Clarke Boxer 2 18/150, 2245316 User guide

150L BELT DRIVEN AIR COMPRESSOR
MODEL NO: BOXER II 18/150
PART NO: 2245316
OPERATION & MAINTENANCE
INSTRUCTIONS
ORIGINAL INSTRUCTIONS GC0122 rev 1
Thank you for purchasing this CLARKE 200L Air Compressor.
Before attempting to operate the machine, it is essential that you read this manual thoroughly and follow all instructions given. This will ensure the safety of yourself and others and you can look forward to the product giving you long and satisfactory service.

GUARANTEE

This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights.

ENVIRONMENTAL RECYCLING POLICY

Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.
2
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

SAFETY PRECAUTIONS

Before using your compressor it is in your own interest to read and pay attention to the following safety precautions.
1. Compressed air is dangerous. DO NOT point a jet of air at persons or animals, and do not discharge compressed air against the skin.
2. DO NOT operate your compressor with the guard removed.
3. Repairs must only be carried out by a qualified engineer. If problems occur, contact your CLARKE dealer.
4. Before carrying out any maintenance make sure that the pressure is released from the air reservoir and that the compressor is disconnected from the electrical supply.
5. DO NOT leave pressure in the receiver overnight or when transporting.
6. DO NOT adjust or tamper with the safety valves. The maximum pressure is factory set, and clearly marked on the compressor.
7. DO NOT operate in wet or damp conditions. Keep the compressor dry at all times. Similarly, clean air will allow the compressor to work efficiently. DO NOT use in dusty or otherwise dirty locations.
8. Some of the metal parts can become quite hot during operation. DO NOT touch/ remove these until the compressor has cooled down.
9. ALWAYS set any pressure regulator to the recommended setting for the tool.
10. When spraying flammable materials e.g. cellulose paint, ensure that there is sufficient airflow and keep clear of any source of ignition.
11. Before spraying any material always consult paint manufacturers instructions for safety and usage.
12. Protect yourself. Goggles will protect your eyes from flying particles. Face masks will protect you against paint spray and fumes.
13. DO NOT apply strain to electrical cables and make sure that air hoses are not kinked or wrapped around the compressor.
14. When disconnecting air hoses or other equipment from your compressor, make sure that the air supply is turned off at the outlet and vent all pressurised air from within the reservoir and other equipment attached to it.
15. Make sure that children and animals are kept well away from the compressor and any equipment attached to it.
16. Make sure that all individuals using the compressor have had any necessary training and have read and fully understand these operating instructions.
17. Make sure that any equipment or tool used in conjunction with your compressor, has a safe working pressure exceeding that of the compressor.
18. Be careful when transporting the compressor to prevent tipping over.
19. Permanently installed systems must be installed by a competent engineer.
20. These compressors produce noise levels in excess of 70dB(A). Persons working near the compressor must be supplied with ear protection.
3
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

SAFETY SYMBOLS

Read this instruction booklet carefully before positioning, operating or adjusting the compressor.
Risk of electric shock. The compressor must be disconnected from the mains supply before removing any covers. DO NOT use in a damp environment.
Risk of accidental start-up. The compressor could start automatically in the event of a power cut and subsequent reset. DO NOT move the compressor while it is connected to the power source, or when the tank is filled with compressed air.
This compressor contains surfaces which may reach a high temperature during operation. NEVER operate with the motor housing removed.
Wear safety goggles when using this compressor
Wear ear protectors when using this compressor
This compressor produces a high sound level during operation.
4
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

INSTALLATION

Before installing your machine, check that its air output is sufficient for the equipment to be used. The air output from the compressor must be more than the volume of air required. We recommend the following:
1. 1. Firm and level site, and the use of floor mountings for stationary compressors - anti-vibration pads. (Do not bolt machines directly to the floor).
2. Dust and damp free environment.
3. Adequate ventilation for:-
• Air intake to compressor pump (in order to draw in clean air).
• Cooling to compressor pump, and electric motor.
4. To allow sufficient access for servicing, a minimum clearance of 500mm must be allowed around the machine.
5. The power cable from the main supply must be large enough to carry the starting and running load of the electric motor. This is particularly relevant if the compressor is some distance from the source of supply.
6. Electrical installations should be completed by a qualified electrician.

ELECTRICAL CONNECTIONS

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY.
Connect the three core mains cable to a suitable industrial supply isolator, or heavy duty plug meeting the requirements of BS EN 60309. This compressor must be connected to a supply having a rated capacity of greater than 16 Amps.
A normal 13 Amp (BS1363) plug must NOT be used.
WARNING: THIS APPLIANCE MUST BE EARTHED.
IMPORTANT: The wires in this mains lead are coloured in accordance with the following code:
GREEN AND YELLOW - EARTH (E)
BLUE - NEUTRAL (N)
BROWN - LIVE (L)
5
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying terminals, proceed as follows:
• Connect GREEN AND YELLOW coloured cable to terminal marked “E” or Earth Symbol or coloured Green and Yellow.
• Connect BROWN cable to terminal marked ‘L’ or coloured Red.
Connect BLUE cable to terminal marked “N’ or coloured Black.

