Carrier SYSTXCCUID01-V Owner's Manual

4.7 (3)

TM

Infinity Control

Homeowner’s

Guide

The New Feeling of Comfort

CONGRATULATIONS!

Your decision to choose the

Carrier Infinity Control puts

you in a select group of home-

owners who understand the

value of precise comfort control

and appreciate the simplicity

of an easy-to-use, intuitive,

user interface.

We sincerely appreciate you

putting your trust in Carrier.

Carrier has been delivering

the finest indoor comfort

equipment since 1904. Your

new Infinity Control offers yet

another example of the high

quality comfort technology for

which we are recognized.

Please take a few moments to

review this manual…set up a

comfort schedule that makes

sense for your lifestyle…then

relax and enjoy the comfort!

Temperature/Humidity Button

displays current indoor humidity

or outside temperature.

Room Temperature

Day & Time

Time Period displays the com-

fort schedule’s active period.

Left Button provides accessory

status.

Hold Button maintains desired

temperature indefinitely.

Time (+\-) Button

Schedule Button used to

access and exit the comfort

schedule.

Vacation Button

activates/deactivates vacation

comfort settings.

Scroll Button used to move

up and down the screen

during scheduling and setup.

Carrier SYSTXCCUID01-V Owner's Manual

Fan Setting

Fan Button chooses “high,”

“medium,” “low,” or “auto”

fan mode.

Desired Heating/Cooling

Temperature

Right Button provides

system status.

Heat Button selects heating

operation.

Cool Button selects cooling

operation.

Heat/Cool LEDs indicate

heating or cooling operation.

Temp (+\-) Button

Off Button turns the system

on and off.

Advanced Setup Button

provides access to

customizable features.

Basic Setup Button provides

access to current day, time

and desired humidity level.

TABLE OF CONTENTS

QUICK GUIDE INSTRUCTIONS . . .2

BASIC SETUP . . . . . . . . . . . . . . . . . .6

Set Day, Time & Humidity . . . . . .6

NORMAL OPERATION . . . . . . . . . .7

Turn System On/Off . . . . . . . . . . . .7

Heating . . . . . . . . . . . . . . . . . . . . . .7

Auxiliary Heat . . . . . . . . . . . . . . . . .7

Emergency Heat . . . . . . . . . . . . . .7

Cooling . . . . . . . . . . . . . . . . . . . . . .8

Auto . . . . . . . . . . . . . . . . . . . . . . .9

Adjust Current Temperature . . .9

Adjust Heating Temperature .9

Adjust Cooling Temperature 10

Adjust Fan Speed . . . . . . . . . . . .10

Hold Current Temperature . . . .10

Vacation Function & Settings . .11

Check System Status

(Right Button) . . . . . . . . . . . . . . . . . . . .12

Accessory Status (Left Button) 12

Resetting Accessory Usage

Indicator . . . . . . . . . . . . . . . . . . . . .13

Accessory Maintenance Pop-Up

Messages . . . . . . . . . . . . . . . . . . . . . .13

Service Pop-Up Messages . . . . .14

Keyboard Lock-out . . . . . . . . . . .15

1

PROGRAMMABLE FEATURES,

SETUP & OPERATION . . . . . . . . . .16

Backlighting . . . . . . . . . . . . . . . . . .16

Determining Your Comfort

Schedule . . . . . . . . . . . . . . . . . . . . . . . .16

Programming Your Comfort

Schedule . . . . . . . . . . . . . . . . . . . . .17

One Schedule for All Days . . . .18

Weekdays Schedule . . . . . . . . . .19

Weekend Schedule . . . . . . . . . .20

Daily Schedule . . . . . . . . . . . . . . .21

Copying a Schedule . . . . . . . . .22

Programming Fan Speed . . . .23

VENTILATION FEATURES,

SETUP & OPERATION . . . . . . . . . .24

Fresh Air Ventilation . . . . . . . . . .24

ADVANCED SETUP . . . . . . . . . . . .25

Accessory Maintenance

Reminders . . . . . . . . . . . . . . . . . . .25

Lighting . . . . . . . . . . . . . . . . . . . . . .26

Heating Humidity . . . . . . . . . . . .27

Cooling Humidity . . . . . . . . . . . .28

Vacation . . . . . . . . . . . . . . . . . . . .29

GLOSSARY . . . . . . . . . . . . . . . . . . .31

QUICK GUIDE INSTRUCTIONS

2

 

 

This guide provides the basic operations for setting up and operating your InfinityControl.

