Chicago Faucet MeterMix 4, 3300 Installation Manual

0 (0)

METERMIX™ 4" CENTERSET FAUCET

Installation Instructions

NOTE

Pressurized plumbing fixtures shall be installed in accordance with manufacturer’s recommendations. The supply piping to these devices shall be securely anchored to the building structure to prevent installed device from unnecessary movement when operated by the user. Care shall be exercised when installing the device to prevent marring the exposed significant surface.

Copyrights

© 2004 Geberit. All rights reserved. The information in this manual is subject to change without notice.

Notice to Installers

Please leave this manual with the facility manager after completing the faucet installation.

This document contains information necessary for routine maintenance and servicing.

T-319

 

 

 

 

 

 

 

 

ADA Compliant

 

 

MeterMix Faucet

Installation Instructions

PRODUCT OVERVIEW

The MeterMix™ faucet provides the water savings of a metering faucet combined with the convenience of temperature adjustment.

METERMIX FEATURES

MVP™ Metering Cartridge has proven performance and is backed by a 5-year warranty

Two in-line check/screen assemblies

Vandal resistant .5 GPM spray outlet

Adjustable timing

Variable temperature control

Concealed adjustable temperature limit stop

Vandal resistant, ADA compliant handle

SAFETY INFORMATION

Read this entire instruction sheet to ensure proper installation.

Compliance and conformity to local codes and

ordinances is the responsibility of the installer.

TECHNICAL SUPPORT

For additional technical assistance, call

800 / TEC-TRUE (800-832-8783) or visit our website at www.chicagofaucets.com.

The MeterMix Faucet consists of:

 

 

 

1.

Handle Button

 

 

1

2.

Screw (assembled)

 

2

 

3.

Handle (assembled)

 

3

 

4.

Actuator Assembly

 

 

9

5.

Gasket

 

4

10

6.

MVP Cartridge

 

 

 

 

11

7.

Filter Basket

 

5

 

 

 

 

8.

Faucet Body

 

6

12

9.

Screw, Mixing Stem

 

 

 

 

 

10.

Gear

 

7

13

 

 

11.

O-Ring, Mixing Stem (Qty. 2)

 

 

14

12.

Mixing stem

 

 

 

 

 

13.

Screw (Qty. 2)

15

 

8

14.

Bracket

 

 

 

 

15.

Outlet

23

 

 

16.

Check Cartridge (Qty. 2)

 

16

19

 

17.

C-Clip (Qty. 2)

 

17

 

 

18

Filter/Screen (Qty. 2)

20

 

18

19.

Plastic Spacer (Qty. 2)

21

 

 

20.

Basin Washer (Qty. 2)

 

 

22

 

 

21.

Locknut (Qty. 2)

 

 

 

 

 

22.

Supply Nut (Qty. 2)

 

 

 

23.

Vandal Resistant Outlet Key

 

 

 

2

Chicago Faucet MeterMix 4, 3300 Installation  Manual

MeterMix Faucet

Installation Instructions

INSTALLATION

1. Turn off water supply to existing faucet and remove faucet, if necessary.

2. Clean faucet basin and clear away debris.

3. Mount the spout to top of base. Install the plastic spacer (if required), basin washers and locknuts to the faucet from underneath the base. Securely tighten the locknuts.

NOTE: Use silicon sealant for porous stone or plumbers putty as recommended by counter manufacturer.

Do not use a wrench on spout or inlet tubes. Flush lines before connecting supply tube to faucet. Faucet has inlet screens that can clog if not flushed.

4. Install the supply nuts to the water inlet tubes and connect tubes to faucet. Tighten connections securely.

5. Flush installed faucet before installing outlet.

6. Install outlet using key supplied. Do not overtighten.

7. Make all hot limit stop & timing adjustments (see page 4) prior to performing step 8.

8. Install handle button.