
Temperature Station
Ambient
32°F to 140°F with 0.2°F resolution
(0°C to 60.0°C with 0.1° resolution)
Temperature Station:
Fridge
-21.8°F to 157.2°F with 0.2°F resolution
(-29.9°C to 69.9°C with 0.1° resolution)
Transmitting accuracy +/- 2°F (+/-1°C)
Transmitting range Maximum 25m(80 feet) open space.
Temperature check
Ambient Every 60 seconds
Fridge Three times in 10 minutes
Batteries - (Alkaline recommended)
Remote Sender 2 x AAA, 1.5V
Temperature station 3 x AAA, 1.5V
Dimensions: (LxWxH)
Temperature station 2.75 x 0.92 x 4.25 in. (excluding table stand)
(70 x 23.5 x 108mm)
Remote control sender 2.56 x 0.90 x 2.79 in. (65 x 23 x 71mm)
Battery life Ranging from 1-10 months, varies subject to
operating temperature