
MODEL
X144D-AF-X
Cla-Val e-FlowMeter
for Ground Fueling Applications
The e-FlowMeter™ can be retrofitted to an existing
•
Cla-Val Automatic Control Valve or factory assembled
on a new valve
• Alleviates the need for an in-line meter and the
associated installation costs
• Provides flow data with accuracy +/- 2% of Full Scale
• Mounts on either inlet body tapping of the Cla-Val
Control Valve
• Stainless Steel Construction
• 4-20mA Loop Powered
flow direction
Installation view of the X144D-AF-X e-FlowMeter™
Display Features
• Flow Rate Display
• Totalizer Display
• Resettable
• Password Protected
• No opening to access buttons
Frequency Measurement
The X144D-AF-X e-FlowMeter™ uses the vortex
shedding method to measure flow. The meter is
inserted into the inlet tapping of the valve and the
measurement cylinder is oriented parallel to the
direction of flow. The flow enters the
measurement cylinder where it encounters the
bluff body, generating vortices, which in turn,
deflects off the piezoelectric sensor.
Patent Pending
The Cla-Val Model X144D-AF-X e-FlowMeter™
shedding insertion flow meter designed to be retrofitted into
a Cla-Val Automatic Control Valve to provide accurate flow
measurement data without the need to install a separate
meter.
The X144D-AF-X e-FlowMeter™ employs an innovative
swivel mechanism which allows the meter to be inserted
into tappings as small as 1/2-inch.
visit www.cla-val.com to learn more
about Cla-Val Aviation and
Ground Fueling Products
800.942.6326
Meter
Insert
Bluff
Body
is a vortex
The sensor counts the vortices and
communicates the data to the meterʼs integral
circuit board. The flow data is the converted to a
4-20mA signal.
Measurement
Cylinder
Vortices
Piezoelectric
Sensor

Installation Guidelines and Typical Applications
Information Transmission
4-20mA
Signal
Fuel
Control
Panel
Installation Locations
For optimum performance, it is recommended that the
valve in which the X144D-AF e-FlowMeter™ is
installed be located as shown below.
In Inlet Tapping
(vertical rise)
Downstream
of an Elbow
Outside Elbow
Information Transmission
The X144D-AF e-FlowMeter™ measures and
transmits flow information via a 4-20mA signal to
Fuel Control Panel.
> 5 Pipe Diameters
Either Inlet Tapping
Isolation Valve MUST be Wide Open or
5 pipe diameters upstream
(top view)
(top view)
Cla-Val Fueling Products
Cla-Val manufacturers a complete range of
aviation and ground fueling products including
top quality automatic control valves; hydrant pit
valves; couplers; and refueling nozzles for
commercial and military aviation applications.
340GF Series Underwing
Fueling Nozzles
90GF Series Pressure
Reducing Valve
Pipe Reducer Upstream
Note: Consult factory for other installation configurations
352GF Series Hydrant
Pit Valve

X144D-AF Dimensions
Accuracy within 2% of full scale
Flow Rate (GPM)
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
100 200 300 400 500 600 700 800
e-Flow/M
mag meter
Time (sec.)
e-Flow Meter
Mag Meter
X144 e-FlowMeter vs. Mag Meter
X144D-AF Sizes
Full Port Valve
Sizes
Reduced Port Valve
Sizes
Overall Length
(inches)
Insertion Length
(inches)
Pipe Thread
(NPT)
A 6.15 6.75 10.48 - -
B 2.3 2.8 6.8 - -
C
1 2 3 4
2, 2-1/2, 3 4, 6 8, 10
4 6, 8 10, 12* - -
1/2" 3/4" 1"
* For 12-inch and larger, please consult factory
X144D-AF e-FlowMeter™ Operational Flow Range
Line Size
inches (mm)
*2"
(50mm)
(100-49 Body)
2-1/2"
(65mm)3"(80mm)4"(100mm)6"(150mm)8"(200mm)
12*
- -
C
10"
(250mm)
B
A
12"
(300mm)
Typical Performance
Minimum Flow
(GPM)
Maximum Flow
(GPM)
Minimum Flow
(l/S)
Maximum Flow
(l/S)
10 10 15 25 60 100 160 230
210 300 460 800 1800 3150 4950 7000
0.65 0.65 1.0 1.5 3.8 6.3 10.0 15
13.3 18.9 29 50 110 200 310 440

Insertion Tool and Locking Ring
• Required for removal and reinsertion
• Tool allows the proper installation and alignment
of the bluff body to be parallel to upstream flow.
Cabling
• The unit is supplied with 30 feet of cable.
Approvals
Electrical Data & Product Labeling
Rating: II 3 G
Mfd. by Cla-Val Co.
Ex [d] ia IIA T5
1701 Placentia Avenue
Costa Mesa, CA 92627 USA
www.cla-val.com • 800.942.6326
Self-certification by Cla-Val Co.
1701 Placentia Avenue
Costa Mesa, CA 92627,
per Annex VIII, Internal Control
Production per Annex VIII
Model #: X144D-AF-X
Serial #:
EX [d] ia IIA T5
X144D-AF-X e-FlowMeter Analog Range (4-20mA Scaling): Factory Settings
2"
X144D-AF-X Insertion Tool
Port Style
Line Size
inches (mm)
(50)
(100-49
Body)
2-1/2"
(65)
3"
(80)
4"
(100)6"(150)8"(200)
Max. Voltage : 30 VDC
Max. Power : 750mW
Signal Output : 4-20mA
Max. Temp.
: 100° C
10"
(250)
12"
(300)
Full Port Valves
4mA = 0
(GPM - l/s)
Full Port
Pulse Weight
= 250ms
Reduced Port
Valves
4mA = 0
(GPM- l/s)
Reduced Port
Valves
Pulse Weight =
250ms
Note: pulse length = 250ms
20mA Range (GPM) 260 375 575 1000 2250 3900 6000 8750
20mA Range (GPM)
20mA Range (l/s) 16.4 23.7 36.3 63.1 140 245 380 550
Gal/Pulse 5 6.5 9.5 17 38 65 100 150
l/Pulse 19 25 36 65 145 245 380 565
675 1600 2900 4500 5650
20mA Range (l/s) 42.5 100 180 285 355
not available
Gal/Pulse 11.5 26 48 75 95
l/Pulse 44 99 180 285 360
Represented By:
LA-VAL
PO Box 1325 Newport Beach CA 92659-0325
Phone: 949-722-4800 Fax: 949-548-5441
www.cla-val.com
E-X144D-AF-X ( 09/2012)
©COPYRIGHT CLA-VAL 2012 Printed in USA • Specifications subject to change without notice.