Cisco IE2100, 0L-1570-01 User Manual

0 (0)

C H A P T E R 2

Preparing for Installation

This chapter describes the safety instructions and site requirements needed for installing the IE2100 Series device and guides you through installation preparation. It contains information about:

Safety

Preparing Your Site for Installation

Rack-Mounting the System

Required Tools and Equipment

Safety

This section provides safety information for installing this product.

Warnings and Cautions

Note Read the installation instructions in “Installing and Configuring the IE2100 Series” before you connect the system to its power source because you must be extremely careful when installing electrical devices. Failure to read and follow these guidelines could lead to an unsuccessful installation and possible damage to the system and components.

You should observe the following safety guidelines when working with any equipment that connects to electrical power or telephone wiring. They can help you avoid injuring yourself and damaging the IE2100 Series.

The following warnings and cautions are provided to help you prevent damage to the devices or injury to yourself:

Warning The safety cover is an integral part of the product. Do not operate the unit without the safety cover installed. Operating the unit without the cover in place will invalidate the safety approvals and pose a risk of fire and electrical hazards.

Cisco Intelligence Engine 2100 Series Configuration Registrar Manual

 

OL-1570-01

2-1

 

 

 

Cisco IE2100, 0L-1570-01 User Manual

Chapter 2 Preparing for Installation

Safety

Warning Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available.

Warning Before working on a chassis or working near power supplies, unplug the power cord on AC units; disconnect the power at the circuit breaker on DC units.

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

Warning This product relies on the building’s installation for short-circuit (overcurrent) protection. Make sure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. and 240 VAC, 10A international are used on the phase conductors (all current-carrying conductors).

Warning This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use.

Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.

Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.

Warning Ultimate disposal of this product should be handled according to all national laws and regulations.

Warning Before working on a system that has an On/Off switch, turn OFF the power and unplug the power cord.

Warning Read the installation instructions before you connect the system to its power source.

Warning The device is designed to work with TN power systems.

Cisco Intelligence Engine 2100 Series Configuration Registrar Manual

2-2

OL-1570-01

 

 

Chapter 2 Preparing for Installation

Safety

Warning The ports labeled “10BaseT”, “100BaseTX”, and “10/100” are safety extra-low voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits. Avoid connecting these circuits to telephone network voltage (TNV) circuits.

Warning There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

Working with Electricity

Follow these guidelines when working on electrical equipment:

Locate the emergency power-off switch for the room in which you are working. If an electrical accident occurs, you can act quickly to turn off the system.

Disconnect all power by powering off the system and unplugging the power cord before:

Installing or removing a chassis

Working near power supplies

Do not work alone if potentially hazardous conditions exist.

Never assume that power is disconnected from a circuit; always check the circuit.

Look carefully for possible hazards in your work area, such as moist floors, underground power extension cables, frayed power cords, and missing safety grounds

If an electrical accident occurs:

Use caution: do not become a victim yourself.

Power off the system.

If possible, send another person to get medical aid. Otherwise, assess the victim’s condition, then call for help.

Determine if the person needs rescue breathing or external cardiac compressions; then take appropriate action.

Disconnect all power and external cables before installing or removing a chassis.

Never install equipment that appears damaged.

Never install telephone wiring during a lightning storm.

Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Always use caution when installing or modifying telephone lines.

Never perform any action that creates a potential hazard to people or makes the equipment unsafe.

Cisco Intelligence Engine 2100 Series Configuration Registrar Manual

 

OL-1570-01

2-3

 

 

 

Chapter 2 Preparing for Installation

Preparing Your Site for Installation

Preventing Damage from Electrostatic Discharge

Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs when electronic components are handled improperly and can result in complete or intermittent failures.

Always follow ESD-prevention procedures when removing and replacing components. Verify that the chassis is electrically connected to earth ground. Wear an ESD-preventive wrist strap, making sure that it makes good skin contact. Connect the grounding clip to an unpainted surface of the chassis frame to safely ground ESD voltages. To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.

Periodically check the resistance value of the antistatic strap, which should be between 1 and 10 Mohms.

Preventing EMI

When you run wires for any significant distance in an electromagnetic field, electromagnetic interference (EMI) can occur between the field and the signals on the wires.

Note that:

Bad plant wiring can result in radio frequency interference (RFI).

Strong EMI, especially when it is caused by lightning or radio transmitters, can destroy the signal drivers and receivers in the system, and can even create an electrical hazard by conducting power surges through lines and into the system.

To predict and remedy strong EMI, consult RFI experts.

Covering Empty Slots

Ensure that all cards, faceplates, and covers are in place. Blank faceplates and cover panels are used to:

Prevent exposure to voltages and currents inside the chassis.

Help contain electromagnetic interference (EMI) that might disrupt other equipment.

Direct the flow of cooling air through the chassis.

Preparing Your Site for Installation

Make sure your site is prepared properly before beginning installation.

Environmental

When planning your site layout and equipment locations, keep in mind the precautions described in this section to help avoid equipment failures and reduce the possibility of environmentally caused shutdowns. If you are currently experiencing shutdowns or unusually high errors with your existing equipment, these precautions will help you isolate the cause of failures and prevent future problems.

Use the following precautions when planning the operating environment for your IE2100 Series.

Cisco Intelligence Engine 2100 Series Configuration Registrar Manual

2-4

OL-1570-01

 

 

Loading...
+ 8 hidden pages