Cisco Systems IPMUX-1, IPMUX-1E User Manual

0 (0)
Installation and Operation Manual
IPmux-1, IPmux-1E
TDMoIP Gateways
IPmux-1, IPmux-1E
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications.
Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the IPmux-1, IPmux-1E and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD.
IPmux-1, IPmux-1E is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark.
You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the IPmux­1, IPmux-1E. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the IPmux-1, IPmux-1E, based on or derived in any way from the IPmux-1, IPmux-1E. Your undertaking in this paragraph shall survive the termination of this Agreement.
This Agreement is effective upon your opening of the IPmux-1, IPmux-1E package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the IPmux-1, IPmux-1E and all copies and portions thereof.
For further information contact RAD at the address below or contact your local distributor.
International Headquarters RAD Data Communications Ltd.
24 Raoul Wallenberg St. Tel Aviv 69719 Israel Tel: 972-3-6458181 Fax: 972-3-6498250 E-mail: rad@rad.com
© 1999-2003 RAD Data Communications Ltd. Publication No. 114-200-06/03
U.S. Headquarters RAD Data Communications Inc.
900 Corporate Drive Mahwah, NJ 07430 USA Tel: (201) 529-1100, Toll free: 1-800-444-7234 Fax: (201) 529-5777 E-mail: market@radusa.com
Limited Warranty
RAD warrants to DISTRIBUTOR that the hardware in the IPmux-1, IPmux-1E to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR.
If, during the warranty period, any component part of the equipment becomes defective by reason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have the option to choose the appropriate corrective action: a) supply a replacement part, or b) request return of equipment to its plant for repair, or c) perform necessary repair at the equipment's location. In the event that RAD requests the return of equipment, each party shall pay one-way shipping costs.
RAD shall be released from all obligations under its warranty in the event that the equipment has been subjected to misuse, neglect, accident or improper installation, or if repairs or modifications were made by persons other than RAD's own authorized service personnel, unless such repairs by others were made with the written consent of RAD.
The above warranty is in lieu of all other warranties, expressed or implied. There are no warranties which extend beyond the face hereof, including, but not limited to, warranties of merchantability and fitness for a particular purpose, and in no event shall RAD be liable for consequential damages.
RAD shall not be liable to any person for any special or indirect damages, including, but not limited to, lost profits from any cause whatsoever arising from or in any way connected with the manufacture, sale, handling, repair, maintenance or use of the IPmux-1, IPmux-1E, and in no event shall RAD's liability exceed the purchase price of the IPmux-1, IPmux-1E.
DISTRIBUTOR shall be responsible to its customers for any and all warranties which it makes relating to IPmux-1, IPmux-1E and for ensuring that replacements and other adjustments required in connection with the said warranties are satisfactory.
Software components in the IPmux-1, IPmux-1E are provided "as is" and without warranty of any kind. RAD disclaims all warranties including the implied warranties of merchantability and fitness for a particular purpose. RAD shall not be liable for any loss of use, interruption of business or indirect, special, incidental or consequential damages of any kind. In spite of the above RAD shall do its best to provide error-free software products and shall offer free Software updates during the warranty period under this Agreement.
RAD's cumulative liability to you or any other party for any loss or damages resulting from any claims, demands, or actions arising out of or relating to this Agreement and the IPmux-1, IPmux-1E shall not exceed the sum paid to RAD for the purchase of the IPmux-1, IPmux-1E. In no event shall RAD be liable for any indirect, incidental, consequential, special, or exemplary damages or lost profits, even if RAD has been advised of the possibility of such damages.
This Agreement shall be construed and governed in accordance with the laws of the State of Israel.
General Safety Instructions
The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual.
Safety Symbols
This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel.
Warning
Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines.
.
Warning
Protective earth: the marked lug or terminal should be connected to the building protective earth bus.
Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached. Please observe the following precautions:
Before turning on the equipment, make sure that the fiber optic cable is intact and is connected to the transmitter.
Do not attempt to adjust the laser drive current.
Do not use broken or unterminated fiber-optic cables/connectors or look
straight at the laser beam.
The use of optical devices with the equipment will increase eye hazard.
Use of controls, adjustments or performing procedures other than those
specified herein, may result in hazardous radiation exposure.
ATTENTION: The laser beam may be invisible!
Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user.
Handling Energized Products
General Safety Practices
Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist.
Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts.
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is provided on the product, it should be connected to the protective earth at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and cabinets.
Always make the ground connection first and disconnect it last. Do not connect telecommunication cables to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the ground.
Connection of AC Mains
Make sure that the electrical installation complies with local codes.
Always connect the AC plug to a wall socket with a protective ground.