BEFORE USE

CAUTION: TO PREVENT INJURY, GET ASSISTANCE WHEN LIFTING OR MOVING THIS COMPRESSOR.
Before connecting your compressor to the power supply, check the following:
• Set the ON/OFF switch to the OFF position (pushed down).
• Make sure that the compressor is on level ground.
• Make sure that the supply voltage matches the voltage shown on the data label.

CHECK THE OIL LEVEL

1. .Ensure the oil level is filled up to the mark on the sightglass.
2. If low, top up after unscrewing the filler plug.
• Only use CLARKE ISO100
(SAE30) compressor oil, available from your CLARKE dealer Part No. 3050796.
• Take care not to overfill.
6
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

OPERATION

If the compressor has not been used for more then 24 hours, open the drain valve (on the bottom of the reservoir) and drain any condensate which has collected. See page 10.

MOVING THE AIR COMPRESSOR

• Stop the compressor and disconnect it from the power supply before you move it.
DO NOT lift by (or put strain on) valves or hoses.
• Avoid moving the machine if the tank is fully pressurised.

ATTACHING AIR TOOLS

WARNING: BEFORE CONNECTING AIR TOOLS, MAKE SURE THAT YOU READ THE INSTRUCTIONS SUPPLIED WITH THE TOOL, ALSO ENSURE THAT THE TOOL IS SUITABLE FOR USE WITH THE COMPRESSOR AND HOSE SPECIFICATIONS.
1. Attach the air hose to the outlet valves.
2. Attach the air tool to the other end of the air hose.
3. Turn the outlet valve handle to the on position.
NOTE: The outlet valve is shown
without the air hose fitted for clarity.
NOTE: To adjust the output pressure
we recommend that a pressure regulator (not supplied) be fitted between the compressor and the tool.
7
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

TURNING THE COMPRESSOR ON

1. Plug the compressor into the power supply.
2. Lift the On/Off button.
• The compressor will operate until the reservoir is fully pressurised. It will then shut down.
• The compressor will start up again when the pressure in the reservoir decreases.

CHECKING THE SAFETY VALVE

To make sure that the safety valve works correctly;
1. Unscrew and pull the knurled part of the safety valve.
• Air will be released when you
pull hard on the valve end and stop when released.
2. If the valve does not operate in this way, do not use the compressor. The compressor must be repaired by a qualified service agent.
3. Once tested, screw the knurled part back.
WARNING: DO NOT REMOVE OR TRY TO ADJUST THE SAFETY VALVE.
8
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

REMOVING TOOLS FROM THE AIR HOSE

1. Push down on the On/Off button to stop the compressor.
2. Turn the outlet valve handle to the off position.
3. Operate the tool to depressurise the air hose.
4. Disconnect the tool from the hose.

TURNING THE COMPRESSOR OFF

1. Follow steps 1-3 in “Removing Tools from the Air Hose” above.
2. Disconnect the compressor from the power supply.
3. Slowly open the outlet valve to depressurise the reservoir.
• You will hear a hissing sound as the reservoir depressurises.
4. Do not leave the compressor unattended if the reservoir is pressurised.
9
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

DRAINING THE RESERVOIR

CAUTION: YOU MUST DRAIN THE RESERVOIR AFTER EACH DAYS USE AND BEFORE YOU PUT YOUR COMPRESSOR INTO STORAGE.
1. Turn the compressor off and disconnect from the power
supply.
2. Put a container below the drain valve to collect the condensate.
3. Open the drain valve slowly.
• Condensation will drain from
the reservoir.
4. Close the drain valve when the reservoir has fully drained.

USING THE RESET BUTTON

This compressor has a thermal overload device.
If the motor gets too hot, the thermal overload device cuts the power which prevents damage to the motor.
If the thermal overload device operates, let the motor cool down for 5 minutes and push the reset button.
If you start the compressor and the overload cutout operates again, stop the compressor and disconnect from the power supply and have your compressor examined by a qualified service agent.
10
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

MAINTENANCE

WARNING: MAKE SURE THAT THE COMPRESSOR IS DISCONNECTED FROM THE ELECTRICAL SUPPLY BEFORE CARRYING OUT ANY MAINTENANCE

DRAIN THE RESERVOIR

After use, always open the drain valve to make sure that any condensate is drained off.

CHECKING THE OIL

Ensure the oil level is between the min and max marks on the dipstick. See “Check the Oil level” on page 6 and top-up if necessary - (use CLARKE ISO100 (SAE30) compressor oil, available from your local CLARKE dealer).

