Carrier 48A3, 48A2 User Manual

0 (0)

48A2,A3,A4,A5020-060 Single-Package Rooftop Gas Heating/Electric Cooling Units

with COMFORTLINK™ Controls and Scroll Compressors

User’s Information Manual

NOTE TO INSTALLER

This manual should be left with the equipment owner.

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

TO LIGHT UNIT

DANGER

1.Do not turn off the electrical power to unit without first turning off the gas supply.

2.Before attempting to start the gas heating section, familiarize yourself with all the procedures that must be followed.

3.Never attempt to manually light the burners on the unit with a match, lighter, or any other flame. If the electric sparking device fails to light the burners, refer to the shutdown procedures, then call your dealer as soon as possible.

If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, injury, or loss of life.

See Fig. 1 and 2 for location of gas valve. Refer to Fig. 3 while performing the following steps.

1.Disable unit operation by using the scrolling marquee. The scrolling marquee is located in the control box at the compressor end of the unit.

a.Push the ESCAPE key unit a blank display screen is shown.

b.Push the key until the SERVICE TEST LED is lit.

c.Push the ENTER key. The display will show STOP.

NOTE: Items in the Configuration and Service Test modes are password protected. The display will flash PASS and WORD when required. Use

the ENTER and arrow keys to enter the 4 digits of the password. The default password is 1111.

d.Push the ENTER key again. The NO/YES display will flash.

WARNING

Before performing recommended maintenance, be sure main power switch to unit is turned off and lockout tag is installed. Electrical shock could cause personal injury.

Your combination heating/cooling unit is equipped with direct spark ignition and induced draft power combustion blower.

WARNING

Burners will light automatically. Do not attempt to light by hand; personal injury may result.

e.Push the or key to toggle the display to YES and then push ENTER . The unit will be locked off from heating, cooling or any operation. The controls will still function and the display will still operate.

2.Close the field-installed manual gas shutoff valve.

3.Turn off the electrical power to the unit using the optional disconnect or the field-installed disconnect and lock off using proper lockout and tag-out procedures.

4.Remove the gas section panels.

5.Move the switch on the gas valve to the OFF position and wait 5 minutes.

NOTE: If this is the first installation of the unit, the gas flue hoods must be installed before operating unit. These must be installed for the unit to run properly.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

1

Catalog No. 04-53480052-01

Printed in U.S.A.

Form 48A-5SO

Pg 1

3-08

Replaces: 48A-3SO

Tab

1a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Carrier 48A3, 48A2 User Manual

 

GAS HEAT

GAS VALVE

SECTION

(PANEL REMOVED)

Fig. 1 — Typical Gas Section Location (48A3027 Shown)

Fig. 2 — Typical Gas Valve Location (48A2,A3,A4,A5020-050 Shown)

2

MODE

Run Status

Service Test

Temperature

Pressures

Setpoints

Inputs

Outputs

Configuration

Time Clock

Operating Modes

Alarms

a30-2239ef

Alarm Status

ESCAPE ENTER

STEP 1

STEP 4

STEP 6

a48-930tf

STEP 8

a48-925tf

a48-

STEP 2

STEP 3

a48-3767tf

STEP 5

a48-3768tf

STEP 7

 

MODE

a30-2239ef

 

Run Status

 

Service Test

 

 

Temperature

 

 

Pressures

 

 

Setpoints

 

 

Inputs

Alarm Status

 

Outputs

ESCAPE ENTER

 

Configuration

 

 

a48-

Time Clock

 

Operating Modes

 

 

Alarms

 

STEP 9

 

STEP 10

Fig. 3 — To Light Unit

3