The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A.
Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation.
Connection of DC Mains
Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded.
Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards.
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to qualified service and maintenance personnel.
Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes.
The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A.
Before connecting the DC supply wires, ensure that power is removed form the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position.
A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation.
Connection of Data and Telecommunications Cables
Data and telecommunication interfaces are classified according to their safety status.
The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manual.
Ports Safety Status
V.11, V.28, V.35, V.36, RS-530, X.21, 10 BaseT, 100 BaseT, Unbalanced E1, E2, E3, STM, DS-2, DS-3, S-Interface ISDN, Analog voice E&M
xDSL (without feeding voltage), Balanced E1, T1, Sub E1/T1
FXS (Foreign Exchange Subscriber) TNV-2 Telecommunication Network Voltage-2:
FXO (Foreign Exchange Office), xDSL (with feeding voltage), U-Interface ISDN
SELV Safety Extra Low Voltage:
Ports which do not present a safety hazard. Usually up to 30 VAC or 60 VDC.
TNV-1 Telecommunication Network Voltage-1:
Ports whose normal operating voltage is within the limits of SELV, on which overvoltages from telecommunications networks are possible.
Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are not possible. These ports are not permitted to be directly connected to external telephone and data lines.
TNV-3 Telecommunication Network Voltage-3:
Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are possible.
Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a qualified safety engineer.
Always make sure that the equipment is grounded before connecting telecommunication cables. Do not disconnect the ground connection before disconnecting all telecommunications cables.
Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables. Extra caution should be exercised during thunderstorms.
When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The earthing and bonding of the ground connections should comply with the local codes.
The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between exposed external wires and the AC power lines. In order to reduce the risk, there are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors.
Caution
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords.
Attention
Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure.
Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such cases, a notice will be given in the installation instructions.
Do not attempt to tamper with any carrier-provided equipment or connection hardware.
Electromagnetic Compatibility (EMC)
The equipment is designed and approved to comply with the electromagnetic regulations of major regulatory bodies. The following instructions may enhance the performance of the equipment and will provide better protection against excessive emission and better immunity against disturbances.
A good earth connection is essential. When installing the equipment in a rack, make sure to remove all traces of paint from the mounting points. Use suitable lock-washers and torque. If an external grounding lug is provided, connect it to the earth bus using braided wire as short as possible.
The equipment is designed to comply with EMC requirements when connecting it with unshielded twisted pair (UTP) cables. However, the use of shielded wires is always recommended, especially for high-rate data. In some cases, when unshielded wires are used, ferrite cores should be installed on certain cables. In such cases, special instructions are provided in the manual.
Disconnect all wires which are not in permanent use, such as cables used for one-time configuration.
The compliance of the equipment with the regulations for conducted emission on the data lines is dependent on the cable quality. The emission is tested for UTP with 80 dB longitudinal conversion loss (LCL).
Unless otherwise specified or described in the manual, TNV-1 and TNV-3 ports provide secondary protection against surges on the data lines. Primary protectors should be provided in the building installation.
The equipment is designed to provide adequate protection against electro-static discharge (ESD). However, it is good working practice to use caution when connecting cables terminated with plastic connectors (without a grounded metal hood, such as flat cables) to sensitive data lines. Before connecting such cables, discharge yourself by touching earth ground or wear an ESD preventive wrist strap.
FCC-15 User Information
This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the Installation and Operation manual, may cause harmful interference to the radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Canadian Emission Requirements
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Warning per EN 55022 (CISPR-22)
Warning
Avertissement
Achtung
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user will be required to take adequate measures.
Cet appareil est un appareil de Classe A. Dans un environnement résidentiel, cet appareil peut provoquer des brouillages radioélectriques. Dans ces cas, il peut être demandé à l’utilisateur de prendre les mesures appropriées.
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkströrungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.
Declaration of Conformity
Manufacturer's Name: RAD Data Communications Ltd.
Manufacturer's Address: 24 Raoul Wallenberg St.
Tel Aviv 69719
Israel
declares that the product:
Product Name: IPmux-1, IPmux-1E
conforms to the following standard(s) or other normative document(s):
EMC: EN 55022 (1994) Limits and methods of measurement of radio disturbance
characteristics of information technology equipment.
EN 50024 (1998) Information technology equipment –Immunity
characteristics – Limits and methods of measurement.
Safety: EN 60950/A4 (1996) Safety of information technology equipment, including
electrical business equipment.
Supplementary Information:
The products herewith comply with the requirements of the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC and the R & TTE directive 99/5/EC for wired equipment. The products were tested in a typical configuration.