CLEANING THE AIR FILTER

The air filter must be examined monthly or more often in dusty conditions.
1. Remove the securing bolt with a 7/32” hex key and pull the filter from the engine.
2. Remove the filter element and clean the filter using a soft brush.
• If necessary, the filter can be
carefully cleaned in warm soapy water.
• Rinse and let the filter dry
completely before refitting.
• If the filter or filter element is damaged you must replace it.
3. Reassemble the filter and refit it to the compressor.
11
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

REPLACING THE OIL

After the first 100 hours use, replace the oil using CLARKE (SAE30) compressor oil. Then replace the oil after every 500 hours of operation or every 6 months.
To empty the oil from the machine, remove the oil drain plug from the crankcase.

CHECKING THE NON-RETURN VALVE

If the reservoir pressure decreases for no apparent reason, it is possible that the non-return valve is leaking. To check this;
1. Make sure that the reservoir is not under pressure and the compressor is switched OFF.
2. Examine the non-return valve, and replace the gasket and valve if necessary.
12
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

REPLACING THE DRIVE BELT

WARNING: MAKE SURE THAT THE COMPRESSOR IS DISCONNECTED FROM THE ELECTRICAL SUPPLY BEFORE REPLACING THE DRIVE BELT.
1. Rotate the clips on the front of the safety cage.
2. Remove the front of the cage and take out the worn or broken drive belt.
3. Place the new drive belt over the small pulley.
4. Position part of the drive belt over the large pulley as shown.
5. Rotate the large pulley by hand in a clockwise direction whilst guiding the belt on to it.
• Take care to avoid trapping
your fingers between the pulley and belt.
6. Replace the cage and secure before use.
WARNING: NEVER USE THE COMPRESSOR WITH THE GUARD REMOVED.
13
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

TROUBLESHOOTING

CAUTION: DO NOT TRY TO REPAIR OR ADJUSTMENT IF YOU ARE UNCERTAIN. IF YOU HAVE ANY QUERIES, CONTACT YOUR CLARKE DEALER.
PROBLEM PROBABLE CAUSE REMEDY
The compressor has stopped and does not start.
The compressor does not reach the set pressure and overheats easily.
Compressor does not start.
Air leaking from the non-return valve when the compressor is not running.
Compressor is very noisy and makes metallic knocking sound.
Bad electrical connections.
Overload cutout switch has tripped.
Motor windings burnt out. 1. Contact your CLARKE
Compressor head gasket blown or valve broken.
The reservoir has already fully pressurised.
Faulty non-return valve. 1. Drain receiver completely
Compressor is damaged and needs overhaul.
1. Check electrical connections.
2. Clean and tighten if necessary.
1. Switch off and wait approx 5 minutes.
2. Press the reset button and switch on again.
dealer for a replacement motor.
1. Return the machine to your nearest CLARKE dealer.
1. Open drain valve to expel air. Compressor should start again when pressure reduces.
of air.
2. Remove the valve end plug.
3. Carefully clean the valve seat and the gasket
4. Reassemble.
1. Return the machine to your nearest CLARKE dealer.
14
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

COMPONENT PARTS

15
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

COMPONENT PARTS LIST

NO DESCRIPTION
1 Crankcase 31 Pressure Switch
2 Cylinder block 32 Power Cable
3 Cylinder Head 33 Motor
4 Crankshaft 34 Belt Guard
5 Lower Cover 35 Safety valve
6 Kit Valve Holder 36 Pump assembly
7 Conrod 37 Feet set
8 Air Filter Assembly (complete) 38 Drive pulley
9 Air cooler 39 Drive Belt
10 End Cover 40 Outlet Tap
11 Bearing Retainer 41 Drain Valve
12 Flywheel 42 Upright Connector
13 Bearing 43 Connector
14 Oil Filler 44 Pressure Gauge
15 Oil seal 45 Oil Seal
16 O-ring 46 Drain plug
17 Bolt 47 Sightglass
18 Washer
19 Piston Ring Set
20 Piston
21 Gudgeon pin
22 Circlip
23 Piston Kit
24 Intake Air Filter
25 Gasket Set
26 Cold Start Valve
27 Non Return Valve
28 Rilsan Tube
29 Plastic Shroud
30 Delivery pipe
16
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

SPECIFICATIONS

MODEL BOXER 18/150
Part Number 2245316
Motor size 4HP
Voltage 230 VAC (50Hz)
Air Displacement 504.8L/min (18 cfm)
Max Pressure 10 Bar (145psi)
Receiver Capacity 150 L
Ingress Protection IP20
Duty cycle S3/50%
Oil requirements Compressor oil SAE30
Oil capacity 0.4L
Dimensions (L x W x H) 1260 x 450 x 810 mm
Guaranteed Sound Power Level 97 dB(A)
Weight 97 kg
Please note that the details and specifications contained herein, are correct at the time of going to print. We reserve the right to change specifications at any time without prior notice.
17
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

DECLARATION OF CONFORMITY

18
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

DECLARATION OF CONFORMITY

19
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Loading...