Set Day, Time & Desired Humidity

1 Flip down the door at the base of the

InfinityControl.

2 Press the BASIC button.

3 Adjust the highlighted HOUR setting

using the TIME (+\-) button.

4Press SCROLL to highlight MINUTE.

5Adjust the MINUTE setting using the TIME (+\-) button.

6Press SCROLL to highlight DAY.

7Adjust the current DAY setting, using the TIME (+\-) button,

until the correct day is displayed.

8Press SCROLL to highlight HUMIDITY.

9Press the red HEAT button to set the heating humidity.

10Adjust the desired heating humidity using either (+\-)

button.

11Press the blue COOL button to set the cooling humidity.

12Adjust the desired cooling humidity using either (+\-)

button.

13Press BASIC or close the door to exit.

Adjust Heating Temperature

1Press the red HEAT button. Heating is confirmed when the

red LED adjacent to the red HEAT button is lit.

QUICK GUIDE INSTRUCTIONS

3

 

 

2Use the TEMP (+\-) button to select your desired temperature,

which will be displayed on the lower right. An override time will

be displayed on the lower left. Please note an override time will

not appear if programming has been turned off.

3You can change the override time in 15-minute increments by

pressing the TIME (+\-) button until the desired override time is

selected.

- OR -

Press the HOLD button to override the

schedule indefinitely.

Adjust Cooling Temperature

1Press the blue COOL button. Cooling is confirmed when

the blue LED adjacent to the blue CL button is lit.

2Use the TEMP (+\-) button to select your desired tempera-

ture, which will be displayed on the lower right. An override

time will be displayed on the lower left. Please note an

override time will not appear if programming has been

turned off.

3You can change the override time to 15-minute increments

by pressing the TIME (+\-) button until the desired override

time is selected.

- OR -

Press the HOLD button to override the schedule indefinitely.

Quick Programming Instructions

These instructions will guide you through creating one comfort schedule that will repeat every day. For more details on programming, or to create customized schedules for the week,

QUICK GUIDE INSTRUCTIONS

4

 

 

weekend, or each day, refer to PROGRAMMABLE FEATURES, SETUP & OPERATION on pages 16 - 23 of this manual.

One Schedule for All Days

1 Flip down the door at the bottom of the

control.

2 Press the SCHEDULE button.

3 Press either the LEFT or RIGHT button

repeatedly until “ALLDAYS” is displayed.

4The WAKE time period will be highlighted. Set the start time

for this time period using the TIME (+/-) button.

5Press the red HEAT button. Heating temperature will begin

flashing.

6Set the heating temperature using the TEMP (+\-) button.

7Press the blue COOL button. Cooling temperature will

begin flashing.

8Set the cooling temperature using the TEMP (+\-) button.

9Set the remaining periods, “DAY,” “EVENING,” AND “SLEEP”

by using the SCROLL button to select a time period, then

follow steps 5 – 9 to select temperature and time settings.

10Exit the scheduling mode by either closing the door or

pressing the SCHEDULE button.

QUICK GUIDE INSTRUCTIONS

5

 

 

Pop-up Messages

Your InfinityControl provides important and useful maintenance

and service reminders via pop-up messages on the display.

Accessory Maintenance Reminders: An accessory reminder lets

you know when it’s time for maintenance of your air filter, humidifier

pad, UV lamp or ventilator. When an accessory reminder pop-up

message appears, perform the accessory maintenance yourself

OR contact your dealer/contractor.

Service Reminders: When a service reminder pop-up message

appears, contact your dealer/contractor.