Tel Aviv, March 18, 2001
Haim Karshen VP Quality
European Contact: RAD Data Communications GmbH, Otto-Hahn-Str. 28-30, 85521 Ottobrunn-Riemerling, Germany
Preface
Foreword
This manual describes the technical characteristics, applications, installation and operation of IPmux-1 and IPmux-1E. In this manual the products will be referred to as IPmux-1/1E.
Manual Organization
This manual is organized as follows:
Chapter 1. Introduction
presents the main features versions, applications, functional description, and lists the technical specifications of IPmux-1/1E.
Chapter 2. Installation
provides detailed installation and operation instructions for IPmux-1/1E.
Chapter 3. Operation
provides general instructions for getting started, managing IPmux-1/1E by means of terminals and Telnet hosts, and provides typical configuration procedures.
Chapter 4. Tests and Diagnostics
describes the diagnostic and performance monitoring functions supported by IPmux-1/1E.
Appendix A. Boot Sequence for Downloading Software
provides instructions for the installation of new software releases.
Appendix B. Telnet
details management by Telnet.
Appendix C. SNMP Management
describes the SNMP and IP environments, and provides background information regarding the handling of management traffic.
Appendix D. TFTP Download Procedures
details management by Telnet.
Appendix E. Parameters and Screens
describes the configuration screens and parameters.
Conventions
Note
Caution
Warning
A note draws attention to a general rule for a procedure, or to exceptions to a rule.
A caution warns of possible damage to the equipment if a procedure is not followed correctly.
A warning alerts to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the equipment. If these instructions are not followed exactly, possible bodily injury may occur.
IPmux-1, IPmux-1E
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications.
Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the IPmux-1, IPmux-1E and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD.
IPmux-1, IPmux-1E is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark.
You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the IPmux­1, IPmux-1E. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the IPmux-1, IPmux-1E, based on or derived in any way from the IPmux-1, IPmux-1E. Your undertaking in this paragraph shall survive the termination of this Agreement.
This Agreement is effective upon your opening of the IPmux-1, IPmux-1E package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the IPmux-1, IPmux-1E and all copies and portions thereof.
For further information contact RAD at the address below or contact your local distributor.
International Headquarters RAD Data Communications Ltd.
24 Raoul Wallenberg St. Tel Aviv 69719 Israel Tel: 972-3-6458181 Fax: 972-3-6498250 E-mail: rad@rad.com
© 1999-2003 RAD Data Communications Ltd. Publication No. 114-200-06/03
U.S. Headquarters RAD Data Communications Inc.
900 Corporate Drive Mahwah, NJ 07430 USA Tel: (201) 529-1100, Toll free: 1-800-444-7234 Fax: (201) 529-5777 E-mail: market@radusa.com
Limited Warranty
RAD warrants to DISTRIBUTOR that the hardware in the IPmux-1, IPmux-1E to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR.
If, during the warranty period, any component part of the equipment becomes defective by reason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have the option to choose the appropriate corrective action: a) supply a replacement part, or b) request return of equipment to its plant for repair, or c) perform necessary repair at the equipment's location. In the event that RAD requests the return of equipment, each party shall pay one-way shipping costs.
RAD shall be released from all obligations under its warranty in the event that the equipment has been subjected to misuse, neglect, accident or improper installation, or if repairs or modifications were made by persons other than RAD's own authorized service personnel, unless such repairs by others were made with the written consent of RAD.
The above warranty is in lieu of all other warranties, expressed or implied. There are no warranties which extend beyond the face hereof, including, but not limited to, warranties of merchantability and fitness for a particular purpose, and in no event shall RAD be liable for consequential damages.
RAD shall not be liable to any person for any special or indirect damages, including, but not limited to, lost profits from any cause whatsoever arising from or in any way connected with the manufacture, sale, handling, repair, maintenance or use of the IPmux-1, IPmux-1E, and in no event shall RAD's liability exceed the purchase price of the IPmux-1, IPmux-1E.
DISTRIBUTOR shall be responsible to its customers for any and all warranties which it makes relating to IPmux-1, IPmux-1E and for ensuring that replacements and other adjustments required in connection with the said warranties are satisfactory.
Software components in the IPmux-1, IPmux-1E are provided "as is" and without warranty of any kind. RAD disclaims all warranties including the implied warranties of merchantability and fitness for a particular purpose. RAD shall not be liable for any loss of use, interruption of business or indirect, special, incidental or consequential damages of any kind. In spite of the above RAD shall do its best to provide error-free software products and shall offer free Software updates during the warranty period under this Agreement.
