Carrier HRVCCLHA, HRVCCLVU, HRVCCSVA, HRVCCSVU, HRVCCSHA User Manual

0 (0)
Carrier HRVCCLHA, HRVCCLVU, HRVCCSVA, HRVCCSVU, HRVCCSHA User Manual

HRVCCLHA, HRVCCSVU, HRVCCLVU

HRVCCSVA, HRVCCSHA

HEAT RECOVERY VENTILATOR

Owner’s Information Manual

HRVCCLHA Conventional Unit

HRVCCSVU Compact Unit

HRVCCLVU High Efficiency Unit

HRVCCSVA Unit (Top Port)

HRVCCSHA Unit (Side Port)

Fig. 1 - Heat Recovery Ventilators

NOTE TO EQUIPMENT OWNER:

For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.

HEAT RECOVERY VENTILATOR

Model # _____________________________________

Serial # ______________________________________

ACCESSORIES (List type and model #)

_____________________________________________

_____________________________________________

INSTALLATION INFORMATION:

Date Installed ________________________________

DEALERSHIP CONTACT INFORMATION:

Company Name_______________________________

Address______________________________________

_____________________________________________

Phone Number _______________________________

NOTE TO INSTALLER:

This manual must be left with the equipment owner.

1

 

80

70

 

 

 

 

60

AIR EXCHANGE

ON

 

 

 

 

 

ECHANGE´

D´AIR

MARCHE

 

 

 

50

 

 

OFF LOW HIGH

 

 

 

 

MAX

 

 

40

 

 

 

 

 

 

 

MIN

 

 

 

 

 

INTERMITTENT

20

30

 

 

 

 

25

 

 

 

 

 

 

 

 

 

% D´ HUMIDITE´ RELATIVE HUMIDITY

 

 

 

 

 

OFF

LOW

ARRET

BASSE HAUTE

 

ARRET

BASSE

 

 

 

INTERMITTENT

 

% HUM. RELATIVE HUM.

EXT. TEMP. EXT.

 

 

 

 

55%

10°C/50°F

 

 

 

 

45%

0°C/32°F

 

 

 

 

35%

–10°C/14°F

 

 

 

 

30%

–20°C/–4°F

 

 

 

 

 

MODE

AIR EXCHANGE

 

 

 

ECHANGE´ D´AIR

 

 

 

 

% HUM. RELATIVE HUM.

EXT. TEMP. EXT.

50

40

55%

10°C/50°F

45%

0°C/32°F

60

30

35%

–10°C/14°F

 

 

30%

–20°C/–4°F

70

 

25

 

80

 

20

 

 

 

 

% D´HUMIDITE RELATIVE HUMIDITY

OneTouchTM Control

Basic Control

Standard Control

Automatic Control

 

 

 

(Not compatible with the following series:

 

 

 

HRVCCSHA and HRVCCSVA)

 

 

Fig. 2 - Controls

A05360

 

 

 

SAFETY CONSIDERATIONS

Recognize safety information. This is the safety-alert symbol ! When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.

Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

OPERATING YOUR HEAT RECOVERY

VENTILATOR (HRV) WITH ONETOUCHt CONTROL:

Press “PUSH” until the desired ventilation operation is selected. There are three selections: High, Low, Intermittent. The power indicator light indicates which mode has been selected.

High: This mode is recommended for the removal of excess pollutants and humidity. The ventilator will operate at its maximum speed continuously. The power indicator light will be lit red when this mode is selected.

Low: This mode is recommended for normal daily operation. The ventilator will operate at its minimum speed continuously. The power indicator light will be lit yellow when this mode is selected.

Intermittent: This mode is recommended when the inside air is too dry in the heating season or too humid in the cooling season. The ventilator will operate at its minimum speed for 20 minutes per hour and be off for 40 minutes per hour. The power indicator light will be lit green when this mode is selected.

Off: To turn the ventilator off, press “Push” until the power indicator light is turned off.

OPERATING YOUR HEAT RECOVERY VENTILATOR (HRV) WITH BASIC, STANDARD AND AUTOMATIC CONTROL

Your HRV is designed to operate as an integral part of your total heating and cooling system. With the exception of high capacity models, which are available with standard controls only, all HRVs offer 4 control options (See Fig. 2).

SBasic Controls: Allow the user to manually set the unit to lowor high-fan speed as required to maximize comfort. Controls may be unit mounted.

SStandard Controls: Offer automatic dehumidistat control and the option to select low speed or intermittent fan during heating season.

SAutomatic Controls: In addition to the operational features found with standard controls, automatic controls feature a recirculation mode. Not for use with forced-air HVAC systems.

Fan Speed Control—Enables user to modulate fan speed from low to high.

Dehumidistat Control—Allows the user to select the relative humidity level at which the unit would change fan speed to avoid condensation problems while heating during the winter months. (See Table 1).

Continuous Mode—If the relative humidity inside the building is lower than selected, air exchange would occur with the outside at low speed. If the relative humidity level inside the building is higher than selected, air exchange would occur outside at high speed. This ensures continuous air exchange for constant air quality.

Intermittent Mode—If the relative humidity inside the building is lower than selected, no air exchange would occur, and the system would turn off. If the relative humidity inside the building is higher than selected, air exchange would occur with outside at high speed. This ensures minimum air exchange level when the building is unoccupied to minimize operating cost.

Recirculation Mode—If the relative humidity inside the building is lower than selected, indoor air would be circulated and filtered at high speed. If the relative humidity inside the house is higher an selected, air exchange would occur with outside at high speed. This ensures continuous movement and filtration of air for maximum comfort.

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before servicing system, always turn off main power to system. Turn off accessory heater power if applicable. There may be more than 1 disconnect switch.

2