See ACCESSORY MAINTENANCE OR SERVICE POP-UP MESSAGES

on page 13 - 14 in this manual for additional information on service

and maintenance reminders.

BASIC SETUP

6

 

 

Set Day, Time & Desired Humidity

1Flip down the door at the base of the InfinityControl.

2Press the BASIC button.

3Adjust the highlighted HOUR setting

using the TIME (+\-) button.

4 Press SCROLL to highlight MINUTE.

5 Adjust the MINUTE setting using the TIME

(+\-) button.

6 Press SCROLL to highlight DAY.

7Adjust the current DAY setting, using the TIME (+\-) button,

until the correct day is displayed.

8Press SCROLL to highlight HUMIDITY.

9Press the red HEAT button to set the heating humidity.

10Adjust the desired heating humidity using either (+/-) button.

11Press the blue COOL button to set the cooling humidity.

12Adjust the desired cooling humidity using either (+/-) button.

13If a ventilator has been installed, press scroll to highlight

FRESH AIR.

14Adjust your desired FRESH AIR setting using the TEMP (+/-)

button. For a description of fresh air settings, see FRESH AIR

VENTILATION on page 24 in this manual.

15Press the BASIC button to exit.

- OR -

If you need to readjust one of your settings, use the SCROLL

button to highlight the desired setting, then make your changes.

16Close the door.

NOTE: You can exit at any time. When exiting, you will be prompted to save changes if you have made any. Select“YES” to save your changes, “NO” to revert back to previous settings.

NORMAL OPERATION

7

 

 

Turn System On/Off

The OFF button is used to turn the system both on and off.

Heating

To select heating, press the red HEAT button.

Heating is confirmed when the red LED adja-

cent to the red HEAT button is lit. Heating is

operating when the red LED is gradually puls-

ing on and off. (The LEDs can be turned off.

For details, see ADVANCED SETUP – LIGHT-

ING on page 26.) The heating temperature will

appear in the lower right screen with the text,

“HEAT AT.”

Auxiliary Heat

Auxiliary heat is staged electric heating included with many heat

pump systems. Auxiliary heat is automatically activated by the sys-

tem when it’s too cold for the heat pump to effectively heat your

home. Auxiliary heat operation is confirmed when the red LED

adjacent to the red HEAT button is lit, gradually pulsing on, then

off. (The LEDs can be turned off. For details, see ADVANCED

SETUP – LIGHTING on page 26.) The text, “AUXILIARY HEAT

ACTIVE” will appear below the room temperature.

Emergency Heat

Emergency heat is staged electric heating included with many

heat pump systems. Emergency heat is activated either when the

heat pump has malfunctioned and heating is required, or when

the homeowner manually activates emergency heat. Emergency

NORMAL OPERATION

8

 

 

heat is manually activated by pressing the read HEAT button for

four seconds. To activate Emergency Heat, press the red HEAT

button for four seconds. If your system is a heat pump with

electric heat, then the display will show the three choices:

SYSTEM IN CONTROL (the system will choose the type and

amount of heat needed for conditions)

HEAT PUMP ONLY (only the heat pump will be used for heating)

ELECTRIC HEAT ONLY (only electric heat will be used for

heating)

If your system is a Hybrid Heat™ system (heat pump with gas or

oil furnace), then the display will show the three choices:

HYBRID HEAT™ (the system will choose the type and amount of

heat needed for conditions)

FURNACE ONLY (only the furnace will be used for heating)

HEAT PUMP ONLY (only the heat pump will be used for heating)

Scroll the highlight to your choice using the scroll button under

the door, then press the left side button to save your selection

and exit.

To deactivate Emergency Heat, press the red HEAT button for four

seconds and choose SYSTEM IN CONTROL or HYBRID HEAT,

depending on your type of heating equipment.

Cooling

To select cooling, press the blue COOL button.

Cooling is confirmed when the blue LED adja-

cent to the blue COOL button is lit. Cooling is

operating when the blue LED is gradually puls-

ing on and off. (The LEDs can be turned off.

For details, see ADVANCED SETUP – LIGHT-

Loading...