RAD's cumulative liability to you or any other party for any loss or damages resulting from any claims, demands, or actions arising out of or relating to this Agreement and the IPmux-1, IPmux-1E shall not exceed the sum paid to RAD for the purchase of the IPmux-1, IPmux-1E. In no event shall RAD be liable for any indirect, incidental, consequential, special, or exemplary damages or lost profits, even if RAD has been advised of the possibility of such damages.
This Agreement shall be construed and governed in accordance with the laws of the State of Israel.
General Safety Instructions
The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual.
Safety Symbols
This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel.
Warning
Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines.
.
Warning
Protective earth: the marked lug or terminal should be connected to the building protective earth bus.
Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached. Please observe the following precautions:
Before turning on the equipment, make sure that the fiber optic cable is intact and is connected to the transmitter.
Do not attempt to adjust the laser drive current.
Do not use broken or unterminated fiber-optic cables/connectors or look
straight at the laser beam.
The use of optical devices with the equipment will increase eye hazard.
Use of controls, adjustments or performing procedures other than those
specified herein, may result in hazardous radiation exposure.
ATTENTION: The laser beam may be invisible!
Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user.
Handling Energized Products
General Safety Practices
Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist.
Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts.
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is provided on the product, it should be connected to the protective earth at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and cabinets.
Always make the ground connection first and disconnect it last. Do not connect telecommunication cables to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the ground.
Connection of AC Mains
Make sure that the electrical installation complies with local codes.
Always connect the AC plug to a wall socket with a protective ground.
The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A.
Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation.
Connection of DC Mains
Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded.
Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards.
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to qualified service and maintenance personnel.
Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes.
The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A.
Before connecting the DC supply wires, ensure that power is removed form the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position.
A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation.
Connection of Data and Telecommunications Cables
Data and telecommunication interfaces are classified according to their safety status.
The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manual.
Ports Safety Status
V.11, V.28, V.35, V.36, RS-530, X.21, 10 BaseT, 100 BaseT, Unbalanced E1, E2, E3, STM, DS-2, DS-3, S-Interface ISDN, Analog voice E&M
xDSL (without feeding voltage), Balanced E1, T1, Sub E1/T1
FXS (Foreign Exchange Subscriber) TNV-2 Telecommunication Network Voltage-2:
FXO (Foreign Exchange Office), xDSL (with feeding voltage), U-Interface ISDN
SELV Safety Extra Low Voltage:
Ports which do not present a safety hazard. Usually up to 30 VAC or 60 VDC.
TNV-1 Telecommunication Network Voltage-1:
Ports whose normal operating voltage is within the limits of SELV, on which overvoltages from telecommunications networks are possible.
Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are not possible. These ports are not permitted to be directly connected to external telephone and data lines.
TNV-3 Telecommunication Network Voltage-3:
Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are possible.
Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a qualified safety engineer.
Always make sure that the equipment is grounded before connecting telecommunication cables. Do not disconnect the ground connection before disconnecting all telecommunications cables.
Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables. Extra caution should be exercised during thunderstorms.
When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The earthing and bonding of the ground connections should comply with the local codes.
The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between exposed external wires and the AC power lines. In order to reduce the risk, there are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors.
Caution
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords.
Attention
Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure.
Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such cases, a notice will be given in the installation instructions.
Do not attempt to tamper with any carrier-provided equipment or connection hardware.
Electromagnetic Compatibility (EMC)
The equipment is designed and approved to comply with the electromagnetic regulations of major regulatory bodies. The following instructions may enhance the performance of the equipment and will provide better protection against excessive emission and better immunity against disturbances.
A good earth connection is essential. When installing the equipment in a rack, make sure to remove all traces of paint from the mounting points. Use suitable lock-washers and torque. If an external grounding lug is provided, connect it to the earth bus using braided wire as short as possible.
The equipment is designed to comply with EMC requirements when connecting it with unshielded twisted pair (UTP) cables. However, the use of shielded wires is always recommended, especially for high-rate data. In some cases, when unshielded wires are used, ferrite cores should be installed on certain cables. In such cases, special instructions are provided in the manual.
Disconnect all wires which are not in permanent use, such as cables used for one-time configuration.
The compliance of the equipment with the regulations for conducted emission on the data lines is dependent on the cable quality. The emission is tested for UTP with 80 dB longitudinal conversion loss (LCL).
Unless otherwise specified or described in the manual, TNV-1 and TNV-3 ports provide secondary protection against surges on the data lines. Primary protectors should be provided in the building installation.
The equipment is designed to provide adequate protection against electro-static discharge (ESD). However, it is good working practice to use caution when connecting cables terminated with plastic connectors (without a grounded metal hood, such as flat cables) to sensitive data lines. Before connecting such cables, discharge yourself by touching earth ground or wear an ESD preventive wrist strap.
