Circuit Specialists TC-V2.12k, CSI-TC1 User Manual

Multi-function Tester (TC-V2.12k)
1 Overview
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
① - 160x128 TFT display ② - Multi function key ③ - Transistor test area ④ - Zener Diode test area ⑤ - IR receiver window ⑥ - Micro USB Charging Interface ⑦ - Charge indicator LED
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 14,25 Page 14 , Total25
1.2 Features
TC-V2.12k is a TFT graphic display Multifunction Tester. Transistor Tester
- Automatic detection of NPN and PNP bipolar transistors, N-channel and P-channel
MOSFETs, JFETs, diodes (including double diodes), N- and P-IGBTs, resistors (including potentiometers), inductors, capacitors, thyristors, triacs and battery (0.1-4.5V)
- Automatic detection of zener diode(0.01-30V)
- Self test with automatic calibration
IR decoder
- Support Hitachi IR coding
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
- IR waveform display
- Infrared receiving instruction
Other
- Measurement results using TFT graphic display(160x128)
- One key operation
- Auto Power Off(Timeout Settable)
- Built-in high capacity rechargeable Li-ion Battery
- Li-ion Battery voltage detection
- Support Chinese and English
Warning: Built-in Li-ion Battery, it is strictly prohibited the tester immersed in water,
or near a heat source!
Warning: For your personal safety, please strictly comply with the use of Li-ion
Battery specifications and precautions!
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 15 ,25 Page 15 , Total25
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
2 Operating Instructions
2.1 Key operational definitions
Multi-function key has two actions:
Short press: Press the key and not less than 10 ms, release key within 1.5 seconds Long press: Press the key more than 1.5 seconds
2.2 Power on
In the power off state, short press the multifunction key, the tester is turned on and
automatically measured.
Power on & measurement interface
2.3 Detect transistor
In the power off state or the test is completed, put the test element into the transistor test area of test seat, and press the locking handle, short press the multifunction key, the tester automatically measure, graphical display of measurement results when testing is complete.
Warning: Always be sure to DISCHARGE capacitors before connecting them to the
tester! The tester may be damaged before you have switched it on!
Warning: We do not recommend using the tester to measure the battery! The battery
voltage must be less than 4.5V, otherwise the tester may be damaged!
Component placement
Test seat are divided into transistors and zener diode test area, detailed in 1.1 Description.
No, unknown, or damaged part
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 16 ,25 Page 16 , Total25
Battery
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
BJT(Bipolar Junction Transistor)
Diode
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 17 ,25 Page 17 , Total25
2 Diodes
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
MOSFET
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 18 ,25 Page 18 , Total25
Thyristor
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
Triac
Capacitor
Resistor
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 19 ,25 Page 19 , Total25
Inductor
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
2.4 Selftest
Short all three Probes, short press the multifunction key, the tester will be automatically calibrates itself.
In addition to the calibration process when prompted disconnect external wiring short(Isolate the probes), without the need for other operations.
Calibrating
Isolate the probes
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 20 ,25 Page 20 , Total25
Selftest End
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
Warning: Do not carry out other operations in the calibration process, so as not to
affect the calibration accuracy!
2.5 Detect Zener diode
In the power off state or the detection is completed, put the Zener diode into the Zener diode test area of test seat, and press the locking handle, short press the multifunction key, the tester automatically measure, graphical display of measurement results when testing is complete.
Warning: Do not put the component into transistor test area, otherwise it is
impossible to test zener diode!
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 21 ,25 Page 21 , Total25
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
2.6 IR decoder
After the component detection is completed, the infrared remote control at the tester "IR" test hole, press the remote control key, the tester will be display the user code & data code and the corresponding infrared waveform after the successful decoding.
If decoding failure, the tester cannot display the user code and data code.
The dot at the top right corner to indicate whether it has received the remote control infrared data, red represents infrared data is being received, blue represents decoding success.
InformationThe IR decoder only support Hitachi IR format.
2.7 Power off
The Multifunction Tester with automatic shutdown and manual shutdown.
Automatic shutdown
When the component detection completed or IR decoding completed and after reaching the automatically shut down time, the tester automatically shut down. Automatic shutdown time can be set by the hardware jumpers, timeout support for 10s, 15s, 20s and 25s. Factory set to 20s.
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 22 ,25 Page 22 , Total25
Warning: Adjust the automatic shutdown time required to open the housing, and use
an electric soldering iron solder the jumpers.
Attention:Please do ESD protection!
Manual shutdown
Long press the multifunction key to force a shutdown in any state, while the measuring element is included.
2.8 Built-in Li-ion Battery voltage measurement
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
The built-in Li-ion Battery voltage is measured before detection, when the battery voltage is less than 3.0V will force shutdown, then please charging.
2.9 Charging the Battery
The tester has a standard Micro USB interface, please use an external 5V power supply or USB power charging.
InformationRed LED indicates is charging, green LED indicates charging is
complete.
Warning: Charging input voltage up to 6V, do not exceed the top voltage, or it will
damage the tester, and could cause the battery to explode!
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 23 ,25 Page 23 , Total25
多功能测试仪(TC-V2.12k Multi-function Tester (TC-V2.12k)
3 Performance Parameters
Multifunction Tester can automatically identify elements and automatic detection of pin layout, and automatic switching range.
The main performance parameters are as follows:
Component Range Parameter Description
hFE(DC Current Gain), Ube(Base-Emitter Voltage), Ic(Collector Current), Iceo(Collector
BJT -
Diode
Forward Voltage <4.50V
Double Diodes Forward Voltage
0.01-4.50V (Transistor test area)
Zener Diode
0.01-30V (Zener Diode test area)
JFET
MOSFET
IGBT
MOSFET
Thyristor
Triac
Igt(Gate trigger current )<6mA
Capacitor 25pF-100mF
Resistor
0.01-50MΩ
Inductor 0.01mH-20H
Battery 0.1-4.5V Voltage, Battery Polarity
Cut-off Current (IB=0)), Ices(Collector short Current), Uf(Forward Voltage of protecting diode)
Forward Voltage, Diode Capacitance, Ir(Reverse Current) ②
Forward Voltage, Reverse Voltage
Reverse Voltage
Cg(Gate Capacitance), Id(Drain Current) at Vgs(Gate to Source Threshold Voltag), Uf(Forward Voltage of protecting diode) ④ Id(Drain Current) at Vgs(Gate to Source Threshold Voltag), Uf(Forward Voltage of protecting diode)
Vt(Gate to Source Threshold Voltag), Cg(Gate Capacitance), Rds(Drain to Source On Resistance), Uf(Forward Voltage of protecting diode) ④
Gate trigger voltage
Capacitance, ESR(Equivalent Series Resistance), Vloss
Resistance Inductance, DC Resistance ⑤
Note: Iceo, Ices, Uf displayed only when effective
Note: Diode Capacitance, Ir(Reverse Current) displayed only when effective
Note: Displayed only when has protecting diode
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 24 ,25 Page 24 , Total25
多功能测试仪(TC-V2.12k
Note: ESR, Vloss displayed only when effective
Note: Measurement of inductors with resistance below 2100Ω
Multi-function Tester (TC-V2.12k)
4 FAQ
Question Cause Solution
Cannot power on
Inaccurate measurements
Built-in Li-ion Battery is dead Inaccurate calibration parameters
5 Packing List
Tester x1, User’s manual x1.
Charging the Li-ion Battery, charging methods see section 2.9
Please re-calibration, see section 2.4
2017-4-62015-8-8 版权所有,侵权必究 All rights reserved 25 ,25 Page 25 , Total25
Loading...