FCC-15 User Information
This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the Installation and Operation manual, may cause harmful interference to the radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Canadian Emission Requirements
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Warning per EN 55022 (CISPR-22)
Warning
Avertissement
Achtung
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user will be required to take adequate measures.
Cet appareil est un appareil de Classe A. Dans un environnement résidentiel, cet appareil peut provoquer des brouillages radioélectriques. Dans ces cas, il peut être demandé à l’utilisateur de prendre les mesures appropriées.
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkströrungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.
Declaration of Conformity
Manufacturer's Name: RAD Data Communications Ltd.
Manufacturer's Address: 24 Raoul Wallenberg St.
Tel Aviv 69719
Israel
declares that the product:
Product Name: IPmux-1, IPmux-1E
conforms to the following standard(s) or other normative document(s):
EMC: EN 55022 (1994) Limits and methods of measurement of radio disturbance
characteristics of information technology equipment.
EN 50024 (1998) Information technology equipment –Immunity
characteristics – Limits and methods of measurement.
Safety: EN 60950/A4 (1996) Safety of information technology equipment, including
electrical business equipment.
Supplementary Information:
The products herewith comply with the requirements of the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC and the R & TTE directive 99/5/EC for wired equipment. The products were tested in a typical configuration.
Tel Aviv, March 18, 2001
Haim Karshen VP Quality
European Contact: RAD Data Communications GmbH, Otto-Hahn-Str. 28-30, 85521 Ottobrunn-Riemerling, Germany
Preface
Foreword
This manual describes the technical characteristics, applications, installation and operation of IPmux-1 and IPmux-1E. In this manual the products will be referred to as IPmux-1/1E.
Manual Organization
This manual is organized as follows:
Chapter 1. Introduction
presents the main features versions, applications, functional description, and lists the technical specifications of IPmux-1/1E.
Chapter 2. Installation
provides detailed installation and operation instructions for IPmux-1/1E.
Chapter 3. Operation
provides general instructions for getting started, managing IPmux-1/1E by means of terminals and Telnet hosts, and provides typical configuration procedures.
Chapter 4. Tests and Diagnostics
describes the diagnostic and performance monitoring functions supported by IPmux-1/1E.
Appendix A. Boot Sequence for Downloading Software
provides instructions for the installation of new software releases.
Appendix B. Telnet
details management by Telnet.
Appendix C. SNMP Management
describes the SNMP and IP environments, and provides background information regarding the handling of management traffic.
Appendix D. TFTP Download Procedures
details management by Telnet.
Appendix E. Parameters and Screens
describes the configuration screens and parameters.
Conventions
Note
Caution
Warning
A note draws attention to a general rule for a procedure, or to exceptions to a rule.
A caution warns of possible damage to the equipment if a procedure is not followed correctly.
A warning alerts to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the equipment. If these instructions are not followed exactly, possible bodily injury may occur.

Quick Start Guide

1. Setting Jumpers - IPmux-1E ISDN Version Only
The IPmux-1E ISDN version contains jumpers for Phantom Feed. Other IPmux-1/1E models do not require jumper configuration.
To set the IPmux-1E ISDN-S module jumpers:
If necessary, change the settings in accordance with the specific requirements of your application:
ENA – enable Phantom Feed
DIS – disable Phantom Feed.
The Phantom Feed ENA/DIS setting influences the IPmux-1E BRI operation mode. When Phantom Feed is disabled, the S-interface can be configured (through software) to the TE or NT mode. When Phantom Feed is enabled, only the NT mode is possible.
2. IPmux-1/1E Operation
To operate the IPmux-1/1E:
1. Power up the IPmux-1/1E unit.
2. Connect an ASCII terminal to IPmux-1/1E control port (IPmux-1/1E default setting: 19200, N, 8, 1).
3. Verify IPmux-1/1E startup by one of the following:
From the ASCII terminal, verify that the Self-Test has ended successfully.
Check the RDY LED on the on the left side of the front panel of the unit.
4. Connect the Ethernet link cable to the network port (connect an Ethernet link to the user port if the model includes one) and check the Sync LED.
5. Connect TDM cables to the TDM port.
6. Log in to the system software.
IPmux-1/1E Operation 1
Quick Start Guide IPmux-1/1E Installation and Operation Manual
3. IPmux-1/1E Configuration
General
IPmux-1/1E configuration is performed from the ASCII terminal connected to the Control port. The system software is divided into three functions:
System: General IPmux-1/1E system information.
Configuration: Performs all configuration functions
Performance Monitoring: Monitors overall performance
Note
Configuration
Perform the following configuration procedures in the order given.
1. From the Main menu, type 2 (Configuration), 1 (General Configuration) 1 (Host IP). Enter the Host IP parameters.
2. For IPmux-1
: From the Main menu, type 2 (Configuration), 2 (E1/T1)
Configuration. Modify as necessary.
For IPmux-1E
: From the Main menu, type 2 (Configuration), 2 (ISDN or
Analog Configuration). Modify as necessary.
3. For IPmux-1
: If you selected a framed line type in the E1/T1 configuration, then the from the Main menu, type 2 (Configuration), 5 (DSO Bundle Configuration). Define timeslots.
4. From the Main menu, type 2 Configuration, 4 LAN Configuration. Modify as necessary.
5. From the Main menu, type 2 (Configuration), 3 (Connection Configuration). Select the connection mode and enter the other parameters as necessary.
2 IPmux-1/1E Configuration

Contents

Chapter 1. Introduction
1.1 Overview..................................................................................................................... 1-1
Versions................................................................................................................................ 1-1
Applications.......................................................................................................................... 1-2
Features................................................................................................................................ 1-5
1.2 Physical Description..................................................................................................... 1-8
Front Panel........................................................................................................................... 1-9
Rear Panel ............................................................................................................................ 1-9
1.3 Functional Description................................................................................................. 1-9
Operation Modes ...............................................................................................................1-10
Timeslot Assignment in a Bundle......................................................................................... 1-12
Testing................................................................................................................................ 1-13
Timing Modes..................................................................................................................... 1-13
Network Timing Schemes ...................................................................................................1-14
Frame Format .....................................................................................................................1-16
Packet Delay Variation........................................................................................................ 1-18
PDVT (Jitter) Buffer ............................................................................................................. 1-19
Ethernet Throughput...........................................................................................................1-20
Round Trip Delay ............................................................................................................... 1-22
Reorder and Duplication of Ethernet Frames .......................................................................1-23
OAM Connectivity.............................................................................................................. 1-24
End-to-End Alarm Generation .............................................................................................1-24
VLAN Traffic Behavior ........................................................................................................1-25
Ethernet User Port ..............................................................................................................1-26
DHCP ................................................................................................................................1-32
1.4 Technical Specifications............................................................................................. 1-33
Chapter 2. Installation
2.1 Introduction................................................................................................................. 2-1
2.2 Site Requirements and Prerequisites ............................................................................ 2-2
2.3 Package Contents ........................................................................................................2-2
Power Cord ..........................................................................................................................2-2
2.4 Equipment Needed ..................................................................................................... 2-3
2.5 Installation and Setup .................................................................................................. 2-3
Setting Jumpers.....................................................................................................................2-3
Connecting Interfaces and Cables..........................................................................................2-5
Connecting the Power ........................................................................................................2-10
Chapter 3. Operation
3.1 Front Panel Controls, Connectors, and Indicators......................................................... 3-1
3.2 Operating Instructions ................................................................................................. 3-4
Turning IPmux-1/1E On........................................................................................................ 3-4
Login ....................................................................................................................................3-5
Turning IPmux-1/1E Off........................................................................................................ 3-5
3.3 Getting Started............................................................................................................. 3-6
IPmux-1/1E Installation and Operation Manual i
Table of Contents
3.4 Overview of Menu Operations .................................................................................... 3-6
Navigating ............................................................................................................................3-6
Main Menu.........................................................................................................................3-12
System Menu...................................................................................................................... 3-13
Setting IPmux-1/1E Configuration Options...........................................................................3-14
Performance Monitoring ..................................................................................................... 3-16
Chapter 4. Troubleshooting and Diagnostics
4.1 Error Detection............................................................................................................ 4-1
Using Front Panel LEDs.........................................................................................................4-1
Working with the Alarm Buffer.............................................................................................. 4-1
4.2 Troubleshooting........................................................................................................... 4-4
4.3 Performance Monitoring and Troubleshooting Statistics ............................................... 4-5
E1/T1 Statistics......................................................................................................................4-5
LAN Statistics...................................................................................................................... 4-12
Bundle Connection Statistics ...............................................................................................4-22
4.4 Diagnostic Tests ......................................................................................................... 4-27
E1/T1..................................................................................................................................4-27
ISDN BRI............................................................................................................................ 4-28
FXS/FXO/E&M ....................................................................................................................4-28
4.5 Frequently Asked Questions ...................................................................................... 4-29
Appendix A. Boot Sequence for Downloading Software
Appendix B. Telnet
Appendix C. SNMP Management
Appendix D. TFTP Download Procedures
Appendix E. Configuration Menus
Index
List of Figures
1-1. Multiplexing Voice and Data over an IP/Ethernet Link ........................................................... 1-2
1-2. E1/T1 Circuit Extension over an IP/Ethernet Network............................................................. 1-3
1-3. Analog Voice Application ...................................................................................................... 1-3
1-4. Digital ISDN Application (V5.1 Concentration of Remote BRIs) ............................................. 1-4
1-5. Extending ISDN BRI Ports of a Small Office ........................................................................... 1-4
1-6. Ethernet-based Multi-tenant Application with Voice and Data Integrated Access ................... 1-5
1-7. IPmux-1/1E 3-Dimensional View ............................................................................................ 1-9
1-8. IPmux-1 E1/T1 Point-to-Point Application ............................................................................. 1-9
1-9. Grooming of Timeslots from Remote Sites into a Single E1/T1 Port at Central Site............... 1-10
1-10. Timeslot Assignment in a Bundle, for IPmux-1E/ISDN........................................................ 1-12
1-11. IPmux-1 in Loopback Timing Mode................................................................................... 1-14
1-12. IPmux-1 in External Clock Mode ....................................................................................... 1-15
1-13. IPmux-1 in Adaptive Timing Mode .................................................................................... 1-15
ii IPmux-1/1E Installation and Operation Manual
Table of Contents
1-14. IPmux-1E in Adaptive Timing Mode .................................................................................. 1-15
1-15. TDMoIP Frame Structure................................................................................................... 1-16
1-16. VLAN Tag Format (802.1p&q) ........................................................................................... 1-18
1-17. Packet Delay Variation ...................................................................................................... 1-19
1-18. IPmux-1/1E with Ethernet User Port .................................................................................. 1-26
2-1. IPmux-1E ISDN-S Jumpers..................................................................................................... 2-4
2-2. IPmux-1 Front Panel.............................................................................................................. 2-5
2-3. IPmux-1 Front Panel for Two Ethernet Ports .......................................................................... 2-5
2-4. IPmux-1 Rear Panel............................................................................................................... 2-5
2-5. IPmux-1 Rear Panel for Two Ethernet Ports ........................................................................... 2-5
2-6. IPmux-1E Front Panel............................................................................................................ 2-6
2-7. IPmux-1E Front Panel for Two Ethernet Ports ........................................................................ 2-6
2-8. IPmux-1E Rear Panel (ISDN BRI Option) ............................................................................... 2-6
2-9. IPmux-1E Rear Panel (ISDN BRI Option) for Two Ethernet Ports............................................ 2-6
2-10. External Clock Port Pinout ................................................................................................... 2-9
3-1. IPmux-1 Front Panel LEDs ..................................................................................................... 3-2
3-2. IPmux-1 Rear Panel Switch.................................................................................................... 3-2
3-3. IPmux-1E Front Panel Indicators ............................................................................................ 3-3
3-4. IPmux-1E Back Panel Indicators ............................................................................................ 3-3
3-5. IPmux-1 (E1/T1) Terminal Menu Tree.................................................................................... 3-7
3-6. IPmux-1E ISDN-S Terminal Menu Tree ................................................................................. 3-8
3-7. IPmux-1E FXS/FXO/E&M Terminal Menu Tree....................................................................... 3-9
3-8. IPmux-1/1E Connection Configuration Menu Tree for Static Mode...................................... 3-10
3-9. IPmux-1E Connection Configuration Menu Tree for Dynamic CAS Mode............................ 3-11
3-10. IPmux-1E Connection Configuration Menu Tree for CESoIP Mode .................................... 3-12
3-11. IPmux-1/1E Main Menu .................................................................................................... 3-13
3-12. IPmux-1/1E System Menu ................................................................................................. 3-14
3-13. IPmux-1/1E Configuration Menu ....................................................................................... 3-14
3-14. IPmux-1E ISDN-S Configuration Menu .............................................................................. 3-15
3-15. IPmux-1E FXS/FXO/E&M Configuration Menu ................................................................... 3-15
3-16. Performance Monitoring Menu for IPmux-1 ...................................................................... 3-16
3-17. Performance Monitoring Menu for IPmux-1E ISDN-S ........................................................ 3-16
3-18. Performance Monitoring Menu for IPmux-1E FXS/FXO/E&M ............................................. 3-17
4-1. E1 Statistics............................................................................................................................ 4-6
4-2. LAN Statistics....................................................................................................................... 4-12
4-3. LAN Statistics....................................................................................................................... 4-17
4-4. Bundle Connection Status ................................................................................................... 4-22
4-5. IPmux-1 External Loop ........................................................................................................ 4-27
4-6. IPmux-1 Internal Loop......................................................................................................... 4-27
4-7. IPmux-1E/ISDN External Loop ............................................................................................. 4-28
4-8. IPmux-1E/ISDN Internal Loop ............................................................................................. 4-28
IPmux-1/1E Installation and Operation Manual iii
Table of Contents
List of Tables
1-1. Fiber Options ........................................................................................................................ 1-7
1-2. Ethernet Frame Structure..................................................................................................... 1-17
1-3. UDP Ports Definition........................................................................................................... 1-18
1-4. VLAN Check for Packets that are Received by IPmux-1/1E .................................................. 1-25
1-5. VLAN Check for Packets that are Sent by IPmux-1/1E.......................................................... 1-25
1-6. Switch Behavior .................................................................................................................. 1-27
1-7. Basic Mode ......................................................................................................................... 1-27
1-8. User Tagged Mode .............................................................................................................. 1-28
1-9. User Untagged Mode .......................................................................................................... 1-29
1-10. Rate Mode ........................................................................................................................ 1-30
1-11. Rate+User Tagged Mode .................................................................................................. 1-31
1-12. Rate+User Untagged Mode .............................................................................................. 1-32
2-1. E1/T1 Port Connectors Pinout................................................................................................ 2-7
2-2. Ethernet Port Pinout .............................................................................................................. 2-7
2-3. Control Port Pinout ............................................................................................................... 2-8
2-4. ISDN-S-Interface Pin Assignments.......................................................................................... 2-8
2-5. E&M Interface Pin Assignments for RJ-11............................................................................... 2-9
2-6. FXS/FXO Interface Pin Assignments for RJ-11 ......................................................................... 2-9
2-7. External Clock Port Pinout ................................................................................................... 2-10
3-1. IPmux-1 System Indicators and Switches ............................................................................... 3-2
3-2. IPmux-1E (BRI/FXS/FXO/E&M) System Indicators and Switches.............................................. 3-3
3-3. IPmux-1/1E Main Menu Options ......................................................................................... 3-13
3-4. IPmux-1/1E System Menu Options ...................................................................................... 3-13
3-5. Configuration Options ......................................................................................................... 3-15
3-6. Performance Monitoring Menu Options .............................................................................. 3-17
4-1. Event Types........................................................................................................................... 4-2
4-2. IPmux-1 Troubleshooting Chart ............................................................................................. 4-4
4-3. E1/T1 Alarms ......................................................................................................................... 4-8
4-4. LAN Statistics Parameters..................................................................................................... 4-14
4-5. LAN Statistics Parameters..................................................................................................... 4-19
4-6. Bundle Connection Status Parameters ................................................................................. 4-23
iv IPmux-1/1E Installation and Operation Manual

Chapter 1 Introduction

1.1 Overview
IPmux-1 and IPmux-1E (referred to as IPmux-1/1E) offer a solution for extending traditional E1/T1, ISDN, or POTS TDM services transparently over Packet Switched Networks (PSNs) such as IP, Ethernet, and MPLS networks. The device converts the data stream coming from its user ports into configurable sized IP packets that are extended over the Fast Ethernet Network port, and vice versa. IPmux-1/1E offers end-to-end synchronization for voice/leased line applications. IPmux-1/1E also features a Fast Ethernet user port for data (Ethernet) connectivity to the IP/Ethernet network. Management is performed locally by a terminal, or remotely via Telnet or SNMP.

Versions

IPmux-1/1E offers:
E1/T1 service in IPMux-1 or E1/T1 with echo canceling in IPMux-1E
ISDN BRI (‘S’) extension in IPmux-1E
Analog extension (FXS, FXO, or E&M) with optional echo canceling in
IPmux-1E.
The IPmux family implements TDMoIP technology to carry TDM transport over IP. IPmux-1E ISDN BRI channels are transported as TDM timeslots, while the analog FXS/FXO/E&M channels are digitized and carried as fractional E1/T1 with CAS.
IPmux-1 with E1 interface
Balanced line with an RJ-45 (120) connector Unbalanced line with an RJ-45 (75) connector (RJ-45 to BNC cable
adapter is supplied)
IPmux-1 with T1 interface – Balanced with an RJ-45 connector
IPmux-1E with ISDN BRI interface – 4 ISDN ‘S’ RJ-45 connectors
IPmux-1E with FXS Interface – 4 Analog ‘FXS’ RJ-11 connectors, and optional
echo canceller
IPmux-1E with FXO interface – 4 Analog ‘FXO’ RJ-11 connectors, and optional echo canceller
IPmux-1E with E&M interface – 4 Analog ‘E&M RJ-45 connectors, and optional echo canceller

Overview 1-1